SU-F-T-173: One-Scan Protocol: Verifying the Delivery of Spot-Scanning Proton Beam

Purpose: Radiochromic film for spot-scanning QA provides high spatial resolution and efficiency gains from one-shot irradiation for multiple depths. However, calibration can be a tedious procedure which may limit widespread use. Moreover, since there may be an energy dependence, which manifests as a depth dependence, this may require additional measurements for each patient. We present a one-scan protocol to simplify the procedure. Methods: We performed the calibration using an EBT3 film at depths of 18, 20, 24cm of Plastic Water exposed by a 6-level step-wedge plan on a Proteus Plus proton system (IBA, Belgium). The calibration doses ranged 65–250 cGy(RBE) for proton energies of 170–200MeV. A clinical prostate+nodes plan was used for validation. The planar doses at selected depths were measured with EBT3 films and analyzed using one-scan protocol (one-scan digitization of QA film and at least one film exposed to known dose). The Gamma passing rates, dose-difference maps, and profiles of 2D planar doses measured with EBT3 film, IBA MatriXX PT, versus TPS calculations were analyzed and compared. Results: The EBT3 film measurement results matched well with the TPS calculation data with an average passing rate of ∼95% for 2%/2mm and slightly lower passing rates were obtained from an ion chamber array detector. We were able to demonstrate that the use of a proton step-wedge provided clinically acceptable results and minimized variations between film-scanner orientation, inter-scan, and scanning conditions. Furthermore, it could be derived from no more than two films exposed to known doses (one could be zero) for rescaling the master calibration curve at each depth. Conclusion: The use of a proton step-wedge for calibration of EBT3 film increases efficiency. The sensitivity of the calibration to depth variations has been explored. One-scan protocol results appear to be comparable to that of the ion chamber array detector. One author has a research grant from Ashland Inc., the manufacturer of the GafChromic film.

60 APPLIED LIFE SCIENCES↗

SU-F-T-226: QA Management for a Large Institution with Multiple Campuses for FMEA

Purpose: To redesign our radiation therapy QA program with the goal to improve quality, efficiency, and consistency among a growing number of campuses at a large institution. Methods: A QA committee was established with at least one physicist representing each of our six campuses (22 linacs). Weekly meetings were scheduled to advise on and update current procedures, to review end-to-end and other test results, and to prepare composite reports for internal and external audits. QA procedures for treatment and imaging equipment were derived from TG Reports 142 and 66, practice guidelines, and feedback from ACR evaluations. The committee focused on reaching a consensus on a single QA program among all campuses using the same type of equipment and reference data. Since the recommendations for tolerances referenced to baseline data were subject to interpretation in some instances, the committee reviewed the characteristics of all machines and quantified any variations before choosing between treatment planning system (i.e. treatment planning system commissioning data that is representative for all machines) or machine-specific values (i.e. commissioning data of the individual machines) as baseline data. Results: The configured QA program will be followed strictly by all campuses. Inventory of available equipment has been compiled, and additional equipment acquisitions for the QA program are made as needed. Dosimetric characteristics are evaluated for all machines using the same methods to ensure consistency of beam data where possible. In most cases, baseline data refer to treatment planning system commissioning data but machine-specific values are used as reference where it is deemed appropriate. Conclusion: With a uniform QA scheme, variations in QA procedures are kept to a minimum. With a centralized database, data collection and analysis are simplified. This program will facilitate uniformity in patient treatments and analysis of large amounts of QA data campus-wide, which will ultimately facilitate FMEA.

43 PARTICLE ACCELERATORS↗

SU-G-TeP2-01: Can EPID Based Measurement Replace Traditional Daily Output QA On Megavoltage Linac?

Purpose: To investigate the long term stability and viability of using EPID-based daily output QA via in-house and vendor driven protocol, to replace conventional QA tools and improve QA efficiency. Methods: Two Varian TrueBeam machines (TB1&TB2) equipped with electronic portal imaging devices (EPID) were employed in this study. Both machines were calibrated per TG-51 and used clinically since Oct 2014. Daily output measurement for 6/15 MV beams were obtained using SunNuclear DailyQA3 device as part of morning QA. In addition, in-house protocol was implemented for EPID output measurement (10×10 cm fields, 100 MU, 100cm SID, output defined over an ROI of 2×2 cm around central axis). Moreover, the Varian Machine Performance Check (MPC) was used on both machines to measure machine output. The EPID and DailyQA3 based measurements of the relative machine output were compared and cross-correlated with monthly machine output as measured by an A12 Exradin 0.65cc Ion Chamber (IC) serving as ground truth. The results were correlated using Pearson test. Results: The correlations among DailyQA3, in-house EPID and Varian MPC output measurements, with the IC for 6/15 MV were similar for TB1 (0.83–0.95) and TB2 (0.55–0.67). The machine output for the 6/15MV beams on both machines showed a similar trend, namely an increase over time as indicated by all measurements, requiring a machine recalibration after 6 months. This drift is due to a known issue with pressurized monitor chamber which tends to leak over time. MPC failed occasionally but passed when repeated. Conclusion: The results indicate that the use of EPID for daily output measurements has the potential to become a viable and efficient tool for daily routine LINAC QA, thus eliminating weather (T,P) and human setup variability and increasing efficiency of the QA process.

60 APPLIED LIFE SCIENCES↗

SU-E-T-328: Dosimetric Impact of Cobalt-Chrome Stabilization Hardware in Paraspinal Radiation Therapy

Purpose: Due to saturation, high density materials Result in an apparent density of 3.2 g/cm{sup 3} in CT images. The true density of traditional titanium stabilization rods (∼4.4 g/cm{sup 3}) is typically ignored in treatment planning. This may not be acceptable for new cobalt-chrome rods with a density of 8.5 g/cm{sup 3}. This study reports the dosimetric impact of cobalt-chrome rods in paraspinal radiotherapy. Methods: For titanium and cobalt-chrome rods, two planning studies were done for both IMRT and VMAT in Varian Eclipse using AAA. 1) The effect of planning without assigning the true rod density was assessed by comparing plans generated with the apparent density and recalculated with the true density for titanium and cobalt-chrome. 2) To test if TPS can compensate for high density rods during optimization. Furthermore, TPS calculation accuracy was verified using MapCheck for a single 20 x 10 cm{sup 2} field. The MapCheck was incrementally shifted to achieve measurement resolution of 1 mm. Results: PTV coverage was ∼0.3% and ∼4.7% lower in plans that were recalculated with the true rod density of titanium and cobalt-chrome, respectively. PTV coverage can be maintained if the correct density is used in optimization. Measurements showed that TPS overestimated the dose locally by up to 11% for cobalt-chrome rods and up to 4% for titanium rods if the density is incorrect. With density corrected, maximum local differences of 6% and 3% were seen for cobalt-chrome and titanium rods, respectively. At 2 cm beneath a rod, electrons scattered from the side of the rod increased the lateral dose and diminished as depth increases. TPS was not able to account for this effect properly even with the true rod density assigned. Conclusion: Neglecting the true density of cobalt-chrome rods can cause under coverage to the PTV. Assigning the correct density during treatment planning can minimize unexpected decrease in PTV dose.

60 APPLIED LIFE SCIENCES↗

SU-E-T-52: Beam Data Comparison for 20 Linear Accelerators in One Network

Purpose: To compare photon beam data for the 20 Varian linear accelerators (TrueBeam, iX, and EX models) in use at five centers in the same network with the intent to model with one set of beam data in Eclipsec. Methods: Varian linear accelerators, TrueBeam (3), 21 EX, iX, and Trilogy (14), and 6 EX (3), installed between 1999 and 2014 have their 6 MV and 15 MV x-ray beams reevaluated. Full commissioning, including output factors (St), percent depth doses (PDD), and off-axis profiles, was recently performed for a TrueBeam with a cc04 ion chamber in an IBA Blue phantom. Similarly, a subset of beam data for each of the other accelerators was measured recently as follows: for 3×3, 10×10, and 30×30 cm{sup 2} field sizes, flatness and penumbra (80–20%) were measured at dmax and 10 cm depths, PDD were measured at 10 and 20 cm depths, and St were measured at 5 cm depth. Measurement results for all machines were compared. Results: For 15 high-energy (6 and 15 MV) and 3 low-energy machines (6MV only): 1) PDD agreed within 1.4% at 10 and 20 cm depths; 2) penumbra agreed within 1.0 mm at dmax and 10 cm depths; 3) flatness was within 1.3% at dmax and 10 cm depths; and 4) with exception of the three low energy machines, output factors were within 1.1% and 0.5% for 3×3 and 30×30 cm{sup 2}, respectively. Measurement uncertainty, not quantified here, accounts for some of these differences. Conclusion: Measured beam data from 15 high-energy Varian linacs are consistent enough that they can be classified using one beam data set in Eclipse. Two additional high-energy machines are removed from this group until their data are further confirmed. Three low-energy machines will be in a separate class based upon differences in output factors (St)

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-440: Elliptical Source Model for IMRT and VMAT with Complex Modulation

Purpose: To improve dose calculation accuracy for highly modulated fields in IMRT and VMAT using an elliptical source model. Methods: For 2 TrueBeam linacs equipped with Millennium and HD MLCs, the source model of 6 and 15 MV beams was optimized with adjustments of the focal spot dimensions in the Varian Eclipse TPS. Starting from the measured focal spot size of 1.75 × 1.75 mm, the y-dimension of the source was varied while the x-dimension was kept constant. In addition, all other modeling parameters such as the extrafocal source and dosimetric leaf gap remained unchanged. The different models were compared with measured penumbra for jaws and MLC using ion chamber and diode. For 2 IMRT and 2 VMAT cases, the calculated doses were compared with radiochromic film and EPID measurements. Results: A source size of 1.75 × 0.75 mm was found to be optimal for beam modeling. The calculated penumbra (80–20) of a MLCdefined open field was within 0.8 mm compare to measurement for both the inline and crossline profile for various field sizes and depths. The dose gradients in the direction perpendicular to the MLC travel direction was better modeled compared to the source model with a circular focal spot of 1.75 mm for the fields with rigorous MLC modulation. Local differences up to 8% were found in those regions. Conclusion: The conventional source model using a symmetric focal spot tends to overestimate the penumbra perpendicular to the MLC travel direction, resulting in an inaccurate dose calculation especially for fields with complex MLC modulation. This can be improved with an elliptical source model and it can be considered as a standard as IMRT and VMAT treatments are becoming a norm for the clinic.

60 APPLIED LIFE SCIENCES↗

Structural basis of RNA recognition and activation by innate immune receptor RIG-I

Retinoic-acid-inducible gene-I (RIG-I; also known as DDX58) is a cytoplasmic pathogen recognition receptor that recognizes pathogen-associated molecular pattern (PAMP) motifs to differentiate between viral and cellular RNAs. RIG-I is activated by blunt-ended double-stranded (ds)RNA with or without a 5'-triphosphate (ppp), by single-stranded RNA marked by a 5'-ppp and by polyuridine sequences. Upon binding to such PAMP motifs, RIG-I initiates a signalling cascade that induces innate immune defences and inflammatory cytokines to establish an antiviral state. The RIG-I pathway is highly regulated and aberrant signalling leads to apoptosis, altered cell differentiation, inflammation, autoimmune diseases and cancer. The helicase and repressor domains (RD) of RIG-I recognize dsRNA and 5'-ppp RNA to activate the two amino-terminal caspase recruitment domains (CARDs) for signalling. Here, to understand the synergy between the helicase and the RD for RNA binding, and the contribution of ATP hydrolysis to RIG-I activation, we determined the structure of human RIG-I helicase-RD in complex with dsRNA and an ATP analogue. The helicase-RD organizes into a ring around dsRNA, capping one end, while contacting both strands using previously uncharacterized motifs to recognize dsRNA. Small-angle X-ray scattering, limited proteolysis and differential scanning fluorimetry indicate that RIG-I is in an extended and flexible conformation that compacts upon binding RNA. These results provide a detailed view of the role of helicase in dsRNA recognition, the synergy between the RD and the helicase for RNA binding and the organization of full-length RIG-I bound to dsRNA, and provide evidence of a conformational change upon RNA binding. The RIG-I helicase-RD structure is consistent with dsRNA translocation without unwinding and cooperative binding to RNA. The structure yields unprecedented insight into innate immunity and has a broader impact on other areas of biology, including RNA interference and DNA repair, which utilize homologous helicase domains within DICER and FANCM.

59 BASIC BIOLOGICAL SCIENCES↗

Residual Stress Characterization of Al/SiC Nanoscale Multilayers using X-ray

Nanolayered composites are used in a variety of applications such as wear resistant coatings, thermal barrier coatings, optical and magnetic thin films, and biological coatings. Residual stresses produced in these materials during processing play an important role in controlling their microstructure and properties. In this paper, we have studied the residual stresses in model metal-ceramic Al/SiC nanoscale multilayers produced by physical vapor deposition (magnetron sputtering). X-ray synchrotron radiation was used to measure stresses in the multilayers using the sin{sup 2} {psi} technique. The stresses were evaluated as a function of layer thicknesses of Al and SiC and also as a function of the number of layers. The stress state of Al in the multilayer was largely compressive, compared to single layer Al stresses. This is attributed to a peening mechanism due to bombardment of the Al layers by SiC and Ar neutrals during deposition. The stress evolution was numerically modeled by a simplified peening process to qualitatively explain the Al thickness-dependent residual stresses.

36 MATERIALS SCIENCE↗

Residual stress characterization of Al/SiC nanoscale multilayers using X-ray

Nanolayered composites are used in a variety of applications such as wear resistant coatings, thermal barrier coatings, optical and magnetic thin films, and biological coatings. Residual stresses produced in these materials during processing play an important role in controlling their microstructure and properties. In this paper, we have studied the residual stresses in model metal-ceramic Al/SiC nanoscale multilayers produced by physical vapor deposition (magnetron sputtering). X-ray synchrotron radiation was used to measure stresses in the multilayers using the sin{sup 2} {Psi} technique. The stresses were evaluated as a function of layer thicknesses of Al and SiC and also as a function of the number of layers. The stress state of Al in the multilayer was largely compressive, compared to single layer Al stresses. This is attributed to a peening mechanism due to bombardment of the Al layers by SiC and Ar neutrals during deposition. The stress evolution was numerically modeled by a simplified peening process to qualitatively explain the Al thickness-dependent residual stresses.

36 MATERIALS SCIENCE↗