Search NASA⌕ Search

Engineering topics

Tang, Kexin

Publications and source records attributed to Tang, Kexin.

Optimal conditions for efficient flow-electrode capacitive deionization

One of the current barriers to achieving fast and stable performance for flow-electrode capacitive deionization (FCDI) is determining optimal operating parameters. To date, however, no consensus has been reached for universal conditions for FCDI. Through experimental and modeling approaches in this study, we systematically evaluated the influence of applied potential (V = 1.2–2.4 V) and electrolyte concentration (C0 = 0.05–0.5 M) on the FCDI and electrodialysis (ED) desalination processes. Evaluation indicators include the concentration decrease in the desalinated solution, salt removal rates, pH fluctuations, charge efficiency, and energy consumption. Results demonstrated that the dynamic curves of concentration decrease at 2.0 V nearly overlapped with the response at 1.6 V at certain electrolyte concentrations, while the salt removal rates at 0.2 M salt concentration were the best among all concentrations tested at a range of applied potential. Therefore, it was thus concluded that the optimum conditions for FCDI operation are 1.6 V applied potential and 0.2 M initial salt concentration, under which faradaic reactions are not being triggered, and concentration polarization does not significantly affect ion transfer. Furthermore, a comparative study between FCDI and ED indicated that ED has a different dependence on the electrolyte concentration and applied potential, in which the desalination can be linearly enhanced with increasing potential but greatly limited at high concentrations. Due to the presence of carbon particles in FCDI, the enhanced charge/ion transfer is probably the main reason for the different desalination performance of FCDI and ED. Overall, the optimal operating parameters obtained in this work could be used as basic test conditions for further development of new carbon-based materials for FCDI.

42 ENGINEERING↗

Enhanced Water Desalination by Increasing the Electroconductivity of Carbon Powders for High-Performance Flow-Electrode Capacitive Deionization

Flow-electrode capacitive deionization (FCDI) can be improved via enhanced charge transfer by increasing the flow-electrode (FE) conductivity. Since water is the main component of FE (>70%), the key to improving the electroconductivity lies in the properties of carbon materials. In this work, three types of carbon powders, i.e., activated carbon (AC), mesoporous carbon, and carbon nanotubes (CNTs), were employed in FEs to investigate the influence of powder properties on the FCDI performance. The morphology and structure of powders and electrochemical behavior and rheology of FEs were investigated to reveal the relationship between FE properties and desalination performance. Results show that, due to their unique electrosorption behavior, excellent conductivity, and enhanced conductivity through a bridging effect, CNT-based FE (carbon loading: 3 wt %) achieved the fastest (8.3 mg s–1 m–2) and the most stable desalination (charge efficiency: 93.3%). A faster desalination (13.2 mg s–1 m–2), due to significantly improved electroconductivity (13.2 times) with only a slight viscosity increase (1.1 times), was achieved by adding CNTs into 6.91 wt % AC-based FE for a 7.41 wt % total carbon concentration. This study highlights the importance of the intrinsic properties of carbon materials, especially electroconductivity, in promoting FCDI desalination performance.

36 MATERIALS SCIENCE↗

Seawater desalination by over-potential membrane capacitive deionization: Opportunities and hurdles

The salt removal capacity ( SRC ) of the carbon electrodes in membrane capacitive deionization (MCDI) is limited by the applied potential (<1.6 V). Thus, enhancement of the SRC is essential before applying MCDI to seawater desalination. This study aims at developing a novel MCDI system for seawater desalination by applying over-potential (OP) to enhance ion-adsorption capacity and kinetics, and by reversing the polarity (RP) of electrodes to improve ion-desorption kinetics (hereafter named OP-MCDI-RP) for seawater desalination. At 2.4 V, the OP-MCDI system with mesoporous carbon demonstrated a SRC value of 64.7 mg g –1 when desalting 0.5 M NaCl solution, while the OP-CDI system could only remove 8.2 mg g –1 under identical conditions. Similarly, an OP-MCDI cell using carbon aerogel demonstrated a greater SRC value of 43.4 mg g –1 in comparison with 12.5 mg g –1 achieved in OP-CDI. These results indicate that the OP-MCDI system can directly desalt high salinity water regardless of the electrode material. In contrast to the OP-MCDI system, the OP-MCDI-RP system yields a higher regeneration efficiency by applying a reversed low-voltage. It is shown that, under appropriate operating conditions, the OP-MCDI-RP system reduced the electrical conductivity of a seawater sample of 37 practical salinity units by 99.9%, suggesting that the OP-MCDI-RP system can be employed for seawater desalination. In conclusion, due to the dramatic increase in energy demand and insufficient long-term stability caused by high potential and high salt concentration, however, the OP-MCDI-RP process should be further investigated for potential practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗