Passive Tamper Indicating Enclosures Incorporating Embedded Optical Fibre

AWE and PNNL are engaged in a technical collaboration investigating techniques to enhance continuity of knowledge over Accountable Items within a verified nuclear weapons dismantlement process. Tamper Indicating Enclosures (TIE) will likely be deployed as part of a chain of custody regime to indicate an unauthorised attempt to access an Accountable Item. This paper looks at the use of passive TIEs incorporating embedded optical fibre; concepts relating to deployment, tamper indication and unique identification will be discussed.

continuity of knowledge↗

An Optically Stimulated Luminescence Uranium Enrichment Monitor

The Pacific Northwest National Laboratory (PNNL) has pioneered the use of Optically Stimulated Luminescence (OSL) technology for use in personnel dosimetry and high dose radiation processing dosimetry. PNNL has developed and patented an alumina-based OSL dosimeter that is being used by the majority of medical X-ray and imaging technicians worldwide. PNNL has conceived of using OSL technology to passively measure the level of UF6 enrichment by attaching the prototype OSL monitor to pipes containing UF6 gas within an enrichment facility. The prototype OSL UF6 monitor utilizes a two-element approach with the first element open and unfiltered to measure both the low energy and high energy gammas from the UF6, while the second element utilizes a 3-mm thick tungsten filter to eliminate the low energy gammas and pass only the high energy gammas from the UF6. By placing a control monitor in the room away from the UF6 pipes and other ionizing radiation sources, the control readings can be subtracted from the UF6 pipe monitor measurements. The ratio of the shielded to the unshielded net measurements provides a means to estimate the level of uranium enrichment. PNNL has replaced the commercially available MicroStar alumina-based dosimeter elements with a composite of polyethylene plastic, high-Z glass powder, and BaFBr:Eu OSL phosphor powder at various concentrations. The high-Z glass was added in an attempt to raise the average “Z” of the composite dosimeter and increase the response. Additionally, since BaFBr:Eu OSL phosphor is optimally excited and emits light at different wavelengths compared to alumina, the commercially available MicroStar reader was modified for reading BaFBr:Eu in a parallel effort to increase reader sensitivity. PNNL will present the design and performance of our novel OSL uranium enrichment monitor based on a combination of laboratory and UF6 test loop measurements. PNNL will also report on the optimization effort to achieve the highest possible performance from both the OSL enrichment monitor and the new custom OSL reader modified for this application. This project has been supported by the US Department of Energy’s National Nuclear Security Administration’s Office of Dismantlement and Transparency (DOE/NNSA/NA-241).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Autoradiography Using OSL for Monitoring Warhead Dismantlement

The use of radiation imaging techniques to provide increased confidence in a dismantlement verification regime is still under investigation. Currently, radiation measurements can be used to confirm attributes such as the presence, quality, and mass of containerized nuclear material. However, imaging techniques can be used to confirm the shape, size, and/or symmetry of the object being interrogated. Imaging can be used as a complementary technique to radiation measurements to confirm a declaration or as a chain of custody measure to confirm that an item has not been tampered with. As with other attribute measurements, the image data must be protected behind an information barrier and analyzed to give an unclassified result when compared to an agreed upon threshold. This paper will discuss the use of Optically Stimulated Luminescence to perform autoradiography of sources using coded apertures to differentiate between point sources and various distributed sources. The coded aperture chosen for this application is based on modified uniform redundant arrays (mURAs) which resulted in the design and manufacture of an efficient, high-resolution mURA mask/antimask system. The potential use of the autoradiography technique with the coded aperture as an intrinsic information barrier and the required protection of the mask and unfolding algorithm will also be discussed. This project has been supported by the US Department of Energy’s National Nuclear Security Administration’s Office of Dismantlement and Transparency (DOE/NNSA/NA-241).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Seal Wire Integrity Verification Instrument: Evaluation of Laboratory Prototypes

Tamper indicating devices (TIDs) provide evidence that sensitive items, to which they have been applied, have been tampered with or not. Passive wire-loop seals, a class of TIDs, are generally comprised of a multi-strand seal wire that is threaded through or around key features and a unique seal body that captures and restrains the seal wire. Seal integrity resides with unique identification of the seal and the integrity of the seal body and the seal wire. Upon inspection, the seal wire may be cut and the full length inspected. A new seal may be applied in the field as a replacement, if desired. Seal wire inspection typically requires visual and tactile examinations, which are both subjective. A need therefore exists to develop seal wire inspection technology that is easy to use in the field, is objective, provides an auditable data trail, and has low error rates. Expected benefits, if successfully implemented, are improved on-site inspection reliability and security. The work scope for this effort was restricted to integrity of seal wire used by the International Atomic Energy Agency (IAEA) and resulted in development of a wire integrity verification instrument (WIVI) laboratory prototype. Work included a performance evaluation of a laboratory-bench-top system, and design and delivery of two WIVI laboratory prototypes. The paper describes the basic physics of the eddy current measurement, a description of the WIVI laboratory prototype, and an initial evaluation performed by IAEA personnel. --- Funding was provided by the U.S. Program for Technical Assistance to IAEA Safeguards (POTAS).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Container Verification Using Optically Stimulated Luminescence

Containment verification is a high priority for safeguards containment and surveillance. Nuclear material containers, safeguards equipment cabinets, camera housings, and detector cable conduit are all vulnerable to tampering. Even with a high security seal on a lid or door, custom-built hinges and interfaces, and special colors and types of finishes, the surfaces of enclosures can be tampered with and any penetrations repaired and covered over. With today’s technology, these repairs would not be detected during a simple visual inspection. Several suggested solutions have been to develop complicated networks of wires, fiber-optic cables, lasers or other sensors that line the inside of a container and alarm when the network is disturbed. This results in an active system with real time evidence of tampering but is probably not practical for most safeguards applications. A more practical solution would be to use a passive approach where an additional security feature was added to surfaces which would consist of a special coating or paint applied to the container or enclosure. One type of coating would incorporate optically stimulated luminescent (OSL) material. OSL materials are phosphors that luminesce in proportion to the ionizing radiation dose when stimulated with the appropriate optical wavelengths. The OSL fluoresces at a very specific wavelength when illuminated at another, very specific wavelength. The presence of the pre-irradiated OSL material in the coating is confirmed using a device that interrogates the surface of the enclosure using the appropriate optical wavelength and then reads the resulting luminescence. The presence of the OSL indicates that the integrity of the surface is intact. The coating itself could be transparent which would allow the appearance of the container to remain unchanged or the OSL material could be incorporated into certain paints or epoxies used on various types of containers. The coating could be applied during manufacturing, before deployment, or even after the enclosure is already in the field. This presentation will present some preliminary investigations into the use of OSL as an inexpensive, easy to implement, containment verification technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗