Search NASA⌕ Search

Engineering topics

Tantawi, Sami

Publications and source records attributed to Tantawi, Sami.

At least 19 records

Improving Cathode Testing with a High-Gradient Cryogenic Normal Conducting RF Photogun

Future electron accelerator applications such as X-ray free electron lasers and colliders are dependent on significantly increasing beam brightness. With the observation that linac beam manipulation’s best preservation of max brightness is at the cathode, we are incentivized to create an environment where we can study how to achieve the highest possible photogun brightness. In order to do so, we intend to extract beams from high-brightness photocathodes with the highest achievable accelerating gradients we can manage in a klystron-powered radiofrequency (RF) photogun. We utilize here cryogenic normal conducting cavities to achieve ultra-high gradients via limitation of breakdown rates (BDR). The low temperatures should also reduce cathode emittance by reducing the mean transverse energy (MTE) of electrons near the photoemission threshold. To this end, we have designed and produced a new CrYogenic Brightness-Optimized Radiofrequency Gun (CYBORG) for use in a new beamline at UCLA. We will introduce the enabling RF and photoemission physics as a primer for the new regime of high field low temperature cathodes we intend to enter. We further report the current status of the beamline commissioning, including the cooling of the photogun to 100 K, and producing 0.5 MW of RF feed power, which corresponds to cathode accelerating fields in the range of 80–90 MV/m. We further plan iterative improvements to both to 77 K and 1 MW corresponding to our ultimate goal >120 MV/m. Our discussion will include future beamline tests and the consideration of the initial realization of an ultra-high-gradient photoinjector concept.

Lawler, Gerard Emile (ORCID:0000000160113435)↗

Shielding Analysis of a Preclinical Bremsstrahlung X-ray FLASH Radiotherapy System within a Clinical Radiation Therapy Vault

A preclinical radiotherapy system producing FLASH dose rates with 12 MV bremsstrahlung x rays is being developed at Stanford University and SLAC National Accelerator Laboratory. Because of the high expected workload of 6,800 Gy w –1 at the isocenter, an efficient shielding methodology is needed to protect operators and the public while the preclinical system is operated in a radiation therapy vault designed for 6 MV x rays. Here, in this study, an analysis is performed to assess the shielding of the local treatment head and radiation vault using the Monte Carlo code FLUKA and the empirical methodology given in the National Council on Radiation Protection and Measurements Report 151. Two different treatment head shielding designs were created to compare single-layer and multilayer shielding methodologies using high-Z and low-Z materials. The multilayered shielding methodology produced designs with a 17% reduction in neutron fluence leaking from the treatment head compared to the single layered design of the same size, resulting in a decreased effective dose to operators and the public. The conservative assumptions used in the empirical methods can lead to over-shielding when treatment heads use polyethylene or multilayered shielding. High-Z/Low-Z multilayered shielding optimized via Monte Carlo is shown to be effective in the case of treatment head shielding and provide more effective shielding design for external beam radiotherapy systems that use 12 MV bremsstrahlung photons. Modifications to empirical methods used in the assessment of MV radiotherapy systems may be warranted to capture the effects of polyethylene in treatment head shielding.

61 RADIATION PROTECTION AND DOSIMETRY↗

Status and future plans for C 3 R&D

C 3 is an opportunity to realize an e + e - collider for the study of the Higgs boson at √s = 250 GeV, with a well defined upgrade path to 550 GeV while staying on the same short facility footprint. C 3 is based on a fundamentally new approach to normal conducting linear accelerators that achieves both high gradient and high efficiency at relatively low cost. Given the advanced state of linear collider designs, the key system that requires technical maturation for C 3 is the main linac. This paper presents the staged approach towards a facility to demonstrate C 3 technology with both Direct (source and main linac) and Parallel (beam delivery, damping ring, ancillary component) R&D. The primary goal of the C 3 Demonstration R&D Plan is to reduce technical and cost risk by building and operating the key components of C 3 at an adequate scale. This R&D plan starts with the engineering design, and demonstration of one cryomodule and will culminate in the construction of a 3 cryomodule linac with pre-production prototypes. This R&D program would also demonstrate the linac rf fundamentals including achievable gradient and gradient stability over a full electron bunch train and breakdown rates. It will also investigate beam dynamics including energy spread, wakefields, and emittance growth. This work will be critical to confirm the suitability of the C 3 beam parameters for the physics reach and detector performance in preparation for a Conceptual Design Report (CDR), as well as for follow-on technology development and industrialization. The C 3 Demonstration R&D Plan will open up significant new scientific and technical opportunities based on development of high-gradient and high-efficiency accelerator technology. It will push this technology to operate both at the GeV scale and mature the technology to be reliable and provide high-brightness electron beams. The timeline for progressing with C 3 technology development will be governed by practical limitations on both the technical progress and resource availability. It consists of four stages: Stage 0) Ongoing fundamental R&D on structure prototypes, damping and vibrations. Stage 1) Advancing the engineering maturity of the design and developing start-to-end simulations including space-charge and wakefield effects. This stage will include testing of strucutres operating at cryogenic temperatures. Beam tests would be performed with high beam current to test full beam loading. Stage 2) Production and testing of the first cryomodule at cryogenic temperatures. This would provide sufficient experimental data to compile a CDR and it is anticipated for Stage 2 to last 3 years and to culminate with the transport of photo-electrons through the first cryomodule. Stage 3) Updates to the engineering design of the cryomodules, production of the second and third cryomodule and their installation. Lower charge and lower emittance beams will be used to investigate emittance growth. The successful full demonstration of the 3 cryomodules to deliver up to a 3 GeV beam and achieve the C 3 five gradient will allow a comprehensive and robust evaluation of the technical design of C 3 as well as mitigate technical, schedule, and cost risks required to proceed with a Technical Design Report (TDR).

radiation hardened magnets↗

Frontiers in the Application of RF Vacuum Electronics

The application of radio frequency (RF) vacuum electronics for the betterment of the human condition began soon after the invention of the first vacuum tubes in the 1920s and has not stopped since. Today, microwave vacuum devices are powering important applications in health treatment, material and biological science, wireless communication-terrestrial and space, Earth environment remote sensing, and the promise of safe, reliable, and inexhaustible energy. This article highlights some of the exciting application frontiers of vacuum electronics.

42 ENGINEERING↗

Monte Carlo simulation of shielding designs for a cabinet form factor preclinical MV–energy photon FLASH radiotherapy system

Purpose: A preclinical MV-energy photon FLASH radiotherapy system is being designed at Stanford and SLAC National Accelerator Laboratory. Because of the higher energy and dose rate compared to conventional kV-energy photon laboratory-scale irradiators, adequate shielding in a stand-alone cabinet form factor is more challenging to achieve. We present a Monte Carlo simulation of multilayered shielding for a compact self-shielding system without the need for a radiation therapy vault. Methods: A multilayered shielding approach using multiple alternating layers of high-Z and low-Z materials is applied to the self-shielded cabinet to effectively mitigate the secondary radiation produced and to allow the device to be housed in a Controlled Radiation Area outside of a radiation vault. The multilayered shielding approach takes advantage of the properties of high-Z and low-Z radiation shielding materials such as density, cross-section, atomic number of the shielding elements, and products of radiation interactions within each layer. The Monte Carlo radiation transport code, FLUKA, is used to simulate the total effective dose produced by the operation. Results: The multilayered shielding designs proposed and simulated produced effective dose rates significantly lower than monolayer designs with the same total material thickness at the regulatory boundary; this is accomplished through the manipulation of the locations where secondary radiation is produced and reactions due to material properties such as neutron back reflection in hydrogen. Borated polyethylene at 5 wt% significantly increased the shielding performance as compared to regular polyethylene, with the magnitude of the reduction depending upon the order of the shielding material. Conclusions: The multilayered shielding provides a path for shielding preclinical FLASH systems that deliver MV-energy bremsstrahlung photons. Furthermore, this approach promises to be more efficient with respect to the shielding material mass and space claim as compared to shielded vaults typically required for clinical radiation therapy with MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variational Self-Consistent Theory for Beam-Loaded Cavities

A new variational theory is presented for beam loading in microwave cavities. The beam{field interaction is formulated as a dynamical interaction whose stationarity according to Hamilton’s principle will naturally lead to steady-state solutions that indicate how a cavity’s resonant frequency, Q and optimal coupling coefficient will detune as a result of the beam loading. A driven cavity Lagrangian is derived from first principles, including the effects of cavity wall losses, input power and beam interaction. The general formulation is applied to a typical klystron input cavity to predict the appropriate detuning parameters required to maximize the gain (or modulation depth) in the average Lorentz factor boost, (Δ γ). Numerical examples are presented, showing agreement with the general detuning trends previously observed in the literature. The developed formulation carries several advantages for beam-loaded cavity structures. It provides a self-consistent model for the dynamical (nonlinear) beam{field interaction, a procedure for maximizing gain under beam-loading conditions, and a useful set of parameters to guide cavity-shape optimization during the design of beam-loaded systems. Enhanced clarity of the physical picture underlying the problem seems to be gained using this approach, allowing straightforward inclusion or exclusion of different field configurations in the calculation and expressing the final results in terms of measurable quantities. Two field configurations are discussed for the klystron input cavity, using finite magnetic confinement or no confinement at all. Formulating the problem in a language that is directly accessible to the powerful techniques found in Hamiltonian dynamics and canonical transformations may potentially carry an additional advantage in terms of analytical computational gains, under suitable conditions

43 PARTICLE ACCELERATORS↗

Fabrication and Tuning of a THz-Driven Electron Gun

We have developed a THz-driven field emission electron gun and beam characterization assembly. The two cell standing-wave gun operates in the pi mode at 110.08 GHz. It is designed to produce 360 keV electrons with 500 kW of input power supplied by a 110 GHz gyrotron. Multiple gun structures were electroformed in copper using a high precision diamond-turned mandrel. The field emission cathode is a rounded copper tip located in the first cell. The cavity resonances were mechanically tuned using azimuthal compression. This work will discuss details of the fabrication and tuning and present the results of low power measurements.

43 PARTICLE ACCELERATORS↗

A proton beam energy modulator for rapid proton therapy

We present the design for a rapid proton energy modulator with radiofrequency accelerator cavities, which can deliver the proton radiation dose to varied depth in human tissues much faster than traditional mechanical beam energy degraders. The proton energy modulator is designed as a multi-cell 1-m long accelerator working at 2.856 GHz. Each individual accelerator cavity is powered by a 400 kW compact klystron to provide an accelerating/decelerating gradient of 30 MV/m. The high gradient is enabled by the individual power coupling regime, which provides a high shunt impedance. Beam dynamics simulations were performed, showing that the energy modulator can provide ±30 MeV of beam energy change for a 150 MeV, 7 mm long (full length) proton bunch, and the total energy spread of 3 MeV is satisfactory to clinical needs. A prototype experiment of a single cell has been built and tested, and the low-power microwave measurement results agree very well with simulations. The energy modulator is optimized for the 150 MeV cyclotron proton beam, while this approach can work with different beam energies.

47 OTHER INSTRUMENTATION↗

Design and demonstration of a distributed-coupling linear accelerator structure

We present a topology for linear accelerators (linacs) in which the power is distributed to the cavities through a waveguide with periodic apertures that guarantees the correct phases and amplitudes along the structure length. Unlike conventional traveling and standing-wave linacs, the presented topology allows the cavity shapes to be designed without the constraints applied to the coupling between cells to transfer power from one cell to the next. Therefore, the topology permits more degrees of freedom for the optimization of individual cavity shapes in comparison with conventional linacs. The cavity shapes can be optimized for power consumption and efficiency, and/or the manipulation of the surface fields for high gradient operation. This topology also provides a possibility for low-temperature manufacturing techniques that prevent the annealing of the material during typical brazing processes; hence, the material could retain its original properties such as hardness. We present a design and an experimental demonstration of this linac.

43 PARTICLE ACCELERATORS↗

Experimental demonstration of externally driven millimeter-wave particle accelerator structure

We report the experimental demonstration of a mm-wave electron accelerating structure powered by a high-power rf source. We demonstrate reliable coupling of an unprecedented rf power—up to 575kW into the mm-wave accelerator structure using a quasi-optical setup. This standing wave accelerating structure consists of a single-cell copper cavity and a Gaussian to TM 01 mode converter. The accelerator structure is powered by 110 GHz, 10-ns long rf pulses. These pulses are chopped from 3 microsecond pulses from a gyrotron oscillator using a laser-driven silicon switch. We show an unprecedented high gradient up to 230MV/m that corresponds to a peak surface electric field of more than 520 MV/m. We have achieved these results after conditioning the cavity with more than 100,000 pulses. We also report preliminary measurements of rf breakdown rates, which are important for understanding rf breakdown physics in the millimeter-wave regime. Furthermore, these results open up many frontiers for applications not only limited to the next generation particle accelerators but also x-ray generation, probing material dynamics, and nonlinear light-matter interactions at mm-wave frequency.

43 PARTICLE ACCELERATORS↗

Axion dark matter detection by superconducting resonant frequency conversion

We propose an approach to search for axion dark matter with a specially designed superconducting radio frequency cavity, targeting axions with masses ma ≲ 10 -6 eV. Our approach exploits axion-induced transitions between nearly degenerate resonant modes of frequency ~ GHz. A scan over axion mass is achieved by varying the frequency splitting between the two modes. Compared to traditional approaches, this allows for parametrically enhanced signal power for axions lighter than a GHz. The projected sensitivity covers unexplored parameter space for QCD axion dark matter for 10 -8 eV ≲ ma ≲ 10 -6 eV and axion-like particle dark matter as light as ma~ 10 -14 eV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel High-Power Microwave Circulator Employing Circularly Polarized Waves

A novel four-port circulator is presented which uses an inline ferromagnetic element to allow for transmission or reflection depending on the sense of the incident circularly polarized wave. This configuration has been shown to reduce the dependency on ferrite anisotropy and support higher power, low rf loss, operation. An analytic analysis of this device is presented here alongside corroborating cold test data of the first prototype. High-power operation was performed at 2.856 GHz, with input power levels up to 8 MW for 3.5 μs in a pressurized nitrogen environment. The results from this research not only demonstrate ability to eliminate the use of greenhouse insulators, such as SF6, but also provide conceptual groundwork for a new class of ultrahigh power (50 MW+) nonreciprocal networks including circulators, isolators, phase shifters, and rf switches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Classical Field Theory Formulation for the Numerical Solution of Time Harmonic Electromagnetic Fields

Finite element representations of Maxwell's equations pose unusual challenges inherent to the variational representation of the “curl-curl” equation for the fields. We present a variational formulation which solves for the four-potential instead, based on classical field theory. Borrowing from quantum electrodynamics, we modify the Lagrangian by adding an implicit gauge-fixing term. This reformulation explicitly accounts for Gauss’ law through the coupling between $\phi$ and $\rho$ , and enables the use of nodal basis functions instead of edge elements for time-harmonic problems. Here, we demonstrate how this formulation, adhering to the deeper underlying symmetries of the four-dimensional covariant field description, provides a highly general, robust numerical framework.

43 PARTICLE ACCELERATORS↗