Enhanced dynamic equivalent identification method of large-scale power systems using multiple events

The increasing complexity of the interconnected power system makes high-fidelity dynamic simulation models computationally more intensive. To improve computation efficiency, model reduction techniques have been investigated to only preserve the dynamics in a limited area of interest (study area), while deriving equivalent representation for the external area. For this purpose, a measurement-based reduction approach using system identification techniques has been previously proposed. Accordingly, external areas are represented by dynamic equivalent loads using transfer function estimation. In this paper, in order to enhance the accuracy of the reduced model in preserving dynamics of the study area, multiple “grid” events of different types and at different locations are considered for identifying the parameters of the equivalent loads. Additionally, case studies are carried out in the NPCC 140-bus system. Comparisons are made between multiple events training and single event training, highlighting the advantages of the proposed method in providing a better representation of the grid dynamics under different operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling the impact of GIC neutral blocking devices on distance protection relay operations for transmission lines

Geomagnetic Induced Current (GIC) blocking devices typically include a capacitor on the neutral grounding path of wye-configured transformers. This type of GIC blocking device was designed as an effective countermeasure to prevent possible damages caused on the power grid by geomagnetic storms, and by the slow-varying component of a high-altitude electromagnetic pulse (HEMP). The insertion of a capacitor in the transformer neutral impedes the establishment of GICs in lines terminated with wye-connected transformer windings. With the presence of a capacitively grounded neutral, however, it becomes important to evaluate that no adverse effects are introduced in the general grid operations. In this context, this study investigates the impact of GIC neutral blocking devices on the functionality of distance protection relays for different values of transformer neutral blocking capacitors, and at different transmission line voltages. This study was conducted with a real-time simulation platform, and the simulations were performed by introducing a phase-to-ground fault at different line locations, and by measuring the apparent impedance at the protection relay location. Finally, the results indicated that, for typical values of capacitance considered for GIC neutral blocking devices, the distance protection relay model operates properly, without requiring a modification of the relay settings.

42 ENGINEERING↗

Measurement-based Power System Dynamic Model Reduction Using ARX Equivalents

The increasing complexity of power system has made it difficult to simulate large-scale power system in detail. Therefore, to improve computational efficiency, model reduction techniques has been applied to reduce the external area and focus on the dynamics of the internal area. This paper proposes a measurement-based model reduction method which reduces the external system by replacing external system with ARX equivalents. The modeled transfer function parameters are obtained using system identification approach. Case studies on the NPCC system and EI system are carried out. Results show that the proposed reduction method can effectively retain the dynamic behavior of the study area while mitigating computation burden.

Jiang, Zhihao↗

Simulation of Fast-Rise Transients in a Large-Power Transformer Winding

A high-altitude electromagnetic pulse (HEMP) may pose a significant threat to the electrical power grid. In this context, the present study considers here the potential impact of the HEMP early-time component (E1) on the winding of a typical transmission power line transformer. A time-domain, fully electromagnetic, three-dimensional, finite-element model was used to simulate the propagation of an E1-induced voltage surge into the transformer winding. The analysis is focused on the first few turns of the winding, the ones that are impacted by the largest electric field resulting from the applied pulse. The model follows the transient dynamics, while the pulse is traveling along the conductor, and the electric field is established across the insulation gaps through capacitive coupling. The simulations also considered the effect of an electrically floating, “shield” winding conductor. This is used as a countermeasure to improve the voltage uniformity across the winding during fast-rise transients. In this case, the propagation of the E1-induced pulse is compared with that from a slower rising, lightning standard waveform. The simulation results show that the presence of the shield conductor can effectively reduce the peak electric field between winding turns, in the presence of either E1 or lightning waveforms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Voltage Modeling and Testing of Transformer, Line Interface Devices, and Bulk System Components Under Electromagnetic Pulse, Geomagnetic Disturbance, and other Abnormal Transients

This project aims at quantitatively analyzing possible knowledge gaps related to the risk of Electromagnetic Pulse (EMP) impact on high-voltage, power transformers (transmission-class), that represent the most critical power grid assets. In relation to the electric infrastructure, some past studies indicate that the grid is overall fairly robust and resilient against most EMP threats. This assessment stems, in part, from estimates of the peak voltage that can be induced on a transmission power line for a nominal EMP fast-transient, compared with the typically very high basic insulation level that is featured by the high-voltage infrastructure. The project provides additional insight toward a more comprehensive risk evaluation of the grid EMP and Geomagnetic Disturbances (GMD) vulnerabilities. This work is aligned with the U.S. Dept. of Energy current research thrust in support of the development of a highly secure and resilient power infrastructure. Project milestones have been devised to address the fundamental technical issues in support of protection of large power transformer against EMP threats. More specifically, this project included parallel research tasks focused on the following topics: analysis of EMP-induced, fast-transient, current and voltages on a variety of power line configurations and EMP impact scenarios, detailed characterization of EMP damage potential due to the voltage surge, from the impact on the power line, to the transformer windings, GMD and EMP slow transients and impact from harmonics generation and reactive power flow on a complex grid layout, and identification of risk mitigation paths, with emphasis on GIC damage prevention for large power transformers, and on impact protection options from a grid stability perspective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EMP Coupling to a Straight Conductor Above Ground: Transmission Line Formulation Based on Electromagnetic Reciprocity

A simple model for coupling of an electromagnetic plane wave incident on a conductor above ground has been developed using reciprocity theory, providing some advantages as compared to the conventional transmission line approach. The model is developed using a semi-infinitely long single conductor above a lossy ground plane and connected by an arbitrary load impedance to a vertical grounding conductor. This configuration corresponds to the worst-case wave coupling, because it leads to a line induced current larger than in the cases of finite and multiconductor lines. A frequency-domain Thévenin equivalent model is developed to relate the incident wave amplitude to the voltage across a generic load, connected at any point on the vertical conductor. The application to the threat analysis of a high-altitude electromagnetic pulse impact on a power transmission line is discussed by considering the time-domain solution (via inverse Fourier transform) for an incident EMP fast-rise transient (E1) waveshape, following the standard IEC specifications. For typical high-voltage power line load impedances, it is shown that voltage magnitudes in the MV range can be induced across the line termination, in the case of a wave with a near-grazing incidence angle and with wave vector aligned along the horizontal conductor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Incidence Angle Impact on EM Wave-Line Coupling

Abstract— For an EM plane wave coupling with a horizontal conductor above ground, the induced current reaches a maximum for small incidence angles. A transmission line analysis shows that this is due to in-phase adding of excited waves along the line.

Tarditi, Alfonso G.↗

HotSpots: Failure Cascades on Heterogeneous Critical Infrastructure Networks

Critical Infrastructure Systems such as transportation, water and power grid systems are vital to our national security, economy, and public safety. Recent events, like the 2012 hurricane Sandy, show how the interdependencies among different CI networks lead to catastrophic failures among the whole system. Hence, analyzing these CI networks, and modeling failure cascades on them becomes a very important problem. However, traditional models either do not take multiple CIs or the dynamics of the system into account, or model it simplistically. In this paper, we study this problem using a heterogeneous network viewpoint. We first construct heterogeneous CI networks with multiple components using national-level datasets. Then we study novel failure maximization problems on these networks, to compute critical nodes in such systems. We then provide HotSpots, a scalable and effective algorithm for these problems, based on careful transformations. Finally, we conduct extensive experiments on real CIS data from multiple US states, and show that our method HotSpots outperforms non-trivial baselines, gives meaningful results and that our approach gives immediate benefits in providing situational-awareness during large-scale failures.

Chen, Liangzhe↗

A Particle-in-Cell Simulation for the Traveling Wave Direct Energy Converter (TWDEC) for Fusion Propulsion

A Particle-in-cell simulation model has been developed to study the physics of the Traveling Wave Direct Energy Converter (TWDEC) applied to the conversion of charged fusion products into electricity. In this model the availability of a beam of collimated fusion products is assumed; the simulation is focused on the conversion of the beam kinetic energy into alternating current (AC) electric power. The model is electrostatic, as the electro-dynamics of the relatively slow ions can be treated in the quasistatic approximation. A two-dimensional, axisymmetric (radial-axial coordinates) geometry is considered. Ion beam particles are injected on one end and travel along the axis through ring-shaped electrodes with externally applied time-varying voltages, thus modulating the beam by forming a sinusoidal pattern in the beam density. Further downstream, the modulated beam passes through another set of ring electrodes, now electrically oating. The modulated beam induces a time alternating potential di erence between adjacent electrodes. Power can be drawn from the electrodes by connecting a resistive load. As energy is dissipated in the load, a corresponding drop in beam energy is measured. The simulation encapsulates the TWDEC process by reproducing the time-dependent transfer of energy and the particle deceleration due to the electric eld phase time variations.

Chap, Andrew↗

Direct Energy Conversion for Low Specific Mass In-Space Power and Propulsion

"Changing the game" in space exploration involves changing the paradigm for the human exploration of the Solar System, e.g, changing the human exploration of Mars from a three-year epic event to an annual expedition. For the purposes of this assessment an "annual expedition" capability is defined as an in-space power & propulsion system which, with launch mass limits as defined in NASA s Mars Architecture 5.0, enables sending a crew to Mars and returning them after a 30-day surface stay within one year, irrespective of planetary alignment. In this work the authors intend to show that obtaining this capability requires the development of an in-space power & propulsion system with an end-to-end specific mass considerably less than 3 kg/kWe. A first order energy balance analysis reveals that the technologies required to create a system with this specific mass include direct energy conversion and nuclear sources that release energy in the form of charged particle beams. This paper lays out this first order approximation and details these conclusions.

Scott, John H.↗

NASA-NIAC 2001 Phase I Research Grant on Aneutronic Fusion Spacecraft Architecture

This study was developed because the recognized need of defining of a new spacecraft architecture suitable for aneutronic fusion and featuring game-changing space travel capabilities. The core of this architecture is the definition of a new kind of fusion-based space propulsion system. This research is not about exploring a new fusion energy concept, it actually assumes the availability of an aneutronic fusion energy reactor. The focus is on providing the best (most efficient) utilization of fusion energy for propulsion purposes. The rationale is that without a proper architecture design even the utilization of a fusion reactor as a prime energy source for spacecraft propulsion is not going to provide the required performances for achieving a substantial change of current space travel capabilities.

aneutronic↗