Search NASA⌕ Search

Engineering topics

Taylor, R

Publications and source records attributed to Taylor, R.

Investigation of background electron emission in the LUX detector

Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of signals from electron emission processes in the low energy region. While this background negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper, we report a systematic investigation of the electron pathologies observed in the LUX dark matter experiment. We characterize different electron populations based on their emission intensities and their correlations with preceding energy depositions in the detector. By studying these electron backgrounds under different experimental conditions, we identified the possible mechanisms that may contribute to the electron emission. We report the observed electron event rate in LUX after background rejection, and discuss how such backgrounds can be further mitigated in ongoing and future xenon-based dark matter experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extending light WIMP searches to single scintillation photons in LUX

© 2020 American Physical Society. We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a twofold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c2 WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-AB-BRC-08: Egs-brachy, a Fast and Versatile Monte Carlo Code for Brachytherapy Applications

Purpose: To introduce egs-brachy, a new, fast, and versatile Monte Carlo code for brachytherapy applications. Methods: egs-brachy is an EGSnrc user-code based on the EGSnrc C++ class library (egs++). Complex phantom, applicator, and source model geometries are built using the egs++ geometry module. egs-brachy uses a tracklength estimator to score collision kerma in voxels. Interaction, spectrum, energy fluence, and phase space scoring are also implemented. Phase space sources and particle recycling may be used to improve simulation efficiency. HDR treatments (e.g. stepping source through dwell positions) can be simulated. Standard brachytherapy seeds, as well as electron and miniature x-ray tube sources are fully modelled. Variance reduction techniques for electron source simulations are implemented (Bremsstrahlung cross section enhancement, uniform Bremsstrahlung splitting, and Russian Roulette). TG-43 parameters of seeds are computed and compared to published values. Example simulations of various treatments are carried out on a single 2.5 GHz Intel Xeon E5-2680 v3 processor core. Results: TG-43 parameters calculated with egs-brachy show excellent agreement with published values. Using a phase space source, 2% average statistical uncertainty in the PTV ((2mm){sup 3} voxels) can be achieved in 10 s for 100 {sup 125}I or {sup 103}Pd seeds in a 36.2 cm{sup 3} prostate PTV, 31 s for 64 {sup 103}Pd seeds in a 64 cm{sup 3} breast PTV, and 56 s for a miniature x-ray tube in a 27 cm{sup 3} breast PTV. Comparable uncertainty is reached in 12 s in a (1 mm){sup 3} water voxel 5 mm away from a COMS 16mm eye plaque with 13 {sup 103}Pd seeds. Conclusion: The accuracy of egs-brachy has been demonstrated through benchmarking calculations. Calculation times are sufficiently fast to allow full MC simulations for routine treatment planning for diverse brachytherapy treatments (LDR, HDR, miniature x-ray tube). egs-brachy will be available as free and open-source software to the medical physics research community. This work is partially funded by the Canada Research Chairs program, the Natural Sciences and Engineering Research Council of Canada, and the Ontario Ministry of Research and Innovation (Ontario Early Researcher Award).

60 APPLIED LIFE SCIENCES↗

SU-E-T-103: Development and Implementation of Web Based Quality Control Software

Purpose: Historically many radiation medicine programs have maintained their Quality Control (QC) test results in paper records or Microsoft Excel worksheets. Both these approaches represent significant logistical challenges, and are not predisposed to data review and approval. It has been our group's aim to develop and implement web based software designed not just to record and store QC data in a centralized database, but to provide scheduling and data review tools to help manage a radiation therapy clinics Equipment Quality control program. Methods: The software was written in the Python programming language using the Django web framework. In order to promote collaboration and validation from other centres the code was made open source and is freely available to the public via an online source code repository. The code was written to provide a common user interface for data entry, formalize the review and approval process, and offer automated data trending and process control analysis of test results. Results: As of February 2014, our installation of QAtrack+ has 180 tests defined in its database and has collected ∼22 000 test results, all of which have been reviewed and approved by a physicist via QATrack+'s review tools. These results include records for quality control of Elekta accelerators, CT simulators, our brachytherapy programme, TomoTherapy and Cyberknife units. Currently at least 5 other centres are known to be running QAtrack+ clinically, forming the start of an international user community. Conclusion: QAtrack+ has proven to be an effective tool for collecting radiation therapy QC data, allowing for rapid review and trending of data for a wide variety of treatment units. As free and open source software, all source code, documentation and a bug tracker are available to the public at https://bitbucket.org/tohccmedphys/qatrackplus/.

07 ISOTOPE AND RADIATION SOURCES↗

Eleven new heaviest isotopes of elements Z = 105 to Z = 117 identified among the products of 249Bk+48Ca reactions

The heaviest isotopes of elements Z = 117 to Z = 105, 294117, 293117, 290115, 289115, 286113, 285113, 282Rg, 281Rg, 278Mt, 274Bh, and 270Db, were identified by means of the Dubna gas-filled recoil separator among the products of the 249Bk + 48Ca reaction. The details of the observed six decay chains, indicating the production and decay of isotopes 293117 and 294117, are presented and discussed. The decay energies and resulting half-lives of these new nuclei show a strong rise of stability with increasing neutron number, validating the concept of the island of enhanced stability for superheavy nuclei.

249Bk+48Ca↗

THE ARECIBO GALAXY ENVIRONMENT SURVEY. III. OBSERVATIONS TOWARD THE GALAXY PAIR NGC 7332/7339 AND THE ISOLATED GALAXY NGC 1156

Two 5 deg{sup 2} regions around the NGC 7332/9 galaxy pair and the isolated galaxy NGC 1156 have been mapped in the 21 cm line of neutral hydrogen (H I) with the Arecibo L-band Feed Array out to a redshift of {approx}0.065 ({approx}20,000 km s{sup -1}) as part of the Arecibo Galaxy Environment Survey. One of the aims of this survey is to investigate the environment of galaxies by identifying dwarf companions and interaction remnants; both of these areas provide the potential for such discoveries. The neutral hydrogen observations were complemented by optical and radio follow-up observations with a number of telescopes. A total of 87 galaxies were found, of which 39 (45%) were previously cataloged and 15 (17%) have prior redshifts. Two dwarf galaxies have been discovered in the NGC 7332 group and a single dwarf galaxy in the vicinity of NGC 1156. A parallel optical search of the area revealed one further possible dwarf galaxy near NGC 7332.

79 ASTRONOMY AND ASTROPHYSICS↗

Composition, morphology and nanostructure of C-S-H in 70% white Portland cement-30% fly ash blends hydrated at 55 {sup o}C

Outer product C-S-H had a mixture of fibrillar and foil-like morphology in a 28-day-old water-activated paste, and foil- or lath-like morphology in an alkali-activated paste. It was not possible to determine the chemical composition of C-S-H using SEM-EDX because of fine-scale intermixing with other phases; TEM-EDX was necessary. The C-S-H formed in the alkali-activated paste had a lower mean Ca/(Al + Si) ratio than that formed with water. The mean length of the aluminosilicate anions in the C-S-H was similar in both systems and increased with age; those in the Op C-S-H were likely to be shorter than those present in the Ip C-S-H with water activation, but longer (and more protonated) with alkali. The potassium in the alkali-activated paste was present either within the C-S-H structure charge balancing the substitution of Al{sup 3+} for Si{sup 4+}, or adsorbed on the C-S-H charge balancing sulfate ions.

36 MATERIALS SCIENCE↗

Structure of Vibrio cholerae ToxT reveals a mechanism for fatty acid regulation of virulence genes

Cholera is an acute intestinal infection caused by the bacterium Vibrio cholerae. In order for V. cholerae to cause disease, it must produce two virulence factors, the toxin-coregulated pilus (TCP) and cholera toxin (CT), whose expression is controlled by a transcriptional cascade culminating with the expression of the AraC-family regulator, ToxT. We have solved the 1.9 {angstrom} resolution crystal structure of ToxT, which reveals folds in the N- and C-terminal domains that share a number of features in common with AraC, MarA, and Rob as well as the unexpected presence of a buried 16-carbon fatty acid, cis-palmitoleate. The finding that cis-palmitoleic acid reduces TCP and CT expression in V. cholerae and prevents ToxT from binding to DNA in vitro provides a direct link between the host environment of V. cholerae and regulation of virulence gene expression.

36 MATERIALS SCIENCE↗

2008 Weatherization and Intergovernmental Program (WIP) Market Report

The Weatherization and Intergovernmental Program (WIP) integrates local needs and interests in order to promote markets for energy efficiency (EE) and renewable energy (RE). Its activities are integrative across disparate technologies and market boundaries. In order to analyze the historical performance and forward-looking potential of this broad program, this report assesses market developments and outlooks at the following aggregated levels: states, cities and communities, Indian tribes, and low-income residential efficiency. The analytical goals of the report are to: identify market drivers for EE and RE, paying attention to subsidies, taxes, targets and mandates, environmental policy, energy security, and economic development; assess efficacy of existing policies; discuss challenges and barriers; evaluate high-impact measures for overcoming challenges and barriers; and forecast future market trends.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

X-ray Absorption Near Edge Structure Study of Lead Sorption on Phosphate-Treated Kaolinite

Presorbed phosphate significantly increases Pb sorption on the phyllosilicate kaolinite in the pH range from 4 to 8. The sorbed Pb-to-P molar ratios over this pH range stray little from the molar ratio found in the mineral pyromorphite, suggesting sorbed phosphate reacts with soluble Pb to form a surface precipitate similar to pyromorphite. X-ray absorption near edge structure (XANES) studies at the Pb L{sub 3}-edge support this interpretation. In particular, the fine structure of first-derivative Pb L{sub 3}-edge XANES spectra of Pb species sorbed to phosphate-treated kaolinite samples covering a pH range extending from 4 to 10 match the fine structure of the spectrum of pyromorphite. Although the product is structurally and compositionally similar to pyromorphite, the ion activity product in the pH range 4-6 was undersaturated with respect to the solubility product of pyromorphite.

36 MATERIALS SCIENCE↗