SU-F-E-07: Web-Based Training for Radiosurgery: Methods and Metrics for Global Reach

Purpose: Webinars have become an evolving tool with greater or lesser success in reaching health care providers (HCPs). This study seeks to assess best practices and metrics for success in webinar deployment for optimal global reach. Methods: Webinars have been developed and launched to reach practicing health care providers in the field of radiation oncology and radiosurgery. One such webinar was launched in early February 2016. “Multiple Brain Metastases & Volumetric Modulated Arc Radiosurgery: Refining the Single-Isocenter Technique to Benefit Surgeons and Patients” presented by Drs. Fiveash and Thomas from UAB was submitted to and accredited by the Institute for Medical Education as qualifying for CME as well as MDCB for educational credit for dosimetrists, in order to encourage participation. MedicalPhysicsWeb was chosen as the platform to inform attendees regarding the webinar. Further IME accredited the activity for 1 AMA PRA Category 1 credit for physicians & medical physicists. The program was qualified by the ABR in meeting the criteria for self-assessment towards fulfilling MOC requirements. Free SAMs credits were underwritten by an educational grant from Varian Medical Systems. Results: The webinar in question attracted 992 pre-registrants from 66 countries. Outside the US and Canada; 11 were from the Americas; 32 were from Europe; 9 from the Middle East and Africa. Australasia and the Indian subcontinent represented the remaining 14 countries. Pre-registrants included 423 Medical Physicists, 225 Medical Dosimetrists, 24 Radiation Therapists, 66 Radiation Oncologists & other. Conclusion: The effectiveness of CME and SAM-CME programs such as this can be gauged by the high rate of respondents who state an intention to change practice habits, a primary goal of continuing medical education and self-assessment. This webinar succeeded in being the most successful webinar on Medical Physics Web as measured by pre-registration, participation and participation to pre-registration ratio. R.A. Schulz is an employee of Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-T-570: Comparison of Synthetic Diamond, Microionization Chamber, and Radiochromic Film for Absolute Dosimetry of VMAT Radiosurgery

Purpose: Patient specific quality assurance of stereotactic radiosurgery (SRS) plans is challenging because of small target sizes and high dose gradients. We compared three detectors for dosimetry of VMAT SRS plans. Methods: The dose at the center of seventeen targets was measured using a synthetic diamond detector (2.2 mm diameter, 1 µm thickness), a 0.007 cm{sup 3} ionization chamber, and radiochromic film. Measurements were made in a PMMA phantom in the clinical geometry – all gantry and table angles were delivered as planned. The diamond and chamber positions were offset by 1 cm from the film plane, so the isocenter was shifted accordingly to place the center of the target at the detector of interest. To ensure accurate detector placement, the phantom was positioned using kV images. To account for the shift-induced difference in geometry and differing prescription doses between plans, the measurements were normalized to the expected dose calculated by the treatment planning system. Results: The target sizes ranged from 2.8 mm to 34.8 mm (median 14.8 mm). The mean measurement-to-plan ratios were 1.054, 1.076, and 1.023 for RCF, diamond, and chamber, respectively. The mean difference between the chamber and film was −3.2% and between diamond and film was 2.2%. For targets larger than 15 mm, the mean difference relative to film was −0.8% and 0.1% for chamber and diamond, respectively, whereas for targets smaller than 15 mm, the difference was −5.3% and 4.2% for chamber and diamond, respectively. The difference was significant (p=0.005) using the two-sample Kolmogorov-Smirnov test. Conclusion: The detectors agree for target sizes larger than 15 mm. Relative to film, for smaller targets the diamond detector over-responds, whereas the ionization chamber under-responds. Further work is needed to characterize detector response in modulated SRS fields.

60 APPLIED LIFE SCIENCES↗

SU-F-T-629: Effect of Multi-Leaf Collimator (MLC) Width On Plan Quality of Single-Isocenter VMAT Intracranial Stereotactic Radiosurgery for Multiple Metastases

Purpose: Single-isocenter VMAT has been shown able to create high quality plans for complex intracranial multiple metastasis SRS cases. Linacs capable of the technique are typically outfitted with an MLC that consists of a combination of 5 mm and 10 mm leaves (standard) or 2.5 mm and 5 mm leaves (high-definition). In this study, we test the hypothesis that thinner collimator leaves are associated with improved plan quality. Methods: Ten multiple metastasis cases were identified and planned for VMAT SRS using a 10 MV flattening filter free beam. Plans were created for a standard (std) and a high-definition (HD) MLC. Published values for leaf transmission factor and dosimetric leaf gap were utilized. All other parameters were invariant. Conformity (plan and individual target), moderate isodose spill (V50%), and low isodose spill (mean brain dose) were selected for analysis. Results: Compared to standard MLC, HD-MLC improved overall plan conformity (median: Paddick CI-HD = 0.83, Paddick CI-std = 0.79; p = 0.004 and median: RTOG CI-HD =1.18, RTOG CI-std =1.24; p = 0.01 ), improved individual lesion conformity (median: Paddick CI-HD,i =0.77, Paddick CI-std,i =0.72; p < 0.001 and median: RTOG CI-HD,i = 1.28, RTOG CI-std,i =1.35; p < 0.001), improved moderate isodose spill (median: V50%-HD = 37.0 cc, V50%-std = 45.7 cc; p = 0.002), and improved low dose spill (median: dmean-HD = 2.90 Gy, dmean-std = 3.19 Gy; p = 0.002). Conclusion: For the single-isocenter VMAT SRS of multiple metastasis plans examined, use of HD-MLC modestly improved conformity, moderate isodose, and low isodose spill compared to standard MLC. However, in all cases we were able to generate clinically acceptable plans with the standard MLC. More work is need to further quantify the difference in cases with higher numbers of small targets and to better understand any potential clinical significance. This research was supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-291: Dosimetric Accuracy of Multitarget Single Isocenter Radiosurgery

Purpose: To evaluate the accuracy of single-isocenter multiple-target VMAT radiosurgery (SIMT-VMAT-SRS) by analysis of pre-treatment verification measurements. Methods: Our QA procedure used a phantom having a coronal plane for EDR2 film and a 0.125 cm3 ionization chamber. Film measurements were obtained for the largest and smallest targets for each plan. An ionization chamber measurement (ICM) was obtained for sufficiently large targets. Films were converted to dose using a patient-specific calibration curve and compared to treatment planning system calculations. Alignment error was estimated using image registration. The gamma index was calculated for 3%/3 and 3%/1 mm criteria. The median dose in the target region and, for plans having an ICM, the average dose in the central 5 mm was calculated. Results: The average equivalent target diameter of the 48 targets was 15 mm (3–43 mm). Twenty of the 24 plans had an ICM for the plan corresponding to the largest target (diameter 11–43 mm) with a mean ratio of chamber reading to expected dose (ED) and the mean ratio of film to ED (averaged over the central 5 mm) was 1.001 (0.025 SD) and 1.000 (0.029 SD), respectively. For all plans, the mean film to ED (from the median dose in the target region) was 0.997 (0.027 SD). The mean registration vector was (0.15,0.29) mm, with an average magnitude of 0.96 mm. Before (after) registration, the average fraction of pixels having gamma < 1 was 99.3% (99.6%) and 89.1% (97.6%) for 3%/3mm and 3%/1mm, respectively. Conclusion: Our results demonstrate dosimetric accuracy of SIMT-VMAT-SRS for targets as small as 3 mm. Film dosimetry provides accurate assessment of the absolute dose delivered to targets too small for an ionization chamber measurement; however, the relatively large registration vector indicates that image-guidance should replace laser-based setup for patient-specific evaluation of geometric accuracy.

60 APPLIED LIFE SCIENCES↗

Visible Mie Scattering in Nonabsorbing Hollow Sphere Powders

Hollow silica nanoparticles (HSNP) with diameters comparable to visible wavelengths and with thin shells (<15 nm) feature an unexpected color effect. Single particle and powder spectroscopy, as well as calculations based on Mie theory were used to investigate this phenomenon. The use of HSNPs increases the transport mean free path of light significantly, which reduces multiple scattering, and thus the Mie resonances become visible to the bare eye.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Structural and thermoelectric properties of BaRCo{sub 4}O{sub 7} (R = Dy, Ho, Er, Tm, Yb, and Lu)

The structure and thermoelectric properties of a series of barium lanthanide cobaltites, BaRCo{sub 4}O{sub 7} (R = Dy, Ho, Er, Tm, Yb, and Lu), which were prepared using the spark plasma synthesis technique, have been investigated. The space group of these compounds was re-determined and confirmed to be P31c instead of the reported P6{sub 3}mc. The lattice parameters a and c range from 6.26279(2) Angst to 6.31181(6) Angst , and from 10.22468(6) Angst to 10.24446(15) Angst for R = Lu to Dy, respectively. The crystal structure of BaRCo{sub 4}O{sub 7} is built up from Kagome sheets of CoO{sub 4} tetrahedra, linked by triangular layers of CoO{sub 4} tetrahedra. The values of figure of merit (ZT) of the BaRCo{sub 4}O{sub 7} samples were determined to be around 0.02 at 800 K. X-ray diffraction patterns of these samples have been determined and submitted to the Powder Diffraction File.

36 MATERIALS SCIENCE↗

Estimating Cardiac Exposure From Breast Cancer Radiotherapy in Clinical Practice

Purpose: To assess the value of maximum heart distance (MHD) in predicting the dose and biologically effective dose (BED) to the heart and the left anterior descending (LAD) coronary artery for left-tangential breast or chest wall irradiation. Methods and Materials: A total of 50 consecutive breast cancer patients given adjuvant left-tangential irradiation at a large U.K. radiotherapy center during 2006 were selected. For each patient, the following were derived using three-dimensional computed tomography (CT) planning: (1) mean dose and BED to the heart, (2) mean dose and BED to the LAD coronary artery, (3) MHD, (4) position of the CT slice showing the maximum area of the irradiated heart relative to the mid-plane slice, and (5) sternal and contralateral breast thickness (measures of body fat). Results: A strong linear correlation was found between the MHD and the mean heart dose. For every 1-cm increase in MHD, the mean heart dose increased by 2.9% on average (95% confidence interval 2.5-3.3). A strong linear-quadratic relationship was seen between the MHD and the mean heart BED. The mean LAD coronary artery dose and BED were also correlated with the MHD but the associations were weaker. These relationships were not affected by body fat. The mid-plane CT slice did not give a reliable assessment of cardiac irradiation. Conclusion: The MHD is a reliable predictor of the mean heart dose and BED and gives an approximate estimate of the mean LAD coronary artery dose and BED. Doses predicted by the MHD could help assess the risk of radiation-induced cardiac toxicity where individual CT-based cardiac dosimetry is not possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Spring-Like Behavior of Chiral Block Copolymer with Helical Nanostructure Driven by Crystallization

The crystallization of helical nanostructure resulting from the self-assembly of a chiral diblock copolymer, poly(styrene)-b-poly(L-lactide) (PS-PLLA), is studied. Various crystalline PS-PLLA nanostructures are obtained by controlling the crystallization temperature of PLLA (T{sub c,PLLA}), at which crystalline helices and crystalline cylinders occur while T{sub c,PLLA} < T{sub g,PS} (the glass transition temperature of PS) and T{sub c,PLLA} T{sub g,PS}, respectively. As evidenced by selected-area electron diffraction and two-dimensional X-ray diffraction results, the PLLA crystallites under confinement reveal a unique anisotropic character regardless of the crystallization temperature. On the basis of observed uniaxial scattering results the PLLA crystallites grown within the microdomains are identified as crystals with preferential growth directions either along the [100] or along the [110]-axes of the PLLA crystalline unit cell, at which the molecular chains and the growth direction are normal and parallel to the central axes of helices, respectively. The formation of this exclusive crystalline growth is attributed to the spatial confinement effect for crystallization. While T{sub c,PLLA} < T{sub g,PS}, owing to the directed crystallization by helical confinement, the preferential crystalline growth leads to the crystallization following a helical track with growth direction parallel to the central axes of helices through a twisting mechanism. Consequently, winding crystals with specific crystallographic orientation within the helical microdomains can be found. By contrast, while T{sub c,PLLA} {ge} T{sub g,PS}, the preferential growth may modulate the curvature of microdomains by shifting the molecular chains to access the fast path for crystalline growth due to the increase in chain mobility. As a result, a spring-like behavior of the helical nanostructure can be driven by crystallization so as to dictate the transformation of helices, resulting in crystalline cylinders that might be applicable to the design of switchable large-strain actuators.

36 MATERIALS SCIENCE↗

Strongly segregated cubic microdomain morphology consistent with the double gyroid phase in high molecular weight diblock copolymers of polystyrene and poly(dimethylsiloxane)

We report the observation of a cubic phase consistent with the double gyroid structure in strongly segregated diblock copolymers of PS-b-PDMS over a volume fraction ({phi}{sub PDMS}) range of {approx}0.39 to 0.45. The samples have respective molecular weights of 127 kg/mol and 73 kg/mol and degree of segregation N{sub {chi}} equal to 187 and 106, respectively, at annealing temperature of 130 C. It is important to highlight that two out of the total four samples investigated, exhibited hexagonally close packed cylindrical domains of PDMS and alternating lamellae at {phi}{sub PDMS} = 0.39 and 0.45, respectively, indicating the possible narrow range of the DG morphology for the specific diblock copolymers.

36 MATERIALS SCIENCE↗

Block Copolymers with a Twist

Chiral block copolymers (BCPs*) comprising chiral entities were designed to fabricate helical architectures (i.e., twisted morphologies) from self-assembly. A new helical phase (H*) with P622 symmetry was discovered in the self-assembly of poly(styrene)-b-poly(l-lactide) (PS-PLLA) BCPs*. Hexagonally packed, interdigitated PLLA helical microdomains in a PS matrix were directly visualized by electron tomography. The phase diagram of the PS-PLLA BCPs* was also established. Phase transitions from the H* phase to the stable cylinder and gyroid phases were found after long-time annealing, suggesting that the H* is a long-lived metastable phase. In contrast to racemic poly(styrene)-b-poly(d,l-lactide) BCPs, chiral interaction significantly enhances the incompatibility between achiral PS and chiral PLLA blocks in the PS-PLLA BCPs* and can be estimated through the determination of the interaction parameter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of Increased Crystallinity in Deformation-Induced Structure of Segmented Thermoplastic Polyurethane Elastomers with PEO and PEO#PPO#PEO Soft Segments and HDI Hard Segments

The phase-segregated nature of polyurethanes allows meaningful connections to be made between morphological and physical properties. We have taken advantage of this behavior by synthesizing a series of polyurethanes with varying extents of crystallinity and studying their morphologies in both the unstrained and deformed states, going from a completely amorphous soft segment to one with similar chemistry that displays a high extent of soft domain crystallization, thus enhancing phase segregation. The presence of dispersed semicrystalline regions within the continuous soft domain has been shown to provide a reinforcing effect when compared to that of a non-crystalline soft segment polyurethane. Incorporating a semicrystalline soft segment (PEO, 1000 g/mol) has been shown to improve overall sample toughness; however, if higher molecular weight PEO soft segments are employed (4600 g/mol), extensibility and, consequently, toughness are adversely affected due to an increased continuous domain modulus. In-situ deformation experiments demonstrate two very different deformation responses. In the copolymer-containing polyurethane (PEO-PPO-PEO, 1900 g/mol), the hard domains retain a tilted configuration up to strains of 450%, with only a small fraction of the hard segments undergoing reshuffling. The PEO1000-containing polyurethane, on the other hand, begins to demonstrate meridional scattering at strains of 200%, with it being the dominant peak by a strain of 300%. These two deformation behaviors are indicative of the two primary responses to deformation, which are shear and tensile, respectively. Frequently, a tensile mechanism points to decreased polyurethane mechanical properties, though this phenomenon is not seen in the series of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystal Orientation Change and Its Origin in One-Dimensional Nanoconfinement Constructed by Polystyrene-block-poly(ethylene oxide) Single Crystal Mats

Utilizing crystalline-amorphous block copolymers, such as in the case of polystyrene-block-poly(ethylene oxide) (PS-b-PEO), under a large amplitude shear process provides an opportunity for investigating crystal growth and orientation within nanoconfinements at different supercoolings. However, the internal stress generated during the shearing process and the structural defects embedded in the phase-separated morphology inevitably play roles in affecting the confinement effect on the crystallization of the crystalline blocks. In this study, we designed a one-dimensional (1D), defect-free confinement constructed by PS-b-PEO single crystal mats collected in dilute solution. Each single crystal possessed a square-shaped, 'sandwiched' lamellar structure, and it consisted of a PEO single crystal layer between two PS nanolayers formed by the tethered PS blocks on the PEO single crystal top and bottom fold surfaces. Furthermore, in these single crystal mats the glass transition temperature of the PS blocks is higher than the melting temperature of the PEO single crystals. We melted the PEO crystals between the two vitrified PS nanolayers, and the PEO blocks were recrystallized isothermally by quenching the mats to preset recrystallization temperatures (T{sub rx}). The results showed that this change of the PEO crystal orientation takes place within a few degrees Celsius. Microscopically, the crystal orientation might be determined from the status of critical nuclei formation due to the size and shape of this 1D confinement. This likely included a competition between the high tethering density (the junctions) of the PEO blocks at the PS interfaces leading to the homeotropic orientation with an anisotropic conformational orientation of the PEO blocks in the melt and the anisotropic density fluctuations within the 1D confined layer which could lead to an anisotropic ability for the PEO blocks to overcome the nucleation barrier to form the homogeneous orientation. The resolution of these two factors might explain the origin of the crystal orientation change in 1D confined crystallization.

36 MATERIALS SCIENCE↗