Extreme Tele-Echocardiography: Methodology for Remote Guidance of In-Flight Echocardiography Aboard the International Space Station

Methods: In the year before launch of an ISS mission, potential astronaut echocardiographic operators participate in 5 sessions to train for echo acquisitions that occur roughly monthly during the mission, including one exercise echocardiogram. The focus of training is familiarity with the study protocol and remote guidance procedures. On-orbit, real-time guidance of in-flight acquisitions is provided by a sonographer in the Telescience Center of Mission Control. Physician investigators with remote access are able to relay comments on image quality to the sonographer. Live video feed is relayed from the ISS to the ground via the Tracking and Data Relay Satellite System with a 2- second transmission delay. The expert sonographer uses these images, along with twoway audio, to provide instructions and feedback. Images are stored in non-compressed DICOM format for asynchronous relay to the ground for subsequent off-line analysis. Results: Since June, 2009, a total of 27 resting echocardiograms and 5 exercise studies have been performed during flight. Average acquisition time has been 45 minutes, reflecting 26,000 km of ISS travel per study. Image quality has been adequate in all studies, and remote guidance has proven imperative for fine-tuning imaging and prioritizing views when communication outages limit the study duration. Typical resting studies have included 27 video loops and 30 still-frame images requiring 750 MB of storage. Conclusions: Despite limited crew training, remote guidance allows research-quality echocardiography to be performed by non-experts aboard the ISS. Analysis is underway and additional subjects are being recruited to define the impact of microgravity on cardiac structure and systolic and diastolic function.

Martin, David S.↗

Extreme Tele-Echocardiography: Methodology for Remote Guidance of In-flight Echocardiography Aboard the International Space Station

Echocardiography is ideally suited for cardiovascular imaging in remote environments, but the expertise to perform it is often lacking. In 2001, an ATL HDI5000 was delivered to the International Space Station (ISS). The instrument is currently being used in a study to investigate the impact of long-term microgravity on cardiovascular function. The purpose of this report is to describe the methodology for remote guidance of echocardiography in space. Methods: In the year before launch of an ISS mission, potential astronaut echocardiographic operators participate in 5 sessions to train for echo acquisitions that occur roughly monthly during the mission, including one exercise echocardiogram. The focus of training is familiarity with the study protocol and remote guidance procedures. On-orbit, real-time guidance of in-flight acquisitions is provided by a sonographer in the Telescience Center of Mission Control. Physician investigators with remote access are able to relay comments on image optimization to the sonographer. Live video feed is relayed from the ISS to the ground via the Tracking and Data Relay Satellite System with a 2 second transmission delay. The expert sonographer uses these images along with two-way audio to provide instructions and feedback. Images are stored in non-compressed DICOM format for asynchronous relay to the ground for subsequent off-line analysis. Results: Since June, 2009, a total of 19 resting echocardiograms and 4 exercise studies have been performed in-flight. Average acquisition time has been 45 minutes, reflecting 26,000 km of ISS travel per study. Image quality has been adequate in all studies, but remote guidance has proven imperative for fine-tuning imaging and prioritizing views when communication outages limit the study duration. Typical resting studies have included 12 video loops and 21 still-frame images requiring 750 MB of storage. Conclusions: Despite limited crew training, remote guidance allows research-quality echocardiography to be performed by non-experts aboard the ISS. Analysis is underway and additional subjects are being recruited to define the impact of microgravity on cardiac structure and systolic and diastolic function.

Martin, David↗

Improvement in diastolic intraventricular pressure gradients in patients with HOCM after ethanol septal reduction

We sought to validate measurement of intraventricular pressure gradients (IVPG) and analyze their change in patients with hypertrophic obstructive cardiomyopathy (HOCM) after ethanol septal reduction (ESR). Quantitative analysis of color M-mode Doppler (CMM) images may be used to estimate diastolic IVPG noninvasively. Noninvasive IVPG measurement was validated in 10 patients undergoing surgical myectomy. Echocardiograms were then analyzed in 19 patients at baseline and after ESR. Pulsed Doppler data through the mitral valve and pulmonary venous flow were obtained. CMM was used to obtain the flow propagation velocity (Vp) and to calculate IVPG off-line. Left atrial pressure was estimated with the use of previously validated Doppler equations. Data were compared before and after ESR. CMM-derived IVPG correlated well with invasive measurements obtained before and after surgical myectomy [r = 0.8, P < 0.01, Delta(CMM - invasive IVPG) = 0.09 +/- 0.45 mmHg]. ESR resulted in a decrease of resting LVOT systolic gradient from 62 +/- 10 to 29 +/- 5 mmHg (P < 0.001). There was a significant increase in the Vp and IVPG (from 48 +/- 5to 74 +/- 7 cm/s and from 1.5 +/- 0.2 to 2.6 +/- 0.3 mmHg, respectively, P < 0.001 for both). Estimated left atrial pressure decreased from 16.2 +/- 1.1 to 11.5 +/- 0.9 mmHg (P < 0.001). The increase in IVPG correlated with the reduction in the LVOT gradient (r = 0.6, P < 0.01). Reduction of LVOT obstruction after ESR is associated with an improvement in diastolic suction force. Noninvasive measurements of IVPG may be used as an indicator of diastolic function improvement in HOCM.

NASA Program Biomedical Research and Countermeasur↗

Importance of mitral valve repair associated with left ventricular reconstruction for patients with ischemic cardiomyopathy: a real-time three-dimensional echocardiographic study

BACKGROUND: Left ventricular (LV) reconstruction surgery leads to early improvement in LV function in ischemic cardiomyopathy (ICM) patients. This study was designed to evaluate the impact of mitral valve (MV) repair associated with LV reconstruction on LV function 1-year after surgery in ICM patients assessed by real-time 3-dimensional echocardiography (3DE). METHODS AND RESULTS: Sixty ICM patients who underwent the combination surgery (LV reconstruction in 60, MV repair in 30, and revascularization in 52 patients) were studied. Real-time 3DE was performed and LV volumes were obtained at baseline, discharge, 6-month and >or=12-month follow-up. Reduction in end-diastolic volumes (EDV) by 29% and in end-systolic volumes by 38% were demonstrated immediately after surgery and remained at subsequent follow-up (P<0.0001). The LV ejection fraction significantly increased by about 10% at discharge and was maintained >or=12-month (P<0.0001). Although the LV volumes were significantly larger in patients with MV repair before surgery (EDV, 235+/-87 mL versus 193+/-67 mL, P<0.05), they were similar to LV volumes of the patients without MV repair at subsequent follow-ups. However, the EDV increased from 139+/-24 mL to 227+/-79 mL (P<0.01) in 7 patients with recurrent mitral regurgitation (MR). Improvement in New York Heart Association functional class occurred in 81% patients during late follow-up. CONCLUSIONS: Real-time 3DE demonstrates that LV reconstruction provides significant reduction in LV volumes and improvement in LV function which is sustained throughout the 1-year follow-up with 84% cardiac event free survival. If successful, MV repair may prevent LV redilation, while recurrent MR is associated with increased LV volumes.

Clinical Trial↗

Effect of stromal-cell-derived factor 1 on stem-cell homing and tissue regeneration in ischaemic cardiomyopathy

BACKGROUND: Myocardial regeneration via stem-cell mobilisation at the time of myocardial infarction is known to occur, although the mechanism for stem-cell homing to infarcted tissue subsequently and whether this approach can be used for treatment of ischaemic cardiomyopathy are unknown. We investigated these issues in a Lewis rat model (ligation of the left anterior descending artery) of ischaemic cardiomyopathy. METHODS: We studied the effects of stem-cell mobilisation by use of granulocyte colony-stimulating factor (filgrastim) with or without transplantation of syngeneic cells. Shortening fraction and myocardial strain by tissue doppler imaging were quantified by echocardiography. FINDINGS: Stem-cell mobilisation with filgrastim alone did not lead to engraftment of bone-marrow-derived cells. Stromal-cell-derived factor 1 (SDF-1), required for stem-cell homing to bone marrow, was upregulated immediately after myocardial infarction and downregulated within 7 days. 8 weeks after myocardial infarction, transplantation into the peri-infarct zone of syngeneic cardiac fibroblasts stably transfected to express SDF-1 induced homing of CD117-positive stem cells to injured myocardium after filgrastim administration (control vs SDF-1-expressing cardiac fibroblasts mean 7.2 [SD 3.4] vs 33.2 [6.0] cells/mm2, n=4 per group, p<0.02) resulting in greater left-ventricular mass (1.24 [0.29] vs 1.57 [0.27] g) and better cardiac function (shortening fraction 9.2 [4.9] vs 17.2 [4.2]%, n=8 per group, p<0.05). INTERPRETATION: These findings show that SDF-1 is sufficient to induce therapeutic stem-cell homing to injured myocardium and suggest a strategy for directed stem-cell engraftment into injured tissues. Our findings also indicate that therapeutic strategies focused on stem-cell mobilisation for regeneration of myocardial tissue must be initiated within days of myocardial infarction unless signalling for stem-cell homing is re-established.

NASA Discipline Cardiopulmonary↗

An evaluation of the use of new Doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model

BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P <.0001). In contrast to the mitral inflow velocities, mitral annulus early diastolic velocity decreased steadily (12.3-7.3 cm/s) resulting in a dramatic decrease in mitral annulus early/late (1.22-0.57) diastolic velocity with no tendency toward pseudonormalization. The color M-mode Doppler flow propagation velocity also showed significant steady decrease (57-24 cm/s) throughout the pacing period. Multiple regression analysis chose mitral annulus systolic velocity (r = 0.895, P <.0001) and propagation velocity (r = 0.782, P <.0001) for the most important factor predicting LV systolic and diastolic function, respectively. CONCLUSIONS: Doppler tissue echocardiography and color M-mode Doppler flow could evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

Evaluation Studies↗

Comparison of left ventricular diastolic function in obstructive hypertrophic cardiomyopathy in patients undergoing percutaneous septal alcohol ablation versus surgical myotomy/myectomy

Both percutaneous transcoronary alcohol septal reduction (ASR) and surgical myectomy are effective treatments to relieve left ventricular (LV) outflow tract obstruction in obstructive hypertrophic cardiomyopathy (HC). LV diastolic function was assessed by echocardiography in 57 patients with obstructive HC at baseline and 5 +/- 4 months after ASR (n = 37) or surgical myectomy (n = 20). LV outflow tract pressure gradient decreased from 65 +/- 40 to 23 +/- 21 mm Hg (p <0.01) after treatment. The ratio of the early-to-late peak diastolic LV inflow velocities, and the ratio of the early peak diastolic LV inflow velocity to the lateral mitral annulus early diastolic velocity determined by tissue Doppler imaging significantly decreased after the procedures (1.6 +/- 1.7 vs 1.0 +/- 0.7 and 15 +/- 8 vs 11 +/- 5, respectively), whereas LV inflow propagation velocity significantly increased (60 +/- 24 vs 71 +/- 36 cm/s). Left atrial size decreased from 29 +/- 7 to 25 +/- 6 cm(2) (p <0.05). Patients had a significant improvement in New York Heart Association functional class and in exercise performance. When comparing ASR with myectomy, no difference was found in the degree of change in any parameter of diastolic function. Thus, diastolic function indexes obtained by echocardiography changed after septal reduction interventions in patients with obstructive HC; this change was similar to that after surgical myectomy and ASR.

Non-NASA Center↗

Geometric differences of the mitral apparatus between ischemic and dilated cardiomyopathy with significant mitral regurgitation: real-time three-dimensional echocardiography study

BACKGROUND: This study was conducted to elucidate the geometric differences of the mitral apparatus in patients with significant mitral regurgitation caused by ischemic cardiomyopathy (ICM-MR) and by idiopathic dilated cardiomyopathy (DCM-MR) by use of real-time 3D echocardiography (RT3DE). METHODS AND RESULTS: Twenty-six patients with ICM-MR caused by posterior infarction, 18 patients with DCM-MR, and 8 control subjects were studied. With the 3D software, commissure-commissure plane and 3 perpendicular anteroposterior (AP) planes were generated for imaging the medial, central, and lateral sides of the mitral valve (MV) during mid systole. In 3 AP planes, the angles between the annular plane and each leaflet (anterior, Aalpha; posterior, Palpha) were measured. In ICM-MR, Aalpha measured in the medial and central planes was significantly larger than that in the lateral plane (39+/-5 degrees, 34+/-6 degrees, and 27+/-5 degrees, respectively; P<0.01), whereas Palpha showed no significant difference in any of the 3 AP planes (61+/-7 degrees, 57+/-7 degrees, and 56+/-7 degrees, P>0.05). In DCM-MR, both Aalpha (38+/-8 degrees, 37+/-9 degrees, and 36+/-7 degrees, P>0.05) and Palpha (59+/-6 degrees, 58+/-5 degrees, and 57+/-6 degrees, P>0.05) revealed no significant differences in the 3 planes. CONCLUSIONS: The pattern of MV deformation from the medial to the lateral side was asymmetrical in ICM-MR, whereas it was symmetrical in DCM-MR. RT3DE is a helpful tool for differentiating the geometry of the mitral apparatus between these 2 different types of functional mitral regurgitation.

Evaluation Studies↗

Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience

BACKGROUND: Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS: In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS: In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P <.001, delta = -0.91 +/- 2.65 mL). In patients, real-time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P <.001, delta = -4.8 +/- 7.6 mL). CONCLUSIONS: real-time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.

Validation Studies↗

Left ventricular outflow tract mean systolic acceleration as a surrogate for the slope of the left ventricular end-systolic pressure-volume relationship

OBJECTIVE: The goal of this study was to analyze left ventricular outflow tract systolic acceleration (LVOT(Acc)) during alterations in left ventricular (LV) contractility and LV filling. BACKGROUND: Most indexes described to quantify LV systolic function, such as LV ejection fraction and cardiac output, are dependent on loading conditions. METHODS: In 18 sheep (4 normal, 6 with aortic regurgitation, and 8 with old myocardial infarction), blood flow velocities through the LVOT were recorded using conventional pulsed Doppler. The LVOT(Acc) was calculated as the aortic peak velocity divided by the time to peak flow; LVOT(Acc) was compared with LV maximal elastance (E(m)) acquired by conductance catheter under different loading conditions, including volume and pressure overload during an acute coronary occlusion (n = 10). In addition, a clinically validated lumped-parameter numerical model of the cardiovascular system was used to support our findings. RESULTS: Left ventricular E(m) and LVOT(Acc) decreased during ischemia (1.67 +/- 0.67 mm Hg.ml(-1) before vs. 0.93 +/- 0.41 mm Hg.ml(-1) during acute coronary occlusion [p < 0.05] and 7.9 +/- 3.1 m.s(-2) before vs. 4.4 +/- 1.0 m.s(-2) during coronary occlusion [p < 0.05], respectively). Left ventricular outflow tract systolic acceleration showed a strong linear correlation with LV E(m) (y = 3.84x + 1.87, r = 0.85, p < 0.001). Similar findings were obtained with the numerical modeling, which demonstrated a strong correlation between predicted and actual LV E(m) (predicted = 0.98 [actual] -0.01, r = 0.86). By analysis of variance, there was no statistically significant difference in LVOT(Acc) under different loading conditions. CONCLUSIONS: For a variety of hemodynamic conditions, LVOT(Acc) was linearly related to the LV contractility index LV E(m) and was independent of loading conditions. These findings were consistent with numerical modeling. Thus, this Doppler index may serve as a good noninvasive index of LV contractility.

Non-NASA Center↗

Pulmonary venous flow determinants of left atrial pressure under different loading conditions in a chronic animal model with mitral regurgitation

BACKGROUND: The aim of our study was to quantitatively compare the changes and correlations between pulmonary venous flow variables and mean left atrial pressure (mLAP) under different loading conditions in animals with chronic mitral regurgitation (MR) and without MR. METHODS: A total of 85 hemodynamic conditions were studied in 22 sheep, 12 without MR as control (NO-MR group) and 10 with MR (MR group). We obtained pulmonary venous flow systolic velocity (Sv) and diastolic velocity (Dv), Sv and Dv time integrals, their ratios (Sv/Dv and Sv/Dv time integral), mLAP, left ventricular end-diastolic pressure, and MR stroke volume. We also measured left atrial a, x, v, and y pressures and calculated the difference between v and y pressures. RESULTS: Average MR stroke volume was 10.6 +/- 4.3 mL/beat. There were good correlations between Sv (r = -0.64 and r = -0.59, P <.01), Sv/Dv (r = -0.62 and r = -0.74, P <.01), and mLAP in the MR and NO-MR groups, respectively. Correlations were also observed between Dv time integral (r = 0.61 and r = 0.57, P <.01) and left ventricular end-diastolic pressure in the MR and NO-MR groups. In velocity variables, Sv (r = -0.79, P <.001) was the best predictor of mLAP in both groups. The sensitivity and specificity of Sv = 0 in predicting mLAP 15 mm Hg or greater were 86% and 85%, respectively. CONCLUSION: Pulmonary venous flow variables correlated well with mLAP under altered loading conditions in the MR and NO-MR groups. They may be applied clinically as substitutes for invasively acquired indexes of mLAP to assess left atrial and left ventricular functional status.

Pulmonary Veins/physiopathology↗

Quantitative analysis of aortic regurgitation: real-time 3-dimensional and 2-dimensional color Doppler echocardiographic method--a clinical and a chronic animal study

BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.

Validation Studies↗

Contrast and harmonic imaging improves accuracy and efficiency of novice readers for dobutamine stress echocardiography

BACKGROUND: Newer contrast agents as well as tissue harmonic imaging enhance left ventricular (LV) endocardial border delineation, and therefore, improve LV wall-motion analysis. Interpretation of dobutamine stress echocardiography is observer-dependent and requires experience. This study was performed to evaluate whether these new imaging modalities would improve endocardial visualization and enhance accuracy and efficiency of the inexperienced reader interpreting dobutamine stress echocardiography. METHODS AND RESULTS: Twenty-nine consecutive patients with known or suspected coronary artery disease underwent dobutamine stress echocardiography. Both fundamental (2.5 MHZ) and harmonic (1.7 and 3.5 MHZ) mode images were obtained in four standard views at rest and at peak stress during a standard dobutamine infusion stress protocol. Following the noncontrast images, Optison was administered intravenously in bolus (0.5-3.0 ml), and fundamental and harmonic images were obtained. The dobutamine echocardiography studies were reviewed by one experienced and one inexperienced echocardiographer. LV segments were graded for image quality and function. Time for interpretation also was recorded. Contrast with harmonic imaging improved the diagnostic concordance of the novice reader to the expert reader by 7.1%, 7.5%, and 12.6% (P < 0.001) as compared with harmonic imaging, fundamental imaging, and fundamental imaging with contrast, respectively. For the novice reader, reading time was reduced by 47%, 55%, and 58% (P < 0.005) as compared with the time needed for fundamental, fundamental contrast, and harmonic modes, respectively. With harmonic imaging, the image quality score was 4.6% higher (P < 0.001) than for fundamental imaging. Image quality scores were not significantly different for noncontrast and contrast images. CONCLUSION: Harmonic imaging with contrast significantly improves the accuracy and efficiency of the novice dobutamine stress echocardiography reader. The use of harmonic imaging reduces the frequency of nondiagnostic wall segments.

Non-NASA Center↗

Digital echocardiography 2002: now is the time

The ability to acquire echocardiographic images digitally, store and transfer these data using the DICOM standard, and routinely analyze examinations exists today and allows the implementation of a digital echocardiography laboratory. The purpose of this review article is to outline the critical components of a digital echocardiography laboratory, discuss general strategies for implementation, and put forth some of the pitfalls that we have encountered in our own implementation. The major components of the digital laboratory include (1) digital echocardiography machines with network output, (2) a switched high-speed network, (3) a high throughput server with abundant local storage, (4) a reliable low-cost archive, (5) software to manage information, and (6) support mechanisms for software and hardware. Implementation strategies can vary from a complete vendor solution providing all components (hardware, software, support), to a strategy similar to our own where standard computer and networking hardware are used with specialized software for management of image and measurement information.

Review↗

Pulmonary venous flows reflect changes in left atrial hemodynamics during mitral balloon valvotomy

Patients with mitral stenosis have usually blunted pulmonary venous (PV) flow, because of decreased mitral valve area and diastolic dysfunction. The authors compared changes in Doppler PV velocities by using transesophageal echocardiography (TEE) against hemodynamics parameters before and after mitral balloon valvotomy to observe relevance of PV velocities and endsystolic left atrial (LA) pressure-volume relationship. In 25 patients (aged 35 +/- 17 years) with mitral stenosis in sinus rhythm, changes in LA pressure and volumes were compared with PV velocities before and after valvotomy. Mitral valve area, mitral gradients, and deceleration time were obtained. Mitral valve area and mitral gradients changed from 1 +/- 0.2 cm2 and 14.6 +/- 5.4 mmHg to 1.9 +/- 0.3 cm2 and 6.3 +/- 1.7 mmHg, respectively (p<0.001). AR peak reverse flow velocity and AR duration decreased from 29 +/- 13 cm/s and 110 =/- 30 msec to 19 +/- 6 cm/s and 80 +/- 29 msec respectively (p<0.001). Transmitral Doppler E wave deceleration time decreased from 327 +/- 85 to 209 +/- 61 s and cardiac output increased from 4.2 +/- 1.0 to 5.2 +/- 1.1 L/minute (p<0.001). The changes in LA pressure were correlated with changes in S/D (r=0.57, p<0.05). The changes in endsystolic LA pressure-volume relationship were also correlated with changes in S/D (r=0.52, p<0.05). Endsystolic LA pressure-volume relationship decreased after mitral balloon valvotomy, as a result of a large decrease in pressure. PV systolic/diastolic (S/D) waves ratio reflects endsystolic LA pressure-volume relationship and may be used as another indicator of successful valvotomy.

Non-NASA Center↗

Survival after aortic valve replacement for severe aortic stenosis with low transvalvular gradients and severe left ventricular dysfunction

OBJECTIVE: We sought to assess whether aortic valve replacement (AVR) among patients with severe aortic stenosis (AS), severe left ventricular (LV) dysfunction and a low transvalvular gradient (TVG) is associated with improved survival. BACKGROUND: The optimal management of patients with severe AS with severe LV dysfunction and a low TVG remains controversial. METHODS: Between 1990 and 1998, we evaluated 68 patients who underwent AVR at our institution (AVR group) and 89 patients who did not undergo AVR (control group), with an aortic valve area < or = 0.75 cm(2), LV ejection fraction < or = 35% and mean gradient < or = 30 mm Hg. Using propensity analysis, survival was compared between a cohort of 39 patients in the AVR group and 56 patients in the control group. RESULTS: Despite well-matched baseline characteristics among propensity-matched patients, the one- and four-year survival rates were markedly improved in patients in the AVR group (82% and 78%), as compared with patients in the control group (41% and 15%; p < 0.0001). By multivariable analysis, the main predictor of improved survival was AVR (adjusted risk ratio 0.19, 95% confidence interval 0.09 to 0.39; p < 0.0001). The only other predictors of mortality were age and the serum creatinine level. CONCLUSIONS: Among select patients with severe AS, severe LV dysfunction and a low TVG, AVR was associated with significantly improved survival.

NASA Discipline Cardiopulmonary↗

Impact of left ventricular outflow tract area on systolic outflow velocity in hypertrophic cardiomyopathy: a real-time three-dimensional echocardiographic study

OBJECTIVES: The aim of this study was to use real-time three-dimensional echocardiography (3DE) to investigate the quantitative relation between minimal left ventricular (LV) outflow tract area (A(LVOT)) and maximal LV outflow tract (LVOT) velocity in patients with hypertrophic obstructive cardiomyopathy (HCM). BACKGROUND: In patients with HCM, LVOT velocity should change inversely with minimal A(LVOT) unless LVOT obstruction reduces the pumping capacity of the ventricle. METHODS: A total of 25 patients with HCM with systolic anterior motion (SAM) of the mitral valve leaflets underwent real-time 3DE. The smallest A(LVOT) during systole was measured using anatomically oriented two-dimensional "C-planes" within the pyramidal 3DE volume. Maximal velocity across LVOT was evaluated by two-dimensional Doppler echocardiography (2DE). For comparison with 3DE A(LVOT), the SAM-septal distance was determined by 2DE. RESULTS: Real-time 3DE provided unique information about the dynamic SAM-septal relation during systole, with A(LVOT) ranging from 0.6 to 5.2 cm(2) (mean: 2.2 +/- 1.4 cm(2)). Maximal velocity (v) correlated inversely with A(LVOT) (v = 496 A(LVOT)(-0.80), r = -0.95, p < 0.001), but the exponent (-0.80) was significantly different from -1.0 (95% confidence interval: -0.67 to -0.92), indicating a significant impact of small A(LVOT) on the peak LVOT flow rate. By comparison, the best correlation between velocity and 2DE SAM-septal distance was significantly (p < 0.01) poorer at -0.83, indicating the superiority of 3DE for assessing A(LVOT). CONCLUSIONS: Three-dimensional echocardiography-measured A(LVOT) provides an assessment of HCM geometry that is superior to 2DE methods. These data indicate that the peak LVOT flow rate appears to be significantly decreased by reduced A(LVOT). Real-time 3DE is a potentially valuable clinical tool for assessing patients with HCM.

NASA Discipline Cardiopulmonary↗

Doppler-derived myocardial systolic strain rate is a strong index of left ventricular contractility

BACKGROUND: Myocardial fiber strain is directly related to left ventricular (LV) contractility. Strain rate can be estimated as the spatial derivative of velocities (dV/ds) obtained by tissue Doppler echocardiography (TDE). The purposes of the study were (1) to determine whether TDE-derived strain rate may be used as a noninvasive, quantitative index of contractility and (2) to compare the relative accuracy of systolic strain rate against TDE velocities alone. METHODS AND RESULTS: TDE color M-mode images of the interventricular septum were recorded from the apical 4-chamber view in 7 closed-chest anesthetized mongrel dogs during 5 different inotropic stages. Simultaneous LV volume and pressure were obtained with a combined conductance-high-fidelity pressure catheter. Peak elastance (Emax) was determined as the slope of end-systolic pressure-volume relationships during caval occlusion and was used as the gold standard of LV contractility. Peak systolic TDE myocardial velocities (Sm) and peak (epsilon'(p)) and mean (epsilon'(m)) strain rates obtained at the basal septum were compared against Emax by linear regression. Emax as well as TDE systolic indices increased during inotropic stimulation with dobutamine and decreased with the infusion of esmolol. A stronger association was found between Emax and epsilon'(p) (r=0.94, P<0.01, y=0.29x+0.46) and epsilon'(m) (r=0.88, P<0.01) than for Sm (r=0.75, P<0.01). CONCLUSIONS: TDE-derived epsilon'(p) and epsilon'(m) are strong noninvasive indices of LV contractility. These indices appear to be more reliable than S(m), perhaps by eliminating translational artifact.