Search NASA⌕ Search

Engineering topics

Thompson, R. W.

Publications and source records attributed to Thompson, R. W..

The gravitational lens system Q0957+561 in the ultraviolet

Photometric and polarimetric observations of both images of the gravitationally lensed quasar Q0957+561 (z(sub em) = 1.41) were obtained in the UV in 1993 with the High Speed Photometer on board the Hubble Space Photometer on board the Hubble Space Telescope. The images exhibited no significant polarization in a bandpass centered on 2770 A (observer's frame); p less than or = 3.2 % (2 sigma upper limit) in each image. The ratio of the flux density in image A to that in image B in late 1993 had a constant valuee, 1.021 +/- 0.008, in four different UV bandpass between 1400 A and 3040 A observer's frame). These results are consistent with the prediction of the gravitation lens interpretation that the photometric ratio of the images measured simultaneously should be independent of frequency. Reprocessed archival spectra of the two images obtained between 1981 and 1983 by the International Ultraviolet Explorer (IUE) show that the photometric ratio of A to B varies between 0.96 and 2.0 in the Ly alpha emission line, and between 0.77 and 1.8 in the O VI lambda 1037 emission line (quasar rest frame). The photometric ratio of A to B at any single epoch is often significantly different in the two emission lines. Accepting the system as a gravitational lens implies that in the quasar the flux in the Ly alpha emsisson line can vary independently of the flux in the 0 IV emission line.

Dolan, J. F.↗

The growth of zeolites A, X and mordenite in space

Zeolites are a class of crystalline aluminosilicate materials that form the backbone of the chemical process industry worldwide. They are used primarily as adsorbents and catalysts and support to a significant extent the positive balance of trade realized by the chemical industry in the United States (around $19 billion in 1991). The magnitude of their efforts can be appreciated when one realizes that since their introduction as 'cracking catalysts' in the early 1960's, they have saved the equivalent of 60 percent of the total oil production from Alaska's North Slope. Thus the performance of zeolite catalysts can have a profound effect on the U.S. economy. It is estimated that a 1 percent increase in yield of the gasoline fraction per barrel of oil would represent a savings of 22 million barrels of crude oil per year, representing a reduction of $400 million in the United States' balance of payments. Thus any activity that results in improvement in zeolite catalyst performance is of significant scientific and industrial interest. In addition, due to their 'stability,' uniformity, and, within limits, their 'engineerable' structures, zeolites are being tested as potential adsorbents to purify gases and liquids at the parts-per-billion levels needed in today's electronic, biomedical, and biotechnology industries and for the environment. Other exotic applications, such as host materials for quantum-confined semiconductor atomic arrays, are also being investigated. Because of the importance of this class of material, extensive efforts have been made to characterize their structures and to understand their nucleation and growth mechanisms, so as to be able to custom-make zeolites for a desired application. To date, both the nucleation mechanics and chemistry (such as what are the 'key' nutrients) are, as yet, still unknown for many, if not all, systems. The problem is compounded because there is usually a 'gel' phase present that is assumed to control the degree of supersaturation, and this gel undergoes a continuous 'polymerization' type reaction during nucleation and growth. Generally, for structure characterization and diffusion studies, which are useful in evaluating zeolites for improving yield in petroleum refining as well as for many of the proposed new applications (e.g., catalytic membranes, molecular electronics, chemical sensors) large zeolites (greater than 100 to 1000 times normal size) with minimum lattice defects are desired. Presently, the lack of understanding of zeolite nucleation and growth precludes the custom design of zeolites for these or other uses. It was hypothesized that the microgravity levels achieved in an orbiting spacecraft could help to isolate the possible effects of natural convection (which affects defect formation) and minimize sedimentation, which occurs since zeolites are twice as dense as the solution from which they are formed. This was expected to promote larger crystals by allowing growing crystals a longer residence time in a high-concentration nutrient field. Thus it was hypothesized that the microgravity environment of Earth orbit would allow the growth of large, more defect-free zeolite crystals in high yield.

Sacco, Albert, Jr.↗

Zeolite crystal growth in space - What has been learned

Three zeolite crystal growth experiments developed at WPI have been performed in space in last twelve months. One experiment, GAS-1, illustrated that to grow large, crystallographically uniform crystals in space, the precursor solutions should be mixed in microgravity. Another experiment evaluated the optimum mixing protocol for solutions that chemically interact ('gel') on contact. These results were utilized in setting the protocol for mixing nineteen zeolite solutions that were then processed and yielded zeolites A, X and mordenite. All solutions in which the nucleation event was influenced produced larger, more 'uniform' crystals than did identical solutions processed on earth.

Sacco, A., Jr.↗

IUE data reduction - The parameterization of the motion of the IUE reseau grids and spectral formats as a function of time and temperature

Improvements are made on IUE data reduction using corrected reseau positions and dispersion constants for temperature variations and secular effects. Models describing the motion of the high dispersion spectral format as a function of THDA alone reduce the scatter in the predicted position of a given wavelength, and scatter is further reduced when a linear dependence on time is also allowed. A correction technique is presented for early data which reduces errors in wavelength assignments from over 30 km/s to less than 3 km/s in high dispersion. The reseau temperature correction helps locate the minimum background signal, centered between the echelle orders. The residual uncertainty of 2 km/s for SWP and 2.7 km/s for LWR makes the wavelength accuracy of time and temperature corrected IUE spectra comparable to that of temperature corrected data from the Copernicus satellite.

Thompson, R. W.↗

High dispersion observations of selected regions in the Orion Nebula

High resolution spectral observations were made of several regions of the Orion Nebula near theta (2) Ori A using the IUE. The positions were selected using a moderate spatial resolution map from a previous low dispersion IUE survery of this section of the nebula. With the SWP and LWR cameras, 28 pectra were obtained of the bright bar, three Taylor-Munch cloudlets, and several surrounding locations. Emission lines of He, C, N, O, Mg, and Si allow a characterization of these cloudlets and of the gas in and around the bar. Small aperture observations provide radial velocity information for the ultraviolet emission of these features. These data show ionization variations from region to region and are suggestive of stellar wind interactions between the cloudlets and theta(2) Ori A.

Boeshaar, G. O.↗

Surface mapping of selected regions in the Orion Nebula

Low dispersion, large aperture, ultraviolet spectra of selected regions in the Orion Nebula were obtained with the International Ultraviolet Explorer (IUE) scientific instrument. Spectra obtained at 35 contiguous locations defining a mosaic within the nebula were used to generate monochromatic images of high spatial resolution at the wavelengths of the ultraviolet emission lines. Image processing techniques were utilized to generate and analyze these ultraviolet surface maps. The imagery at the three wavelengths studied shows definite differences in the spatial distribution of emission from the CII CIII and OII ions. Ways of using the imagery to determine ionization structure and C/O abundance ratios throughout the regions observed are developed, in addition to means of analyzing the extensive continuum measurements in terms of dust scattering characteristics.

Perry, P. M.↗

Effects of temperature fluctuations of IUE data quality

Analysis of IUE calibration lamp images shows that variation in the temperature of the scientific instrument causes shifts in the location of the spectral format with respect to the reseau grid on the detector and in the location of the reseaux themselves. In high dispersion, a camera head amplifier temperature difference of 6C corresponds to a shift of 4 pixels in the spectral format for LWR and 2 pixels for SWP along the dispersion direction. Shifts perpendicular to the disperson (for the same temperature difference) are less than one pixel for both cameras. In low dispersion spectra, the shifts are similar but orthogonal to those described above with the larger motion lying in the direction perpendicular to the dispersion. In both dispersion modes, the observed shifts are apparently independent of wavelength. In high dispersion, the constant pixel shift mimics a constant velocity error.

Thompson, R. W.↗

Ultraviolet /UV/ emission line mapping of selected regions in the Orion Nebula

Digital processing of data from the International Ultraviolet Explorer (IUE) satellite are used to obtain monochromatic mosaic images of the most prominent UV spectra lines at 35 locations in the central region of the Orion Nebula. The image processing techniques include calculations of the spectrograph orientation and the thermal effects, normalization for exposure time, background subtraction, correction for sensitivity variation within the IUE spectrograph aperture, correction to an absolute flux scale, sample interpolation, and display on graphic devices. The resulting UV emission line intensity maps may be used in conjunction with observations of other wavelength regions to determine the spatial distribution of ionization and abundance levels of carbon and oxygen in Orion.

Turnrose, B. E.↗

Preliminary results on the conversion of laser energy into electricity

A preliminary experiment was performed to investigate conversion of 10.6 micron laser energy to electrical energy via a laser-sustained argon plasma. Short-circuit currents of 0.7 A were measured between a thoriated-tungsten emitter and collector electrodes immersed in the laser-sustained argon plasma. Open-circuit voltages of about 1.5 V were inferred from the current-voltage load characteristics. The dominant mechanism of laser energy conversion is uncertain at this time. Much higher output powers appear possible.

Thompson, R. W.↗

A review of the thermoelectronic laser energy converter (TELEC) program at Lewis Research Center

The investigation of the Thermoelectronic Laser Energy Converter (TELEC) concept began with a feasibility study of a 1 megawatt sized TELEC system. The TELEC was to use either cesium vapor or hydrogen as the plasma medium. The cesium vapor TELEC appears to be the more practical device studied with an overall calculated conversion efficiency of greater than 48%. Following this study, a small TELEC cell was fabricated which demonstrated the conversion of a small amount of laser power to electrical power. The cell developed a short circuit current of 0.7 amperes and an open circuit voltage, as extrapolated from volt-ampere curves, of about 1.5 volts.

Alger, D. L.↗

A review of the Thermoelectronic Laser Energy Converter /TELEC/ Program at Lewis Research Center

The investigation of the Thermoelectronic Laser Energy Converter (TELEC) concept at the Lewis Research Center (LeRC) began with a feasibility study of a 1 megawatt sized TELEC system. The TELEC was to use either cesium vapor or hydrogen as the plasma medium. The cesium vapor TELEC appears to be the more practical device studied with an overall calculated conversion efficiency of greater than 48%. Following this study, a small TELEC cell was fabricated which demonstrated the conversion of a small amount of laser power to electrical power. The cell developed a short circuit current of 0.7 amperes and an open circuit voltage, as extrapolated from volt-ampere curves, of about 1.5 volts. Work is now in progress to construct and test a cesium vapor TELEC capable of absorbing 20% of an incident 10 kW, 10.6 micrometer beam, and converting 35% of this power to electrical power.

Alger, D. L.↗

Breadboard development of a fluid infusion system

A functional breadboard of a zero gravity Intravenous Infusion System (IVI) is presented. Major components described are: (1) infusate pack pressurizers; (2) pump module; (3) infusion set; and (4) electronic control package. The IVI breadboard was designed to demonstrate the feasibility of using the parallel solenoid pump and spring powered infusate source pressurizers for the emergency infusion of various liquids in a zero gravity environment. The IVI was tested for flow rate and sensitivity to back pressure at the needle. Results are presented.

Thompson, R. W.↗