Search NASA⌕ Search

Engineering topics

Thorn, C.

Publications and source records attributed to Thorn, C..

Measurement of the neutron cross section on argon between 95 and 720 MeV

We report an extended measurement of the neutron cross section on argon in the energy range of 95-720 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. Compared to an earlier analysis of the same data, this extended analysis includes a reassessment of systematic uncertainties, in particular related to unused wires in the upstream part of the detector. Using this information we doubled the fiducial volume in the experiment and increased the statistics by a factor of 2.4. Here we also shifted the analysis from energy bins to time-of-flight bins. This change reduced the overall considered energy range, but improved the understanding of the energy spectrum of incoming neutrons in each bin. Overall, the new measurements are extracted from a fit to the attenuation of the neutron flux in five time-of-flight regions: 140ns-180ns, 120ns-140ns, 112ns-120ns, 104ns-112ns, 96ns-104ns. The final cross sections are given for the flux-averaged energy in each time-of-flight bin with statistical and systematic (syst) uncertainties: σ(146 MeV) = 0.60 $^{+0.14}_{-0.14}$ ±0.08(syst) b, σ(236 MeV) = 0.72 $^{+0.10}_{-0.10}$ ± 0.04(syst) b, σ(319 MeV) = 0.80 $^{+0.13}_{-0.12}$ ±0.040(syst) b, σ(404 MeV) = 0.74 $^{+0.14}_{-0.09}$ ±0.04(syst) b, σ(543 MeV) = 0.74 $^{±0.09}_{-0.09}$ ± 0.04(syst) b.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Parameterization of electron attachment rate constants for impurities in LArTPC detectors

The ability of free electrons to drift long distances at high velocities in pure liquid argon under an applied electric field has been exploited for the past forty years to implement detectors with increasingly larger volumes for high energy physics research. The attachment of free electrons to impurities in the LAr is an important limit on the free instrumented volume of these extremely large detectors, and impurity concentrations as small as 100 ppt can reduce their resolution and efficiency. In this paper, we summarize the electron attachment rate constants as a function of the applied electric field, for common impurities in LArTPCs, obtained from data in the literature. Here, we further provide analytical functions to parameterize the data, which are useful to compare with new measurements, to model and analyze the performance of existing detectors, and to predict the performance of new detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryogenic User Facilities for R&D on Noble Liquid Detectors and Low Temperature Devices

Cryogenic test facilities are critical infrastructure for physics experiments in a variety of fields, perhaps most notably for particle detection with noble liquid detectors, low-temperature device development, and quantum information research. However, considerable investment and technical knowledge are required to construct and operate such facilities. This white paper discusses proposals for user facilities aimed at broadening the availability of testing capabilities for the scientific community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mini-CAPTAIN liquid argon time projection chamber

This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 20-liter test stand with gas purification for liquid argon research

Here, we describe the design of a 20-liter test stand constructed to study fundamental properties of liquid argon (LAr). Moreover, this system utilizes a simple, cost-effective gas argon (GAr) purification to achieve high purity, which is necessary to study electron transport properties in LAr. An electron drift stack with up to 25 cm length is constructed to study electron drift, diffusion, and attachment at various electric fields. Finally, a gold photocathode and a pulsed laser are used as a bright electron source. The operational performance of this system is reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Summary of the Second Workshop on Liquid Argon Time Projection Chamber Research and Development in the United States

The second workshop to discuss the development of liquid argon time projection chambers (LArTPCs) in the United States was held at Fermilab on July 8-9, 2014. The workshop was organized under the auspices of the Coordinating Panel for Advanced Detectors, a body that was initiated by the American Physical Society Division of Particles and Fields. All presentations at the workshop were made in six topical plenary sessions: i) Argon Purity and Cryogenics, ii) TPC and High Voltage, iii) Electronics, Data Acquisition and Triggering, iv) Scintillation Light Detection, v) Calibration and Test Beams, and vi) Software. This document summarizes the current efforts in each of these areas. It primarily focuses on the work in the US, but also highlights work done elsewhere in the world.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A portable cryostat for the cold transfer of polarized solid HD targets: HDice-I

We developed a device with moveable liquid nitrogen and liquid helium volumes that is capable of reaching over 2 m into the coldest regions of a cryostat or dilution refrigerator and reliably extracting or installing a target of solid, polarized hydrogen deuteride (HD). This Transfer Cryostat incorporates a cylindrical neodymium rare-earth magnet that is configured as a Halbach dipole, which is maintained at 77 K and produces a 0.1 T field around the HD target. Multiple layers provide a hermetic 77 K-shield as the device is used to maintain a target at 2 K during a transfer between cryostats. Our tests with frozen-spin HD show very little polarization loss for either H (-1±2%, relative) or D (0±3%, relative) over typical transfer periods. Multiple target transfers with this apparatus have shown an overall reliability of about 95% per transfer, which is a significant improvement over earlier versions of the device.

42 ENGINEERING↗

LAr1-ND: Testing Neutrino Anomalies with Multiple LArTPC Detectors at Fermilab

This white paper describes LAr1-ND and the compelling physics it brings first in Phase 1 and next towards the full LAr1 program. In addition, LAr1-ND serves as a key step in the development toward large-scale LArTPC detectors. Its development goals will encompass testing existing and possibly innovative designs for LBNE while at the same time providing a training ground for teams working towards LBNE combining timely neutrino physics with experience in detector development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-Baseline Neutrino Experiment (LBNE)

The US department of energy approved the Mission Need (CD-0) for a long baseline neu trino experiment on January 8th 2010. This marked the official start of the LBNE project whose goal is to plan and execute the construction of a next generation neutrino experiment designed to measure neutrino oscillation parameters with a neutrino beam from Fermilab detected in a large detector a mile underground in the former Homestake mine in South Dakota.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗