Search NASA⌕ Search

Engineering topics

Thornton, Brian A.

Publications and source records attributed to Thornton, Brian A..

Can High-Performance Equipment Lead to a Low-Performance Building?

The performance-based compliance alternative available in most energy codes, intended to provide energy efficiency equivalent to that of prescriptive compliance while allowing innovation and design flexibility, can instead result in sub-standard energy performance in both the short and the long term. The potential deficiencies in modeled buildings originate with subtleties in the energy modeling rules, allowing building systems that consume more energy than their real-world, prescriptively-designed counterparts. This performance gap is exacerbated over subsequent decades as less efficient permanent features of the building remain while elements with shorter lives are regularly upgraded in most buildings. This paper summarizes an investigation into the topic for Pacific Northwest National Laboratory and the City of Seattle, including identification of the principal deficiencies exploited in the modeling path, and several potential code amendments that could resolve these deficiencies and establish better equivalency between prescriptive and performance compliance paths. The study, focusing on Seattle and Washington State energy codes, offers lessons and implications for other jurisdictions and energy codes.

Building Energy Codes↗

Preserving Envelope Efficiency in Performance Based Code Compliance

The City of Seattle 2012 Energy Code (Seattle 2014), one of the most progressive in the country, is under revision for its 2015 edition. Additionally, city personnel participate in the development of the next generation of the Washington State Energy Code and the International Energy Code. Seattle has pledged carbon neutrality by 2050 including buildings, transportation and other sectors. The United States Department of Energy (DOE), through Pacific Northwest National Laboratory (PNNL) provided technical assistance to Seattle in order to understand the implications of one potential direction for its code development, limiting trade-offs of long-lived building envelope components less stringent than the prescriptive code envelope requirements by using better-than-code but shorter-lived lighting and heating, ventilation, and air-conditioning (HVAC) components through the total building performance modeled energy compliance path. Weaker building envelopes can permanently limit building energy performance even as lighting and HVAC components are upgraded over time, because retrofitting the envelope is less likely and more expensive. Weaker building envelopes may also increase the required size, cost and complexity of HVAC systems and may adversely affect occupant comfort. This report presents the results of this technical assistance. The use of modeled energy code compliance to trade-off envelope components with shorter-lived building components is not unique to Seattle and the lessons and possible solutions described in this report have implications for other jurisdictions and energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗