Search NASA⌕ Search

Engineering topics

Tillman, J.

Publications and source records attributed to Tillman, J..

Design of Muon Campus full flow purifier for varying operational conditions and horizontal shipping

Constant ingress of impurities in Muon Campus g-2 experiment at Fermilab has resulted in reduction of efficiency of cryogenic expanders and occasional undesired downtime to flush the impurities. Due to insufficiency of current 0.06 kg/s mobile purifier, a full flow purifier is designed to be used in Muon Campus which purifies 0.24 kg/s of Helium throughput of 4 compressors through charcoal bed at 80 K and returns ambient Helium back to the system. The purifier is designed to be operated near liquid Nitrogen temperature during cold operations and up to 400 K during regeneration. Both warm and cold operational range of the purifier has required use of appropriate clearances in design due to expansion and contraction. The vessel of around 5.5 m height which is designed to be operated vertically is to be shipped horizontally. The asymmetrical position of heavy stainless steel heat exchanger in the purifier support frame and 5g vertical load design consideration for shipping has required use of shipping supports and heat exchanger rotational stops to comply with design requirements. FEA of purifier system is performed in cold, warm and shipping cases to verify that the purifier satisfies the design requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rodent Biocompatibility Test Using the NASA Foodbar and Epoxy EP21LV

Epoxy has been used successfully to affix NASA foodbars to the inner walls of the Animal Enclosure Module for past space flight experiments utilizing rodents. The epoxy used on past missions was discontinued, making it necessary to identify a new epoxy for use on the STS-108 and STS-107 missions. This experiment was designed to test the basic biocompatibility of epoxy EP21LV with male rats (Sprague Dawley) and mice (Swiss Webster) when applied to NASA foodbars. For each species, the test was conducted with a control group fed untreated foodbars and an experimental group fed foodbars applied with EP21LV. For each species, there were no group differences in animal health and no statistical differences (P<0.05) in body weights throughout the study. In mice, there was a 16% increase in heart weight in the epoxy group; this result was not found in rats. For both species, there were no statistical differences found in other organ weights measured. In rats, blood glucose levels were 15% higher and both total protein and globulin were 10% lower in the epoxy group. Statistical differences in these parameters were not found in mice. For both species, no statistical differences were found in other blood parameters tested. Food consumption was not different in rats but water consumption was significantly decreased 10 to 15% in the epoxy group. The difference in water consumption is likely due to an increased water content of the epoxy-treated foodbars. Finally, both species avoided consumption of the epoxy material. Based on the global analysis of the results, the few parameters found to be statistically different do not appear to be a physiologically relevant effect of the epoxy material, We conclude that the EP21LV epoxy is biocompatible with rodents.

Tillman, J.↗

Microinstruments for a Low Power, Low Mass Weather Station

Advances in electronics and instrument technology over the past thirty years have enabled a new concept for NASA missions, an evolution from large Voyager-class spacecraft to smaller, less costly Discovery and Explorer missions. By taking advantage of micromachining and micro-instrumentation, this reduction in size can be accomplished without requiring a sacrifice in performance. In some cases, the small payload will enable new types of missions which would be otherwise inconceivable. A microweather station is envisioned as an enabling technology for a network of weather stations on Mars for measuring wind, temperature, pressure, humidity, and aerosol concentration in the Martian planetary boundary layer...

Hoenk, M. E.↗

Three Mars years - Viking Lander 1 imaging observations

The Mutch Memorial Station (Viking Lander 1) on Mars acquired imaging and meteorological data over a period of 2245 martian days (3.3 martian years). This article discusses the deposition and erosion of thin deposits (ten to hundreds of micrometers) of bright red dust associated with global dust storms, and the removal of centimeter amounts of material in selected areas during a dust storm late in the third winter. Atmospheric pressure data acquired during the period of intense erosion imply that baroclinic disturbances and strong diurnal solar tidal heating combined to produce strong winds. Erosion occurred principally in areas where soil cohesion was reduced by earlier surface sampler activities. Except for redistribution of thin layers of materials, the surface appears to be remarkably stable, perhaps because of cohension of the undisturbed surface material.

Arvidson, R. E.↗