Nasa Glenn Icing Research Tunnel: 2018 Change in Drop-Sizing Equations Due to Change in Cloud Droplet Probe Sample Area

Although there has been no physical change to the cloud drop diameters in the NASA Glenn Icing Research Tunnel (IRT), the IRT cloud calibration team now has an improved understanding of the facility’s drop-sizing instrumentation, which has resulted in a recent change to the drop-sizing equations. Only the calculated values given in the previous calibration report have changed. In 2017, IRT staff found reason to believe that since at least 2014, the sample area for its Cloud Droplet Probe (CDP) (Droplet Measurement Technologies, Inc.) has been closer to 0.289 mm2, rather than the user manual’s suggested value of 0.24 mm2. In September 2017, the probe’s sample area was measured both before and after the probe was realigned, and the end sample area was measured to be 0.248 mm2. Following the probe’s realignment, drop size measurements were made in the IRT using the CDP as well as optical array probes OAP–230X and OAP–230Y (Particle Measurement Systems, Inc.). These measurements suggested that 0.289 mm2 was the more accurate value for historical measurements. When the CDP sample area used for calculations was changed from 0.24 to 0.289 mm2, distributions previously reported to have a median volumetric diameter (MVD) between 30 and 100 μm were instead calculated to have MVD values 10 to 18 percent higher. The analyses that led to these conclusions are reported in this paper, as well as the new drop-sizing equations that have been developed for the corrected measurement values. This report contains updates to drop-sizing data for the IRT’s “normal” operating conditions (MVD < 50 μm) and discusses the effects on the IRT’s “large-drop” conditions (Mod1 nozzles, Pair < 10 psig), but it does not include updates to the drop-sizing equations for those large-drop conditions.

Particle sizing↗

The Demonstration of a Light Extinction Tomography System at the NASA Glenn Research Center's Icing Research Tunnel

A prototype light extinction tomography system has been developed for acquiring real-time in-situ icing cloud uniformity and density measurements in the NASA Glenn Research Center's Icing Research Tunnel (IRT). These measurements are currently obtained through periodic manual calibrations of the IRT. These calibrations are time consuming and assume that cloud uniformity and density does not greatly vary between the periodic calibrations. It is envisioned that the new light extinction tomography system will provide the means to make these measurements in-situ in real-time and minimize the need for these manual calibrations. This new system uses the principle of light extinction tomography to measure the spray density and distribution in the test section. The prototype system was installed and successfully demonstrated in the Icing Research Tunnel in early 2018. Data sets were acquired for several standard spray and simulated fault conditions to assess system capability and sensitivity. This paper will describe the prototype light extinction system, the theory behind it, and the results of the demonstration test that was conducted in the IRT.

Test Facility↗

The Demonstration of a Light Extinction Tomography System at the NASA Glenn Research Center's Icing Research Tunnel

A prototype light extinction tomography system has been developed for acquiring real-time in-situ icing cloud uniformity and density measurements in the NASA Glenn Research Center's Icing Research Tunnel (IRT). These measurements are currently obtained through periodic manual calibrations of the IRT. These calibrations are time consuming and assume that cloud uniformity and density does not greatly vary between the periodic calibrations. It is envisioned that the new light extinction tomography system will provide the means to make these measurements in-situ in real-time and minimize the need for these manual calibrations. This new system uses the principle of light extinction tomography to measure the spray density and distribution in the test section. The prototype system was installed and successfully demonstrated in the Icing Research Tunnel in early 2018. Data sets were acquired for several standard spray and simulated fault conditions to assess system capability and sensitivity. This paper will describe the prototype light extinction system, the theory behind it, and the results of the demonstration test that was conducted in the IRT.

Tomography↗

Statistical Process Control and Capability Study on the Water Content Measurements in NASA Glenn's Icing Research Tunnel

The Icing Research Tunnel (IRT) at NASA Glenn Research Center follows the recommended practice for icing tunnel calibration outlined in SAE's ARP5905 document. The calibration team has followed the schedule of a full calibration every five years with a check calibration done every six months following. The liquid water content of the IRT has maintained stability within in the specifications presented to customers that the variation is within +/- 10% of the calibrated, target measurement. With recent measurements and instrumentation errors, a more thorough assessment of error source was desired. By constructing statistical process control charts, the ability to determine how the instrument varies in the short term, mid term, and long term was gained. The control charts offer a view of instrument error, facility error, or installation changes. It was discovered that there was a shift from target to mean baseline thus leading to the study of the overall capability indices of the liquid water content measuring instrument to perform within specifications defined in the IRT. This presentation describes data processing procedures for the Multi-Element Sensor in the IRT, including collision efficiency corrections, canonical correlation analysis, Chauvenet's Criterion for rejection of data, distribution check of data, and mean, median and mode for construction of control charts. Further data is presented to describe the repeatability of the IRT with the Multi-Element Sensor and the ability to maintain a stable process for the defined calibration schedule.

Timko, Emily N.↗

Particle Size Calibration Testing in the NASA Propulsion Systems Laboratory

The particle size characterization portion of the 2017 Propulsion Systems Laboratory (PSL) Cloud Calibration is described. The work focuses on characterizing the particle size distribution of the icing cloud as a function of simulated atmospheric conditions.These results will aid in upcoming ice crystal and supercooled liquid icing tests in PSL. Measurements acquired with the Phase Doppler Interferometer and High Speed Imaging instruments are presented. Experimental results indicate that the particle size distribution is primarily a function nozzle air and water pressures, and that air speed is not a significant effect for ice crystal clouds in PSL and both thermodynamic conditions and air speed are not significant effects for supercooled liquid water clouds in PSL.

Engine Icing↗

Particle Size Calibration Testing in the NASA Propulsion Systems Laboratory

The particle size characterization portion of the 2017 Propulsion Systems Laboratory (PSL) Cloud Calibration is described. The work focuses on characterizing the particle size distribution of the icing cloud as a function of simulated atmospheric conditions.These results will aid in upcoming ice crystal and supercooled liquid icing tests in PSL. Measurements acquired with the Phase Doppler Interferometer and High Speed Imaging instruments are presented. Experimental results indicate that the particle size distribution is primarily a function nozzle air and water pressures, and that air speed is not a significant effect for ice crystal clouds in PSL and both thermodynamic conditions and air speed are not significant effects for supercooled liquid water clouds in PSL.

Engine icing↗

Update on the NASA Glenn Propulsion Systems Lab Icing and Ice Crystal Cloud Characterization (2017)

NASA Glenn's Propulsion Systems Lab, an altitude engine test facility, generates icing clouds with a spray system. While the spray system is used mostly to create ice crystal clouds (Appendix D/P), the 2017 cloud characterization effort added the requirement to produce exactly supercooled liquid clouds in Appendix C and Appendix O. Success was demonstrated to supercool the largest drops at the warmest conditions, but not freeze out the smallest drops at the coldest conditions. This paper documents primarily the total water content characterization methodology and results from an Iso-Kinetic Probe in ice crystals and Multi-Wire sensor in supercooled liquid, along with the cloud uniformity provided by light extinction tomography. Particle size distribution results from High Speed Imaging probes and a Phase Doppler Interferometer are discussed. Also, a new numerical model for tracking the thermodynamics of the air-drop interactions in PSL from the plenum toward the cloud characterization plane are noted. Both of these latter topic are more fully documented in companion papers.

Calibration↗