Search NASA⌕ Search

Engineering topics

Timothy Fahringer

Publications and source records attributed to Timothy Fahringer.

TPSAS-NF1676L-33668-DND

A three-color pyrometer has been developed based on plenoptic imaging technology. Three bandpass filters placed in front of the camera lens allows separate 2D images to be obtained at three different wavelengths. Images were obtained of different black- or grey-bodies including a calibration furnace, a radiation heater, a sooting butane flame and a luminous sulfur match flame. The images were processed to determine 2D temperature distributions. Calibration results in the furnace showed that the instrument could measure temperature with an accuracy and precision of 10 Kelvins between 1100 and 1350 K. Time-resolved 2D measurements of the radiation heater, flame and match are shown.

Paul M Danehy↗

Evaluation of CFD for Simulation of High-Supersonic Control Surface Effectiveness

This is the set of slides describing the CFD and wind-tunnel test studying the control surfaces of the CobraMRV concept for entry, descent, and landing on Mars. Difference between the CFD and wind-tunnel results are highlighted with the intent of showing whether CFD can replace wind-tunnel testing in the high supersonic flight regime.

wind tunnel↗

Recent Development Work with Self-Aligned Focusing Schlieren

A novel compact focusing schlieren instrument has recently been developed that eliminates the need for a separate source and cutoff grid. The technique works by projecting an image of a grid onto a retroreflective surface and then reimaging the projection back onto the original grid. By manipulating the polarization state of the light passing through the instrument, a single Rochon polarizing prism can be used to adjust the schlieren sensitivity by translating it along the instrument’s optical axis, which changes the in-plane offset between the reimaged projection and the original grid. This arrangement makes the instrument inherently self-aligned. Relative to conventional focusing schlieren instruments, which require alignment of a separate source grid and cutoff grid to achieve sensitivity, the setup time required in order to obtain high quality focusing schlieren images is significantly reduced. Further, the self-aligned nature of this instrument makes it insensitive to vibrations and allows for on-the-fly adjustments to field-of-view. In this paper we discuss recent work that has been performed to expand the capabilities of this self-aligned focusing schlieren instrument including: schlieren visualization at extreme angles for optically-restricted test facilities, 3D schlieren visualization using a light field camera, acquisition of high quality focusing schlieren images from facilities with low quality windows, and obtaining focusing schlieren images in full-scale ground test facilities.

Brett Bathel↗

Development of the Model Deformation System at the National Transonic Facility

This paper describes the model deformation system currently being developed for the National Transonic Facility at NASA Langley Research Center. The photogrammetry system uses up to eight network cameras that are time synced with an external hardware trigger. Camera extrinsics are calculated per frame with a bundle adjustment process with coded targets painted to the floor and walls of the test section. We describe our algorithm pipeline including the coded target system for target correspondence between camera views. We also present our future plans for modernizing the system.

Timothy Fahringer↗

Development of the model deformation system at the National Transonic Facility

This paper describes the model deformation system currently being developed for the National Transonic Facility at NASA Langley Research Center. The photogrammetry system uses up to eight network cameras that are time synced with an external hardware trigger. Camera extrinsics are calculated per frame with a bundle adjustment process with coded targets painted to the floor and walls of the test section. We describe our algorithm pipeline including the coded target system for target correspondence between camera views. We also present our future plans for modernizing the system.

Timothy Fahringer↗

Visualization of Freestream Vortices in the NASA Langley 4-Foot Supersonic Unitary Plan Wind Tunnel

Streamwise vortices present in the freestream of the NASA Langley 4-Foot Supersonic Unitary Plan Wind Tunnel have been observed experimentally for the first time. A high-energy, burst-mode laser system was used to conduct time-resolved planar laser Mie scattering in the freestream of this facility. The freestream of the facility was observed over Mach numbers ranging from 2.4 to 4.6 and (unit) Reynolds number between 3.3 × 10 6 to 14.8 × 10 6 1/m. Apparent vortical structures were observed in the tunnel freestream at Mach numbers ≤ 3 with little difference observed for varying Reynolds number. With further-increasing Mach number, protrusive and oscillatory vertical ‘sprite’ structures were observed emanating from the tunnel floor boundary layer. Neither of these structural phenomena have been observed before experimentally in the facility and act to confirm and inform predictions made in computational fluid dynamic simulations of the facility.

Flow visualization↗