Search NASA⌕ Search

Engineering topics

Ting, Chen

Publications and source records attributed to Ting, Chen.

Objected constrained registration and manifold learning: A new patient setup approach in image guided radiation therapy of thoracic cancer

Purpose: The management of thoracic malignancies with radiation therapy is complicated by continuous target motion. In this study, a real time motion analysis approach is proposed to improve the accuracy of patient setup. Methods: For 11 lung cancer patients a long training fluoroscopy was acquired before the first treatment, and multiple short testing fluoroscopies were acquired weekly at the pretreatment patient setup of image guided radiotherapy (IGRT). The data analysis consisted of three steps: first a 4D target motion model was constructed from 4DCT and projected to the training fluoroscopy through deformable registration. Then the manifold learning method was used to construct a 2D subspace based on the target motion (kinetic) and location (static) information in the training fluoroscopy. Thereafter the respiratory phase in the testing fluoroscopy was determined by finding its location in the subspace. Finally, the phase determined testing fluoroscopy was registered to the corresponding 4DCT to derive the pretreatment patient position adjustment for the IGRT. The method was tested on clinical image sets and numerical phantoms. Results: The registration successfully reconstructed the 4D motion model with over 98% volume similarity in 4DCT, and over 95% area similarity in the training fluoroscopy. The machine learning method derived the phase values in over 98% and 93% test images of the phantom and patient images, respectively, with less than 3% phase error. The setup approach achieved an average accumulated setup error less than 1.7 mm in the cranial-caudal direction and less than 1 mm in the transverse plane. All results were validated against the ground truth of manual delineations by an experienced radiation oncologist. The expected total time for the pretreatment setup analysis was less than 10 s. Conclusions: By combining the registration and machine learning, the proposed approach has the potential to improve the accuracy of pretreatment setup for patients with thoracic malignancy.

60 APPLIED LIFE SCIENCES↗

Improvement in Interobserver Accuracy in Delineation of the Lumpectomy Cavity Using Fiducial Markers

Purpose: To determine, whether the presence of gold fiducial markers would improve the inter- and intraphysician accuracy in the delineation of the surgical cavity compared with a matched group of patients who did not receive gold fiducial markers in the setting of accelerated partial-breast irradiation (APBI). Methods and Materials: Planning CT images of 22 lumpectomy cavities were reviewed in a cohort of 22 patients; 11 patients received four to six gold fiducial markers placed at the time of surgery. Three physicians categorized the seroma cavity according to cavity visualization score criteria and delineated each of the 22 seroma cavities and the clinical target volume. Distance between centers of mass, percentage overlap, and average surface distance for all patients were assessed. Results: The mean seroma volume was 36.9 cm{sup 3} and 34.2 cm{sup 3} for fiducial patients and non-fiducial patients, respectively (p = ns). Fiducial markers improved the mean cavity visualization score, to 3.6 {+-} 1.0 from 2.5 {+-} 1.3 (p < 0.05). The mean distance between centers of mass, average surface distance, and percentage overlap for the seroma and clinical target volume were significantly improved in the fiducial marker patients as compared with the non-fiducial marker patients (p < 0.001). Conclusions: The placement of gold fiducial markers placed at the time of lumpectomy improves interphysician identification and delineation of the seroma cavity and clinical target volume. This has implications in radiotherapy treatment planning for accelerated partial-breast irradiation and for boost after whole-breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Object-constrained meshless deformable algorithm for high speed 3D nonrigid registration between CT and CBCT

Purpose: High-speed nonrigid registration between the planning CT and the treatment CBCT data is critical for real time image guided radiotherapy (IGRT) to improve the dose distribution and to reduce the toxicity to adjacent organs. The authors propose a new fully automatic 3D registration framework that integrates object-based global and seed constraints with the grayscale-based ''demons'' algorithm. Methods: Clinical objects were segmented on the planning CT images and were utilized as meshless deformable models during the nonrigid registration process. The meshless models reinforced a global constraint in addition to the grayscale difference between CT and CBCT in order to maintain the shape and the volume of geometrically complex 3D objects during the registration. To expedite the registration process, the framework was stratified into hierarchies, and the authors used a frequency domain formulation to diffuse the displacement between the reference and the target in each hierarchy. Also during the registration of pelvis images, they replaced the air region inside the rectum with estimated pixel values from the surrounding rectal wall and introduced an additional seed constraint to robustly track and match the seeds implanted into the prostate. The proposed registration framework and algorithm were evaluated on 15 real prostate cancer patients. For each patient, prostate gland, seminal vesicle, bladder, and rectum were first segmented by a radiation oncologist on planning CT images for radiotherapy planning purpose. The same radiation oncologist also manually delineated the tumor volumes and critical anatomical structures in the corresponding CBCT images acquired at treatment. These delineated structures on the CBCT were only used as the ground truth for the quantitative validation, while structures on the planning CT were used both as the input to the registration method and the ground truth in validation. By registering the planning CT to the CBCT, a displacement map was generated. Segmented volumes in the CT images deformed using the displacement field were compared against the manual segmentations in the CBCT images to quantitatively measure the convergence of the shape and the volume. Other image features were also used to evaluate the overall performance of the registration. Results: The algorithm was able to complete the segmentation and registration process within 1 min, and the superimposed clinical objects achieved a volumetric similarity measure of over 90% between the reference and the registered data. Validation results also showed that the proposed registration could accurately trace the deformation inside the target volume with average errors of less than 1 mm. The method had a solid performance in registering the simulated images with up to 20 Hounsfield unit white noise added. Also, the side by side comparison with the original demons algorithm demonstrated its improved registration performance over the local pixel-based registration approaches. Conclusions: Given the strength and efficiency of the algorithm, the proposed method has significant clinical potential to accelerate and to improve the CBCT delineation and targets tracking in online IGRT applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗