Development of Gamma-Ray Pixels for an NDSE Detector Array using a GEANT4-Based Response Model
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Tinsley, Jim.
Explore the source record for details and available documents.
The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.
The purpose for the Neutron-Diagnosed Subcritical Experiment (NDSE) Static Test Series at the Nevada National Security Site (NNSS) Area 11 is to develop and validate the capability to make precise and accurate measurements of k eff for Special Nuclear Material (SNM) targets with k eff ~ 0.95.1 The series has now completed six sets of measurements using the deuterium-tritium (DT) Dense Plasma Focus (DPF) neutron source, with a Rocky-Flats-Shells Highly Enriched Uranium (RF HEU) target, to measure the gamma die-away to this purpose. The last of these series, Series V and VI, are the subject of this report. Both series were performed on a target comprised of the Object IV HEU + CH 2 configuration, which is identical to Object II but with smaller DPF collimators that limit the incident neutron flux to the HEU radius.
Presentation addresses preliminary simulations of gamma absorption by plastic scintillators and suggests that improved sensitivity and energy resolution could be achieved by high-Z metal doping of the plastic and by implementing a Compton reconstruction algorithm on the data stream.
Presentation summarizes updates to the NDSE Liquid VI detector design to improve performance, including use of LightTools application to optimize time and sensitivity with "egg crate" mirrored light guides.
Presentation to be given at the Annual SDRD Final Review, Sept. 22, 2016 in Las Vegas at the Great Basin Nevada Support Facility [website: https://nlv-ddsprd1-ws.nts.ops/SDRD/].
Presentation describes proposed 5x5 NSDE detector system designed to improve response times in gamma/neutron liquid detector array.
Annual report to DOE
Presentation describes proposal to develop a 5x5 grid detector system for neutron-diagnosed experiments using 15" x 15" liquid scintillator units.
Associated particle imaging (API) is a powerful technique for special nuclear material (SNM) detection and characterization of fissile material configurations. A sealed-tube neutron generator has been under development by Lawrence Berkeley National Laboratory to reduce the beam spot size on the neutron production target to 1 mm in diameter for a several-fold increase in directional resolution and simultaneously increases the maximum attainable neutron flux. A permanent magnet 2.45 GHz microwave-driven ion source has been adopted in this time-tagged neutron source. This type of ion source provides a high plasma density that allows the use of a sub-millimeter aperture for the extraction of a sufficient ion beam current and lets us achieve a much reduced beam spot size on target without employing active focusing. The design of this API generator uses a custom-made radial high voltage insulator to minimize source to neutron production target distance and to provide for a simple ion source cooling arrangement. Preliminary experimental results showed that more than 100 µA of deuterium ions have been extracted, and the beam diameter on the neutron production target is around 1 mm.