Search NASA⌕ Search

Engineering topics

Tisdale, Jeremy Tyler

Publications and source records attributed to Tisdale, Jeremy Tyler.

Production of desensitized, ultrafine PETN powder

Pentaerythritol tetranitrate (PETN) is a widely studied high explosive (HE), most commonly used in detonator applications. In this work, we use a spray drying technique to manufacture a new “nano-powder” morphology of PETN. The spray dried PETN is several orders of magnitude smaller in particle size than traditionally prepared PETN powders. The spray dried PETN has a mostly spherical and smooth morphology, while traditional crystalline PETN typically has sharp edges and crystal facets. Small-scale sensitivity tests including drop-weight impact, friction, and electrostatic discharge (ESD) indicate the spray dried PETN is less sensitive than traditionally used forms of PETN powders. Furthermore, we also observed no changes in chemical properties (melt temperature and onset of decomposition) after spray drying, and the material remains in the tetragonal, crystalline phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spray Drying of High Explosives [Slides]

Presentation Outline 1. What is spray drying? 2. How can spray drying be utilized for high explosives processing? 3. Literature overview. 4. Examples of current spray drying research done in Q-5. 5. Future plans and outlook for spray drying high explosives.

42 ENGINEERING↗

Methylammonium Lead Tribromide Single Crystal Detectors towards Robust Gamma-Ray Photon Sensing

In recent years, hybrid perovskite single crystalline solid-state detectors have shown promise in γ-ray spectroscopy. Here, the γ-ray photon induced electrical pulses are investigated, which are produced by perovskite solid-state detectors made with the commonly used methylammonium lead tribromide crystals with chlorine incorporation. Under low electric field detector operation, slow pulses generated by γ-rays with average rise times of 65 µs are observed, which decreases to 20 µs when a higher electrical field of 500 V cm -1 is applied. However, the baseline becomes noisy quickly, which prevents collection of clean pulses for spectra construction. Further, by systematically measuring the temperature dependence and current–voltage characteristics, such instability is attributed to the local ion migration under electrical field creating a fluctuating dark noise, which presents a major challenge in perovskite γ-ray detector technologies. It is demonstrated that cycling the bias between positive and negative polarity can stabilize the detector, allowing for longer periods of pulse accumulation for generating energy resolved spectra with resolutions of ≈35% at 59.6 keV and ≈25% at 662 keV at room temperature. The study indicates that the main limiting factors of perovskite-based γ-ray detectors are slow rise times and bias instability. Finally, these challenges must be properly addressed to achieve reproducible, high-resolution γ-ray detection.

47 OTHER INSTRUMENTATION↗