Search NASA⌕ Search

Engineering topics

Titus, C. J.

Publications and source records attributed to Titus, C. J..

The role of Co valence in charge transport in the entropy‐stabilized oxide (Mg 0.2 Co 0.2 Ni 0.2 Cu 0.2 Zn 0.2 )O

Abstract Many of the studies on the entropy‐stabilized oxide (Mg 0.2 Co 0.2 Ni 0.2 Cu 0.2 Zn 0.2 )O have been heavily application‐based. Previous works have studied effects of cation stoichiometry on the entropy‐driven reaction to form a single phase, but a fundamental exploration of the effects of anion stoichiometry and/or redox chemistry on electrical properties is lacking. Using near‐edge X‐ray absorption fine structure (NEXAFS) and electrical measurements, we show that oxidizing thin film samples of (Mg 0.2 Co 0.2 Ni 0.2 Cu 0.2 Zn 0.2 )O affects primarily the valence of Co, leaving the other cations in this high‐entropy system unchanged. This oxidation increases electrical conduction in these thin films, which occurs via small polaron hopping mediated by the Co valence shift from 2+ to a mixed 2+/3+ state. In parallel, we show that bulk samples sintered in an oxygen‐rich atmosphere have a lower activation energy for electrical conduction than those equilibrated in a nitrogen (reducing) atmosphere. Combining feasible defect compensation scenarios with electrical impedance measurements and NEXAFS data, we propose a self‐consistent interpretation of Co redox‐mediated small polaron conduction as the dominant method of charge transfer in this system.

36 MATERIALS SCIENCE↗

Count Rate Optimizations for TES Detectors at a Femtosecond X-ray Laser

Transition-edge sensor microcalorimeters have found success as X-ray detectors at synchrotron light-sources, due to a unique combination of high collecting area and good energy resolution. However, the upcoming generation of free-electron lasers (FELs), such as the Linac Coherent Light Source II, is designed to deliver more than 10 10 photons in a 100 fs pulse at a 100 kHz rate, potentially leading to severe pulse-pileup issues. Here we will demonstrate that, for most relevant science cases, it is possible to mitigate pulse pile-up using simple X-ray filters in a way that takes advantage of the substantial increase in X-ray flux at modern FELs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Error-Correcting Codes for Code-Division Multiplexed TES Detectors

Transition edge sensors (TESs) have proven to be highly sensitive and versatile X-ray spectrometers. Upcoming missions, including Athena X-IFU, will rely on highly multiplexed focal planes where more than 32 TES pixels are read out using a single SQUID amplifier channel. We have implemented an error correction algorithm for code-division multiplexed TES signals that can compensate for potential failures of individual SQUID readout channels and that is both scalable and easily implemented in hardware. We present this algorithm for error correction and show results of laboratory tests to assess algorithm performance at recovering TES channels after a SQUID failure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Spread-Spectrum SQUID Multiplexer

The transition-edge sensor (TES) is a mature, high-resolution x-ray spectrometer technology that provides a much higher efficiency than dispersive spectrometers such as gratings and crystal spectrometers. As larger arrays are developed, time-division multiplexing schemes operating at MHz frequencies are being replaced by microwave SQUID multiplexers using frequency-division multiplexing at GHz frequencies. However, the multiplexing factor achievable with microwave SQUIDs is limited by the high slew rate on the leading edge of x-ray pulses. In this paper, we propose a new multiplexing scheme for high-slew-rate TES x-ray calorimeters: the spread-spectrum SQUID multiplexer, which has the potential to enable higher multiplexing factors, especially in applications with lower photon-arrival rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TES X-ray Spectrometer at SLAC LCLS-II

We are building a transition edge sensor (TES) X-ray spectrometer for the Linac Coherent Light Source (LCLS-II) at SLAC National Accelerator Laboratory (SLAC) to coincide with new upgrades for this free electron laser facility. This new X-ray spectrometer will have 1000 TES pixels with 0.5 eV energy resolution for soft X-rays below 1 keV. Multiplexing will be done with microwave SQUID resonators and new specialized electronic hardware developed at SLAC. This spectrometer will use a dilution refrigerator to achieve lower operating temperatures than previous TES spectrometers and will be coupled to the liquid jet endstation at LCLS-II. The spectrometer is designed to operate at much higher count rates than previous TES X-ray spectrometers to take advantage of the high repetition rate of the LCLS-II. Science applications will utilize the high photon collection efficiency and throughput, high energy resolution, as well as its ability to simultaneously measure its full calibrated energy range.

47 OTHER INSTRUMENTATION↗