Search NASA⌕ Search

Engineering topics

Tolbert, Leon M.

Publications and source records attributed to Tolbert, Leon M..

At least 19 records

Medium-Duty Delivery Truck Integrated Bidirectional Wireless Power Transfer System With Grid and Stationary Energy Storage System Connectivity

Electric vehicles (EVs) can provide power to the grid or buildings similar to distributed energy resources (DER) for energy balancing applications or optimizing the operation of the microgrids in harmony with the other DER assets. This article presents the operating modes of a bidirectional wireless power transfer (WPT) system designed for a medium-duty package delivery vehicle. The WPT system designed for this study can transfer 20 kW of power across 11 in of air gap using custom-designed double-D (DD) couplers with LCC–LCC tuning networks. The proposed system utilizes a 480-V three-phase grid connection, a plug-in hybrid delivery truck with bidirectional WPT, and a stationary energy storage system (SESS) that can be connected to the primary-side dc link. Due to the differences in primary and secondary dc bus voltages, and considering the voltage of the SESS, asymmetric voltage gains were used in the system. Sensitivity analyses of this system with respect to these voltage levels are presented. Five different operating modes of the grid, SESS, and the EV battery are investigated with experimental results. Control algorithms are described for grid-to-vehicle (G2V) and vehicle-to-grid (V2G) operating modes. A bidirectional WPT system is operated with a power factor of 0.99 on the grid side in every operating mode. The EV battery was charged with 20.3 kW with an overall efficiency of 93.02% in the G2V operating mode. Finally, in the V2G operating mode, the WPT system provided 12.82 kW of power back to the grid with an overall efficiency of 89.08%.

25 ENERGY STORAGE↗

Grid Forming Inverter With Increased Short-Circuit Contribution to Address Inverter-Based Microgrid Protection Challenges

Substantial differences in fault levels between grid-tied and islanded modes is one of the primary challenges of microgrid protection. During grid-tied mode, the bulk grid provides significant short-circuit, while during islanded operation the short-circuit magnitude is small due to inverter-based resources limiting their current output close to nominal ratings. Consequently, conventional distribution protection strategies based on overcurrent cannot reliably protect microgrids when operating in islanded mode. Fuses and circuit breakers are particularly affected because of their inverse characteristics. Presently, the absence of affordable solutions for protecting microgrids in islanded mode leads to microgrids shutting down during electrical faults. The contribution of this article is two-fold. The first innovation proposes specific hardware modifications to grid-forming inverters to increase their short-circuit current during electrical faults. The second innovation introduces a novel control strategy designed to preserve control stability margins even when the grid-filter saturates, ensuring sinusoidal output currents under normal and fault conditions. Through experimental results, the inverter with the proposed modifications can provide more than three-times its nominal current during electrical faults. For the prototype testbed, this was sufficient to enable the use of traditional legacy overcurrent protection, achieving the fuse-to-relay and relay-to-relay minimum coordination time for the line-to-ground, line-to-line to ground, and three-phase electrical faults.

42 ENGINEERING↗

Sensitivity Analysis of a Polyphase Wireless Power Transfer System under Off-Nominal Conditions

Misaligned and/or variable coil airgaps cause coupling coefficient variation in wireless power transfer (WPT) systems, resulting in a decrease in the system’s transmitted power and efficiency. This paper presents sensitivity analyses of a three-phase, Y-Y connected, series-tuned WPT system in the frequency domain in terms of several different electric vehicle wireless charging off-nominal conditions (misalignments in Δ x and Δ y directions, change of airgap Δ z , and the roll Δψ, pitch Δθ, and yaw ΔΦ angles) as specified in Society of Automotive Engineers (SAE) J2954 Standard. Coil inductance matrices were obtained by measuring the self- and mutual inductances of the primary and secondary coil phase windings at variable airgap classes (from 5 cm to 30 cm) for five different charging positions as identified in SAE J2954. These 6 × 6 inductance matrices were used in sensitivity and Plexim/PLECS simulation analyses. The sensitivity of the WPT system was analyzed analytically using the input impedance and phase angle, voltage gain, current gain, quality factor, and coupling coefficient parameters of the series-tuned WPT system. The results were confirmed experimentally on a 50 kW WPT system.

42 ENGINEERING↗

PCB-on-DBC GaN Power Module Design with High-Density Integration and Double-Sided Cooling

Lateral gallium nitride (GaN) high-electron-mobility transistors (HEMTs) present better electrical characteristics compared to silicon or silicon carbide devices such as high switching speed and low gate charge, but also present additional challenges on the module design. Here, this paper discusses a high-density GaN power module with double-sided cooling, low inductance, on-package decoupling capacitors, and integrated gate drivers. The GaN dies as well as the gate drive are sandwiched between the printed circuit board (PCB) and direct bonded copper (DBC) substrate to achieve compact loop and double-sided cooling effect. Design considerations and thermal performance are analyzed. A module assembly procedure is presented utilizing the layer-by-layer attachment process. Finally, a 2.7 cm x 1.8 cm half-bridge GaN power module is fabricated and tested, achieving a low power-loop inductance of 1.03 nH, and the overshoot voltage of the switching waveform is less than 5% under a 400-V/25-A double-pulse test. The thermal resistance is 0.32 K/W, verified by simulation and experimental results. The design and assembly process can be generalized and applied to high power applications to achieve high power density and high performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast Quasi-Static Time-Series Simulation for Accurate PV Inverter Semiconductor Fatigue Analysis with a Long-Term Solar Profile

Power system simulations with long-term data typically have large time steps varying from one second to a few minutes. However, for PV inverter semiconductors, the minimum thermal stress cycle occurs over the fundamental grid frequency (50 or 60 Hz). This requires the time step of the fatigue simulation to be around 100 µs. This small time step requires long computation times to process yearly power production profiles. This paper proposes a fast fatigue simulation for inverter semiconductors using the quasi-static time series (QSTS) simulation concept. The proposed simulation calculates the steady state of the semiconductor junction temperature by using a Fast Fourier Transform (FFT). The small thermal cycling during a switching period and even over the fundamental waveform is disregarded to further accelerate the simulation speed. The resulting time step of the fatigue simulation is 15 minutes, which is consistent with the solar dataset. The error of the proposed simulation is 0.16% compared to the fatigue simulation results using the complete thermal stress profile. A PV inverter that responds to a Transactive Energy System (TES) is simulated to demonstrate the use of the proposed fatigue simulation. The proposed simulation has the potential to co-simulate with system level simulation tools that also adopt the QSTS concept.

Liu, Yunting↗

Methods, systems, and computer readable media for protecting and controlling a microgrid with a dynamic boundary

Methods, systems, and computer readable mediums for protecting and controlling a microgrid with a dynamic boundary are disclosed. One method includes detecting a fault in a microgrid that includes a dynamic point-of-common-coupling (PCC), in response to determining that the microgrid is operating in a grid-connected mode, isolating the fault by tripping a microgrid side smart switch and a grid side smart switch that are located immediately adjacent to the fault, initiating the reclosing of the grid side smart switch, and initiating the reclosing for the microgrid side smart switch via resynchronization if the grid side smart switch is successfully reclosed, and in response to determining that the microgrid is operating in an islanded mode, isolating the fault by tripping a microgrid side smart switch that is located immediately adjacent to the fault, and initiating the reclosing of the microgrid side smart switch.

Wang, Fei↗

Quasi-Static Time Series Fatigue Simulation for PV Inverter Semiconductors with Long-Term Solar Profile

Power system simulations with long-term data tend to have large time steps varying from one second to a few minutes. However, for PV inverter semiconductors, the minimum thermal stresses cycle is with line frequency. This requires the time step of the fatigue simulation to be much smaller than the line period. This small time step results in poor simulation speed, especially for long-term simulations. This paper proposes a fast fatigue simulation for inverter semiconductors using the quasi-static time series (QSTS) simulation concept. The fatigue analysis typically focuses on the peak and valley values of a strain and neglect the transients from peaks to valleys. The proposed simulation utilizes this property of fatigue analysis and calculates the steady state of the semiconductor junction temperature only. The resulting time step of the fatigue simulation is 15 minutes, which is consistent with the solar dataset without losing accuracy.

fast simulation↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Instability Issue of Paralleled Dies in an SiC Power Module in Solid-State Circuit Breaker Applications

Paralleled dies in a power module could have instability issues during high current switching transients. Here, the instability is caused by the differential-mode oscillation among paralleled MOSFETs. Conventional analyses of paralleled MOSFETs’ stability are normally limited to a single operating point, which ignores the influences of the switching trajectory and nonlinear device parameters on stability. This article reveals that the switching trajectory can significantly influence parallel stability. The analysis is improved by solving eigenvalues of state-space modeling system matrices of all operating points that the switching trajectory goes through considering nonlinear device parameters. Higher voltage and current stresses result in greater real parts of complex eigenvalues, which explains why the paralleled MOSFETs are more unstable with higher voltage and current stresses. To improve stability in solid-state circuit breaker applications, we propose a method to manipulate the switching trajectory to avoid the unstable region where the conventional hard switching trajectory normally goes through. Experimental results show that the turn- off current capability can be increased from ~five times of rated current with the gate oscillation using the conventional turn- off trajectory to ~ten times of rated current without the gate oscillation using the optimal turn- off trajectory.

42 ENGINEERING↗

DC-Saturated Continuously Variable Series Reactors (CVSRs) for Power Flow Control in Power Transmission Systems

This paper proposes a novel continuously variable series reactor (CVSR) based on a dc current controller (DCC) to manage power flow in transmission systems. There are three major contributions. First, the three-dimensional electromagnetic interaction has been comprehensively analyzed to extend the understanding beyond the conventional 2D relationship. Second, a high-fidelity reluctance model of the CVSR with an improved DCC model is proposed and implemented. To overcome the fundamental concern for the system modeling, the DCC has been modeled as an ideal current source in parallel with an output impedance. Additionally, the induced back-EMF can be precisely projected which provides critical design guidelines for the DCC. Third, inspired by the theoretical analysis and modeling, a reliable high power DCC converter is designed accordingly to interface with kV-level back-EMF and supply kA-level dc current for a 115 kV/1500 A CVSR. Experiments are conducted in a practical transmission demonstration system. When the ac current in the transmission system varies from zero to 1500 A, experimental results show that the proposed CVSR can continuously regulate the reactance from 1.6 Ω to 5 Ω, validating the effectiveness of the proposed system design and modeling methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Primary Frequency Control Using Motor Drives for Short Term Grid Disturbances

Industrial motor systems make up a quarter of all electric sales in the United States. Variable speed drives (VSDs) can provide energy efficiency savings to the customer by regulating motor speed based on specific and varying needs. In addition to the benefits provided to the customer, VSDs can provide support to the grid through ancillary services. The Center for Ultra-Wide-Area Resilient Electric Energy Transmission Networks (CURENT) developed a power electronics converter-based grid emulator to allow testing of various power system architectures and demonstration of key technologies in monitoring, control, actuation, and visualization. This paper proposes using an active front-end VSD's connected motor load to provide frequency regulation to a large scale power grid. Each part of the emulator is described including motor and power electronics model and control. The proposed frequency regulation is implemented in VSDs and modeled in both a transmission system in EMTDC/PSCAD and verified on CURENT's hardware testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗