Direct 400 Vdc to 1 Vdc power conversion with input series output parallel connection for data center power supplies

Data centers consume an ever-increasing amount of electricity because of the rapid growth of cloud computing and digital information storage. A high voltage point of load (HV POL) converter is proposed to convert the 400-VDC distribution voltage to 1-VDC within a single stage to increase the power conversion efficiency. A six-phase input series output parallel (ISOP) connected structure is implemented for the HV POL. The symmetrical controlled half bridge current doubler is selected as the converter topology in the ISOP structure. The full load efficiency is improved by 4% points compared with state of the art products. A voltage compensator has been designed in order to meet the strict dynamic voltage regulation requirement. A laboratory prototype has been built, and experimental results have been provided to verify the proposed HV POL with a single power conversion stage can meet the dynamic voltage regulation requirement for an on-board power supply with higher efficiency compared to the conventional architecture.

Cui, Yutian↗

Online condition monitoring based dead-time compensation for high frequency SiC voltage source inverter

Dead-time, device output capacitance, and other non-ideal characteristics cause voltage error for the midpoint PWM voltage of the semiconductor phase-leg employed in a voltage-source inverter (VSI). Voltage-second balancing is a well-known concept to mitigate this distortion and improve converter power quality. This paper proposes a unique voltage-second balancing scheme for a SiC based voltage source inverter using online condition monitoring of turn-off delay time and drain-source voltage rise/fall time. This data is sent to the micro-controller to be used in an algorithm to actively adjust the duty cycle of the input PWM gate signals to match the voltage-second of the non-ideal output voltage with an ideal output voltage-second. The monitoring system also allows for this implementation to eliminate the need for precise current sensing and allows for the implementation to be load independent. Dynamic current sensing is still a developing technology, and each load has a unique effect on the output voltage distortion. Test results for a 1 kW half-bridge inverter implementing this monitoring system and voltage-second balancing scheme show a 70% enhancement on the error against the ideal fundamental current value of the output current and a 2% THD improvement on the output current low frequency harmonics.

Dyer, Jacob↗

Short circuit characterization of 3rdgeneration 10 kV SiC MOSFET

The short circuit performance of a 3 rd generation 10 kV/20 A SiC MOSFET with short channel is characterized in this paper. The platform consisting of a phase-leg configuration, which can test both hard switching fault (HSF) and fault under load (FUL) types of fault, is introduced in detail. A Si IGBT based solid state circuit breaker is developed for short circuit test. The short circuit protection having a response time of 1.5 μs is validated by the test platform. The short circuit characteristics for both the HSF and FUL types at 6 kV DC-link are presented and analyzed.

Ji, Shiqi↗

Dead-time optimization for SiC based voltage source converters using online condition monitoring

This paper introduces a dead-time optimization technique for a 2-level voltage source converter (VSC) using turn-off transition monitoring. Dead-time in a VSC impacts power quality, reliability, and efficiency. Silicon carbide (SiC) based VSCs are more sensitive to dead-time from increased reverse conduction losses and turn-off time variability with operating conditions and load characteristics. An online condition monitoring system for SiC devices has been developed using gate drive assist circuits and a micro-controller. It can be leveraged to monitor turn-off time and indicate the optimal dead-time in each switching cycle of any converter operation. It can also be used to specify load current polarity, which is needed for dead-time optimization in an inverter. This is an important distinction from other inverter dead-time elimination/optimization schemes as current around the zero current crossing is hard to accurately detect. A 1kW half-bridge inverter was assembled to test the turn-off time monitoring and dead-time optimization scheme. Results show 91% reduction in reverse conduction power losses in the SiC devices compared to a set dead-time of 500ns switching at 50 kHz.

Dyer, Jacob↗

Single-Phase On-Board Bidirectional PEV Charger for V2G Reactive Power Operation

This paper presents the design and implementation of a single-phase on-board bidirectional plug-in electric vehicle (PEV) charger that can provide reactive power support to the utility grid in addition to charging the vehicle battery. The topology consists of two-stages: a full-bridge ac-dc boost converter; and a half-bridge bidirectional dc-dc converter. The charger operates in two quadrants in the active-reactive power (PQ) power plane with five different operation modes (i.e., charging-only, charging-capacitive, charging-inductive, capacitive-only, and inductive-only). This paper also presents a unified controller to follow utility PQ commands in a smart grid environment. The cascaded two-stage system controller receives active and reactive power commands from the grid, and results in line current and battery charging current references while also providing a stable dynamic response. The vehicle's battery is not affected during reactive power operation in any of the operation modes. Finally, testing the unified system controller with a 1.44 kVA experimental charger design demonstrates the successful implementation of reactive power support functionality of PEVs for future smart grid applications.

battery charger↗

Three-Phase Modular Cascaded H-Bridge Multilevel Inverter with Individual MPPT for Grid-Connected Photovoltaic Systems

A three-phase modular cascaded H-bridge multilevel inverter for a grid-connected photovoltaic (PV) system is presented in this paper. To maximize the solar energy extraction of each PV string, an individual maximum power point tracking (MPPT) control scheme is applied, which allows the independent control of each dc-link voltage. PV mismatches may introduce unbalanced power supplied to the three-phase system. To solve this issue, a control scheme with modulation compensation is proposed. The three-phase modular cascaded multilevel inverter prototype has been built. Each H-bridge is connected to a 185 W solar panel. Simulation and experimental results are presented to validate the proposed ideas.

Xiao, Bailu↗

Lifetime Prediction of IGBT in a STATCOM Using Modified-Graphical Rainflow Counting Algorithm

Rainflow algorithms are one of the best counting methods used in fatigue and failure analysis [17]. There have been many approaches to the rainflow algorithm, some proposing modifications. Graphical Rainflow Method (GRM) was proposed recently with a claim of faster execution times [10]. However, the steps of the graphical method of rainflow algorithm, when implemented, do not generate the same output as the four-point or ASTM standard algorithm. A modified graphical method is presented and discussed in this paper to overcome the shortcomings of graphical rainflow algorithm. A fast rainflow algorithm based on four-point algorithm but considering point comparison than range comparison is also presented. A comparison between the performances of the common rainflow algorithms [6-10], including the proposed methods, in terms of execution time, memory used, and efficiency, complexity, and load sequences is presented. Finally, the rainflow algorithm is applied to temperature data of an IGBT in assessing the lifetime of a STATCOM operating for power factor correction of the load. From 5-minute data load profiles available, the lifetime is estimated to be at 3.4 years.

Gopi Reddy, Lakshmi Reddy↗

Reliability of IGBT in a STATCOM for Harmonic Compensation and Power Factor Correction

With smart grid integration, there is a need to characterize reliability of a power system by including reliability of power semiconductors in grid related applications. In this paper, the reliability of IGBTs in a STATCOM application is presented for two different applications, power factor correction and harmonic elimination. The STATCOM model is developed in EMTP, and analytical equations for average conduction losses in an IGBT and a diode are derived and compared with experimental data. A commonly used reliability model is used to predict reliability of IGBT.

Gopi Reddy, Lakshmi Reddy↗

Smaller, faster, tougher

Silicon has long been the semiconductor of choice for such power electronics. But soon this ubiquitous substance will have to share the spotlight. Devices made from silicon carbide (SiC)-a faster, tougher, and more efficient alternative to straight silicon-are beginning to take off. Simple SiC diodes have already started to supplant silicon devices in some applications. And over the last few years, they've been joined by the first commercially available SiC transistors, enabling anew range of SiC-based power electronics. What's more, SiC wafer manufacturers have steadily reduced the defects in the material while increasing the wafer size, thus driving down the prices of SiC devices. Last year, according to estimates made by wafer maker Cree, the global market for silicon carbide devices topped US $100 million for the first time.

36 MATERIALS SCIENCE↗

Investigation on the parallel operation of discrete SiC devices

This paper presents an analysis of single discrete SiC JFET and BJT devices and their parallel operation. The static and dynamic characteristics of the devices were obtained over a wide range of temperature to study the scaling of device parameters.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

ORNL Laboratory Directed Research and Development Program FY 2008 Annual Report

The Oak Ridge National Laboratory (ORNL) Laboratory Directed Research and Development (LDRD) Program reports its status to the U.S. Department of Energy (DOE) in March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the Laboratory Director broad flexibility for program implementation. LDRD funds are obtained through a charge to all Laboratory programs. This report includes summaries all ORNL LDRD research activities supported during FY 2008. The associated FY 2008 ORNL LDRD Self-Assessment (ORNL/PPA-2008/2) provides financial data and an internal evaluation of the program’s management process.

08 HYDROGEN↗

A Framework to Quantify the Economic Impact from Local VAR Compensation

It is generally accepted that reactive power (or Var) compensation will bring benefits for utilities and industrial customers by providing local voltage and power factor support. However, there is a lack of a systematic approach to quantitatively identify the economic benefit. In addition, with deregulation and restructuring, it is important to indicate the amount of benefit that each market participant may potentially receive given the right price signals. If such information can be easily obtained and presented, it will be more convenient for decision-markers to determine the cost benefit sharing of installing a Var compensator. The vision of this paper is to lay out a possible method for quantitatively evaluating the benefits from local reactive power compensation. The approach is to quantify the benefits into several categories such as reduced losses, shifting reactive power flow to real power flow, and increased transfer. The calculation of these benefits are illustrated with a simple two-bus power system model and then presented with a more complicated model using Optimal Power Flow to calculate the benefits. Simulation on the more complex system is conducted with seven buses in two areas. The simulation results show that the possible economic benefits can be significant, if compared with capacity payments to central generators or payment of power factor penalties applied by utilities. The potential economic value of local Var compensation may give various parties in electricity supply, delivery and end-use consumption a better understanding of the Var benefits to assist their cost-benefit analysis for Var compensation installation. Sensitivity analysis is also provided to illustrate that the benefits may not be monotonically increasing. Also, this paper suggests that the future reactive power market should consider local Var providers or other way to encourage load Var capability, since local Var benefit is significant.

24 POWER TRANSMISSION AND DISTRIBUTION↗