Search NASA⌕ Search

Engineering topics

Tomita, H

Publications and source records attributed to Tomita, H.

Development of neutron measurement in high gamma field using new nuclear emulsion

To precisely measure the neutron emissions from a spent fuel assembly of a fast breeder reactor, we formed nuclear emulsions based on a non-sensitized Oscillation Project with Emulsion tracking Apparatus (OPERA) film with AgBr grain sizes of 60, 90, and 160 nm. The efficiency for {sup 252}Cf neutron detection of the new emulsion was calculated to be 0.7 x 10{sup -4}, which corresponded to an energy range from 0.3 to 2 MeV and was consistent with a preliminary estimate based on experimental results. The sensitivity of the new emulsion was also experimentally estimated by irradiating with 565 keV and 14 MeV neutrons. The emulsion with an AgBr grain size of 60 nm had the lowest sensitivity among the above three emulsions but was still sensitive enough to detect protons. Furthermore, the experimental data suggested that there was a threshold linear energy transfer of 15 keV/{mu}m for the new emulsion, below which no silver clusters developed. Further development of nuclear emulsion with an AgBr grain size of a few tens of nanometers will be the next stage of the present study. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of neutron spectrometer toward deuterium plasma diagnostics in LHD

Neutron spectrometer based on coincident counting of associated particles has been developed for deuterium plasma diagnostics on Large Helical Device (LHD) at the National Institute for Fusion Science. Efficient detection of 2.5 MeV neutron with high energy resolution would be achievable by coincident detection of a scattered neutron and a recoiled proton associated with an elastic scattering of incident neutron in a plastic scintillator as a radiator. The calculated neutron spectra from deuterium plasma heated by neutral beam injection indicate that the energy resolution of better than 7% is required for the spectrometer to evaluate energetic deuterium confinement. By using a prototype of the proposed spectrometer, the energy resolution of 6.3% and the detection efficiency of 3.3x10{sup -7} count/neutron were experimentally demonstrated for 2.5 MeV monoenergetic neutron, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fusion product diagnostics planned for Large Helical Device deuterium experiment

Deuterium experiment on the Large Helical Device (LHD) is now being planned at the National Institute for Fusion Science. The fusion product diagnostics systems currently considered for installation on LHD are described in this paper. The systems will include a time-resolved neutron yield monitor based on neutron gas counters, a time-integrated neutron yield monitor based on activation techniques, a multicollimator scintillation detector array for diagnosing spatial distribution of neutron emission rate, 2.5 MeV neutron spectrometer, 14 MeV neutron counter, and prompt {gamma}-ray diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DMTPC: A dark matter detector with directional sensitivity

By correlating nuclear recoil directions with the Earth's direction of motion through the Galaxy, a directional dark matter detector can unambiguously detect Weakly Interacting Massive Particles (WIMPs), even in the presence of backgrounds. Here, we describe the Dark Matter Time-Projection Chamber (DMTPC) detector, a TPC filled with CF{sub 4} gas at low pressure (0.1 atm). Using this detector, we have measured the vector direction (head-tail) of nuclear recoils down to energies of 100 keV with an angular resolution of {<=}15 deg. To study our detector backgrounds, we have operated in a basement laboratory on the MIT campus for several months. We are currently building a new, high-radiopurity detector for deployment underground at the Waste Isolation Pilot Plant facility in New Mexico.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual Study on New Isotope Analysis Technique with Resonance Ionization Mass Spectrometry Using Inductively Coupled Plasma as an Atomic Source (ICP-RIMS)

We have proposed the novel isotope analysis technique with Resonance Ionization Mass Spectrometry using Inductively Coupled Plasma as an atomic source (ICP-RIMS). Each component of ICP-RIMS is conceptually designed. We conclude that the orthogonal acceleration time-of-flight mass spectrometer (oa-TOF-MS) driven by a high-repetition-rate pulsed laser would be suitable system for ICP-RIMS. We, additionally, suggest that the first vacuum stage of the vacuum interface, which is between the sampling and skimmer cones, is desired to maintain as low pressure as possible in order to suppress the Doppler broadening and to skim the supersonic jet effectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cavity Ring-down Spectroscopy for Carbon Isotope Analysis with 2 {mu}m Diode Laser

We have made a prototype based on CRDS with 2 {mu}m diode laser for carbon isotope analysis of CO{sub 2} in air. The carbon isotope ratio was obtained to be (1.085{+-}0.012)x10{sup -2} which shows good agreement with the isotope ratio measured by the magnetic sector-type mass spectrometer within uncertainty. Hence, we demonstrated the carbon isotope analysis based on CRDS with 2 {mu}m tunable diode laser.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Isotope Analysis Based on Laser Induced Fluorescence

We have proposed Laser Induced Fluorescence analysis using Doppler Shift of laser ablated atoms for Isotope Analysis (LIF-DS-IA). This isotope analysis is expected to have a small mass discrimination effect because the detection target is fluorescence photons instead of ions, which distort the measured isotope ratio by the space charge effect. We demonstrate this technique to be feasible through the model calculations. We experimentally confirmed the fundamental behavior in LIF-DS-IA that the shift in the irradiating laser frequency corresponds to that of peak position in the time domain LIF spectra. The reason of poor mass resolution in the present system was considered to be inadequate definition in the field of view of the fluorescence detector.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision in Strontium Isotope Measurements by Laser Ablation Assisted Resonance Ionization Mass Spectrometry

We have investigated the precision of strontium isotope analysis by Laser Ablation-assisted Resonance Ionization Mass Spectrometry(LA-RIMS). We have confirmed that the mass discrimination effect on the {sup 87}Sr/{sup 86}Sr measurement was reduced by the internal correction method. For the present system, the precision of the isotope ratio of {sup 87}Sr/{sup 86}Sr has been estimated to be 0.6%(1{sigma}). The precision has been limited by the fluctuations with a time scale of less than 10 s.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study on Mass Discrimination Effect of Resonance Ionization Mass Spectrometry Using an Inductively Coupled Plasma as an Atomic Source (ICP-RIMS)

We have proposed a novel concept of Resonance Ionization Mass Spectrometry using an Inductively Coupled Plasma as an Atomic Source (ICP-RIMS). Isotope ratio analysis using ICP-RIMS is expected to be a convenient and precise technique with high throughput. However, the mass discrimination effect caused from difference in kinetic energy of neutral atoms in ICP-RIMS is crucial for precise isotope analysis. We, therefore, investigated the atom kinetic energy distribution introduced into the laser ionization region. The mass-dependent kinetic energy was confirmed in the initial kinetic energy distributions. We preliminary estimated a mass discrimination effect caused by mass-dependent kinetic energy in ICP-RIMS for various detector sizes. We proposed that this effect can be suppressed by selecting the appropriate detector size and adopting the scanning mode of the deflecting voltage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tunability of Injection Seeded High-Repetition Rate Ti:Sapphire Laser Far Off the Gain Peak

We have investigated a tunability of a high-repetition rate Ti:Sapphire laser seeded off the gain peak. By applying a birefringent filter, the 7 kHz injection seeded Ti:Sapphire laser system was operated with the average seeding efficiency of over 90% and the output power of over 1 W on the spectral range of 900-930 nm. We conclude that the birefringent filter suited for widely tunable operation of the injection seeded Ti:Sapphire laser system operated at high repetition rate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Selective Isotope Determination of Uranium using HR-RIMS

The detection of lowest abundances of the ultra trace isotope {sup 236}U in environmental samples requires an efficient detection method which allows a high elemental and isotopic selectivity to suppress neighbouring isotopes of the same element and other background. High Resolution Laser Resonance Ionization Mass Spectrometry (HR-RIMS) uses the individual electron structure of each isotope to provide an outstanding element and isotope selective ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗