Diagnosing Inertial Confinement Fusion Ignition
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Tommasini, R.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We are reporting on a series of indirect-drive 0.9-scale CH capsule implosions (inner radius = 840 μm) fielded in low gas-fill (0.6 mg/cm 3 ) hohlraums of 6.72 mm diameter at the National Ignition Facility. Thanks to the 11%-reduction of the capsule size at a given hohlraum diameter compared to previously tested full-scale capsules, we achieved good hot spot symmetry control near 33% cone-fraction and without the need to invoke cross beam energy transfer. As a result, we achieved a hot spot pressure of 280 ± 40 Gbar, which is the highest pressure demonstrated in layered DT implosions with CH capsules to date. Pushing this design to higher velocity resulted in a reduction of neutron yield. Highly resolved capsule simulations suggest that higher Au M-shell preheat resulted in an increase in Atwood number at the ablator–ice interface, which leads to increased fuel-ablator instability and mixing. The results reported here provide important scaling information for next-generation CH designs.
The goals of the Mix Campaign are to determine how mix affects performance, locate the "mix cliff", locate the source of the mix, and develop mitigation methods that allow performance to be increased. We have used several different drive pulse shapes and capsule designs in the Mix Campaign, to understand sensitivity to drive peak power, level of coast, rise time to peak power, adiabat, and dopant level in the capsule. Ablator material mixing into the hot spot has been shown conclusively with x-ray spectroscopy. The observed neutron yield drops steeply when the hot spot mix mass becomes too large. The mix appears to be driven by ablation- front Rayleigh-Taylor instabilities. A high foot, higher adiabat drive has a more stable ablation front and has allowed the mix mass in the hot spot to be reduced significantly. We found two recent high foot shots achieved neutron yields > 10 15 and measured neutron yield over clean 1D simulation (YOC) > 50%, which was one of the central goals of the Mix Campaign.
Abstract not provided
Abstract not provided
Abstract not provided
Areal density non-uniformities seeded by time-dependent drive variations and target imperfections in Inertial Confinement Fusion (ICF) targets can grow in time as the capsule implodes, with growth rates that are amplified by instabilities. Here, we report on the first measurements of the perturbations on the density and areal density profiles induced by the membranes used to hold the capsule within the hohlraum in indirect drive ICF targets. The measurements are based on the reconstruction of the ablator density profiles from 2D radiographs obtained using pinhole imaging coupled to area backlighting, as close as 150 ps to peak compression. Our study shows a clear correlation between the modulations imposed on the areal density and measured neutron yield, and a 3× reduction in the areal density perturbations comparing a high-adiabat vs. low-adiabat pulse shape.
Abstract not provided
Not Available
Recently developed diagnostic techniques at LLNL require recording backlit images of extremely dense imploded plasmas using hard x-rays, and demand the detector to be sensitive to photons with energies higher than 50 keV [R. Tommasini et al., Phys. Phys. Plasmas 18, 056309 (2011); G. N. Hall et al., “AXIS: An instrument for imaging Compton radiographs using ARC on the NIF,” Rev. Sci. Instrum. (these proceedings)]. To increase the sensitivity in the high energy region, we propose to use a combination of two MCPs. The first MCP is operated in a low gain regime and works as a thick photocathode, and the second MCP works as a high gain electron multiplier. We tested the concept of this dual MCP configuration and succeeded in obtaining a detective quantum efficiency of 4.5% for 59 keV x-rays, 3 times larger than with a single plate of the thickness typically used in NIF framing cameras.
Abstract not provided
Abstract not provided
Abstract not provided
Abstract not provided
Explore the source record for details and available documents.