Search NASA⌕ Search

Engineering topics

Tong, R. H.

Publications and source records attributed to Tong, R. H..

Recent advance progress of HL-3 experiments

Since the first plasma realized in 2020, a series of key systems on HL-3 (known as HL-2M before) tokamak have been equipped/upgraded, including in-vessel components (the first wall, lower divertor, and toroidal cryogenic/water-cooling/baking/glow discharge systems, etc.), auxiliary heating system of 11 MW, and 28 diagnostic systems (to measure the plasma density, electron temperature, radiation, magnetic field, etc.). Magnet field systems were commissioned firstly for divertor plasma discharges. During the 2nd experimental campaign of HL-3 tokamak, several great progresses have been achieved. Firstly, the successful operation with plasma current larger than 1 MA was achieved under a divertor configuration. Secondly, the advanced divertor concept with two distinct snowflake configurations was realized. It is found that the distribution of ion saturation current and heat flux on bottom plate becomes wide due to magnetic surface expansion, demonstrating the advantage of such configuration in the heat flux mitigation. In addition, using the combination of NBI, ECRH and LHCD, the standard sawtoothing high confinement mode of megampere plasma was firstly accessed on the HL-3. The successful commissioning of HL-3 is beneficial for the initial operation of ITER.

1 MA plasma↗

Analysis of synthetic electron cyclotron emission from the high field side of HL-2M tokamak plasmas

A synthetic electron cyclotron emission (ECE) diagnostic is used to interpret ECE signals from preset plasma equilibrium profiles, including magnetic field, electron density, and electron temperature. According to the simulation results, the electron temperature (T e ) profile covering the harmonic overlap region can be obtained by receiving ECE signals at the high field side (HFS) of the HL-2M plasma. The third harmonic ECE at the low field side (LFS) cannot pass through the second harmonic resonance layer at the HFS unless the optical thickness (τ) of the second harmonic becomes gray (τ ≤ 2). In addition, the impact of the relativistic frequency down-shift has been evaluated and corrected. The measurable range of the HFS ECE has been calculated by scanning different parameters (electron density, temperature, and magnetic field). Higher plasma parameters allow a wider radial range of electron temperature measurements. The minimum inner measurable position can reach R = 120 cm (r/a = -0.89) when the product of core temperature (T e0 ) and density (n e0 ) is greater than 35 × 10 19 keV m -3 , which is extended by more than 30 cm inward compared with that of the LFS measurement. The HFS ECE will greatly improve the diagnostic ability of ECE systems on the HL-2M tokamak.

47 OTHER INSTRUMENTATION↗