Tooker, Angela C.

Publications and source records attributed to Tooker, Angela C..

At least 19 records

Spatiotemporal analysis of 3D human iPSC-derived neural networks using a 3D multi-electrode array

While there is a growing appreciation of three-dimensional (3D) neural tissues (i.e., hydrogel-based, organoids, and spheroids), shown to improve cellular health and network activity to mirror brain-like activity in vivo , functional assessment using current electrophysiology techniques (e.g., planar multi-electrode arrays or patch clamp) has been technically challenging and limited to surface measurements at the bottom or top of the 3D tissue. As next-generation MEAs, specifically 3D MEAs, are being developed to increase the spatial precision across all three dimensions (X, Y, Z), development of improved computational analytical tools to discern region-specific changes within the Z dimension of the 3D tissue is needed. In the present study, we introduce a novel computational analytical pipeline to analyze 3D neural network activity recorded from a “bottom-up” 3D MEA integrated with a 3D hydrogel-based tissue containing human iPSC-derived neurons and primary astrocytes. Over a period of ~6.5 weeks, we describe the development and maturation of 3D neural activity (i.e., features of spiking and bursting activity) within cross sections of the 3D tissue, based on the vertical position of the electrode on the 3D MEA probe, in addition to network activity (identified using synchrony analysis) within and between cross sections. Then, using the sequential addition of postsynaptic receptor antagonists, bicuculline (BIC), 2-amino-5-phosphonovaleric acid (AP-5), and 6-cyano-5-nitroquinoxaline-2,3-dione (CNQX), we demonstrate that networks within and between cross sections of the 3D hydrogel-based tissue show a preference for GABA and/or glutamate synaptic transmission, suggesting differences in the network composition throughout the neural tissue. The ability to monitor the functional dynamics of the entire 3D reconstructed neural tissue is a critical bottleneck; here we demonstrate a computational pipeline that can be implemented in studies to better interpret network activity within an engineered 3D neural tissue and have a better understanding of the modeled organ tissue.

3D culture↗

Implantable neuromodulation system for closed-loop stimulation and recording simultaneously at multiple brain sets

The present disclosure relates to a modular system for deep brain stimulation (DBS) and electrocorticography (ECoG). The system may have an implantable neuromodulator for generating electrical stimulation signals adapted to be applied to a desired region of a brain via an attached electrode array. An aggregator module may be used for collecting and aggregating electrical signals and transmitting the electrical signals to the neuromodulator. A control module may be used which is in communication with the aggregator module for controlling generation of the electrical signals and transmitting the electrical signals to the aggregator.

Pannu, Satinderpall S.↗

System and method for three-dimensional in vitro flexible microelectrode array

The present disclosure relates to a biocompatible, in vitro probe system. The probe system may have a substrate and a culture well supported on the substrate. The culture well defines a three-dimensional volume for containing in vitro cultures of electroactive cells. The probe system has at least one probe subsystem supported on the substrate. The probe subsystem has at least one probe having an array of electrodes, with the probe being disposed within the culture well for in vitro electrically communicating with the electroactive cells. The probe subsystem is adapted to be interfaced to an external instrumentation/recording device.

Soscia, David↗

Cylindrical microelectrode array for neural stimulation and recording

A cylindrical microelectrode array having an elongated cylindrical core, and a multilayer structure conformally folded around and affixed to the cylindrical core so as to extend between opposite ends of the core. The multilayer structure has integrated sections including an electrode section with electrodes exposed through electrically insulating layers, a connector section with conductive bond pads for interfacing with external electronics, and a cable section with conductive traces encapsulated in electrically insulating layers and which connect between the electrodes and their corresponding bond pads. The array may be fabricated using a planar multilayer structure having the electrode, connector, and cable sections, and conformally folding the multilayer structure around and affixing to the cylindrical core. The cable section in particular may be conformally coiled around and affixed to the cylindrical core so that the electrical conduits helically extend between the connector and electrode sections.

Shah, Kedar G.↗

Miniaturized, automated in-vitro tissue bioreactor

In one embodiment, a system includes a bioreactor coupled to a substrate. The bioreactor includes: a plurality of walls defining a reservoir; a plurality of fluidic channels in at least some of the walls; a fluidic inlet in fluidic communication with the reservoir via, the fluidic channels; a fluidic outlet in fluidic communication with the reservoir via the fluidic channels; and one or more sensors coupled to the reservoir, each sensor being configured to detect one or more of: environmental conditions in the reservoir; and physiological conditions of one or more cells optionally present in the reservoir. In another embodiment, a method includes delivering media to a reservoir of a bioreactor; delivering a plurality of cells to the reservoir, controlling a reservoir temperature and a reservoir gas composition; using one or more of the sensors to monitor environmental and physiological conditions; and reporting the environmental and/or physiological conditions.

42 ENGINEERING↗

Domestic Supply Chain of Medical Consumables Needed During COVID-19 Pandemic

This report is an assessment of the availability, demand, and production capability of medical consumables needed to combat the COVID-19 pandemic. We focus here on the ability of the supply chain to increase production to meet demand during peak pandemic conditions. In addition, we report on domestic production efforts and supply chain issues, as well as the propensity of other countries to limit export of needed medical supplies to the United States. In brief, the domestic supply chain and production capability vary greatly depending on the consumable. Some consumables, such as N95 masks or face shields, can likely be nearly fully supplied by domestic production, while other consumables, such as gloves or surgical masks, have little domestic production and thus will depend on imports to meet demand. The assessment pulls primarily from published news sources and company press releases. As such, the demand and production numbers are not precisely known, and some degree of uncertainty exists in them. The total production capability is also often difficult to ascertain from these reports especially as other industries have begun to supplement existing supply chains. In addition, local conditions (including company financial decisions, local public health issues, and political aspects) can vary throughout the pandemic which will affect future production. The report also pulls from estimates of demand and domestic production of some consumables compiled by the White House COVID-19 Supply Chain Taskforce (SCTF) presented by Rear Admiral John Polowczyk before a June 9, 2020 hearing of the Senate Homeland Security and Governmental Affairs Committee. These numbers, where applicable, are likely to be more accurate than those found in public news sources since they are more directly tied to private companies’ actual orders and actual production estimates, as opposed to publicly released estimates. Finally, we note that other issues with the supply chain, including the production of raw materials, increase demand due to industries that have not previously used PPE now using it, and increased domestic production from non-traditional suppliers, make complete picture of a rapidly changing supply chain difficult to obtain. This report attempts to produce an accurate image of the supply and estimated demand, as understood by the authors who are not experts in the medical supply chain.

42 ENGINEERING↗

Method for electrochemical roughening of thin film electrodes

The present invention relates to surface roughening methods and more particularly to a method for electrochemical roughening of thin film macro- and micro-electrodes. In one embodiment, an electrochemical etch template is formed comprising polymer particles adsorbed on a surface of a substrate to be roughened, followed by electrochemically etching of exposed regions of the substrate between the polymer particles in the electrochemical etch template so as to selectively roughen the surface of the substrate. In another embodiment, a surface of the electrode is immersed in either a adsorbing acidic solution, such as sulfuric acid, or a non-adsorbing acidic solution, such as perchloric acid, followed by electrochemically pulse etching the surface of the substrate at a narrow frequency range for adsorbing acidic solutions, or at a wide frequency range for non-adsorbing acidic solutions.

36 MATERIALS SCIENCE↗

A microfabricated, 3D-sharpened silicon shuttle for insertion of flexible electrode arrays through dura mater into brain

Electrode arrays for chronic implantation in the brain are a critical technology in both neuroscience and medicine. Recently, flexible, thin-film polymer electrode arrays have shown promise in facilitating stable, single-unit recordings spanning months in rats. While array flexibility enhances integration with neural tissue, it also requires removal of the dura mater, the tough membrane surrounding the brain, and temporary bracing to penetrate the brain parenchyma. Durotomy increases brain swelling, vascular damage, and surgical time. Insertion using a bracing shuttle results in additional vascular damage and brain compression, which increase with device diameter; while a higher-diameter shuttle will have a higher critical load and more likely penetrate dura, it will damage more brain parenchyma and vasculature. One way to penetrate the intact dura and limit tissue compression without increasing shuttle diameter is to reduce the force required for insertion by sharpening the shuttle tip. We describe a novel design and fabrication process to create silicon insertion shuttles that are sharp in three dimensions and can penetrate rat dura, for faster, easier, and less damaging implantation of polymer arrays. Sharpened profiles are obtained by reflowing patterned photoresist, then transferring its sloped profile to silicon with dry etches. We demonstrate that sharpened shuttles can reliably implant polymer probes through dura to yield high quality single unit and local field potential recordings for at least 95 days. On insertion directly through dura, tissue compression is minimal. Significance. This is the first demonstration of a rat dural-penetrating array for chronic recording. This device obviates the need for a durotomy, reducing surgical time and risk of damage to the blood-brain barrier. This is an improvement to state-of-the-art flexible polymer electrode arrays that facilitates their implantation, particularly in multi-site recording experiments. This sharpening process can also be integrated into silicon electrode array fabrication.

60 APPLIED LIFE SCIENCES↗

Depositing bulk or micro-scale electrodes

Thicker electrodes are provided on microelectronic device using thermo-compression bonding. A thin-film electrical conducting layer forms electrical conduits and bulk depositing provides an electrode layer on the thin-film electrical conducting layer. An insulating polymer layer encapsulates the electrically thin-film electrical conducting layer and the electrode layer. Some of the insulating layer is removed to expose the electrode layer.

36 MATERIALS SCIENCE↗

Electrochemical Roughening of Thin-Film Platinum Macro and Microelectrodes

This protocol demonstrates a method for electrochemical roughening of thin-film platinum electrodes without preferential dissolution at grain boundaries of the metal. Using this method, a crack free, thin-film macroelectrode surface with up to 40 times increase in active surface area was obtained. The roughening is easy to do in a standard electrochemical characterization laboratory and incudes the application of voltage pulses followed by extended application of a reductive voltage in a perchloric acid solution. The protocol includes the chemical and electrochemical preparation of both a macroscale (1.2 mm diameter) and microscale (20 µm diameter) platinum disc electrode surface, roughening the electrode surface and characterizing the effects of surface roughening on electrode active surface area. This electrochemical characterization includes cyclic voltammetry and impedance spectroscopy and is demonstrated for both the macroelectrodes and the microelectrodes. Finally, roughening increases electrode active surface area, decreases electrode impedance, increases platinum charge injection limits to those of titanium nitride electrodes of same geometry and improves substrates for adhesion of electrochemically deposited films.

42 ENGINEERING↗

System and method for neural interface with modular active electronics

A modular, high density electrical system is disclosed which makes use of an interface component, which is well suited to being placed in contact with an anatomy of either a human or an animal, and which may be releasably coupled to an electronics module subsystem. The interface component has a plurality of electrically conductive interconnect pads that may be releasably secured by a member to a plurality of electrically conductive pads of the electronics module subsystem. The electronics module subsystem may have a substrate which supports both an electronics circuit and the interconnect pads.

Shah, Kedar G.↗

Flexible neural interfaces with integrated stiffening shank

A neural interface includes a first dielectric material having at least one first opening for a first electrical conducting material, a first electrical conducting material in the first opening, and at least one first interconnection trace electrical conducting material connected to the first electrical conducting material. A stiffening shank material is located adjacent the first dielectric material, the first electrical conducting material, and the first interconnection trace electrical conducting material.

36 MATERIALS SCIENCE↗

Method to pattern <10 micrometer conducting and passivating features on 3D substrates for implantable devices

An implantable device has a cylindrical base, at least one electrode on the cylindrical base, at least one electrically conducting lead on the cylindrical base connected to the electrode wherein the electrically conducting lead has a feature size of <10 micrometers. A protective coating on the cylindrical base covers the at least one electrically conducting lead.

42 ENGINEERING↗

Vacuum-actuated percutaneous insertion/implantation tool for flexible neural probes and interfaces

A flexible device insertion tool including an elongated stiffener with one or more suction ports, and a vacuum connector for interfacing the stiffener to a vacuum source, for attaching the flexible device such as a flexible neural probe to the stiffener during insertion by a suction force exerted through the suction ports to, and to release the flexible device by removing the suction force.

42 ENGINEERING↗

Incorporating an optical waveguide into a neural interface

An optical waveguide integrated into a multielectrode array (MEA) neural interface includes a device body, at least one electrode in the device body, at least one electrically conducting lead coupled to the at least one electrode, at least one optical channel in the device body, and waveguide material in the at least one optical channel. The fabrication of a neural interface device includes the steps of providing a device body, providing at least one electrode in the device body, providing at least one electrically conducting lead coupled to the at least one electrode, providing at least one optical channel in the device body, and providing a waveguide material in the at least one optical channel.

42 ENGINEERING↗

Depositing bulk or micro-scale electrodes

Thicker electrodes are provided on microelectronic device using thermo-compression bonding. A thin-film electrical conducting layer forms electrical conduits and bulk depositing provides an electrode layer on the thin-film electrical conducting layer. An insulating polymer layer encapsulates the electrically thin-film electrical conducting layer and the electrode layer. Some of the insulating layer is removed to expose the electrode layer.

36 MATERIALS SCIENCE↗

Flexible neural interfaces with integrated stiffening shank

A neural interface includes a first dielectric material having at least one first opening for a first electrical conducting material, a first electrical conducting material in the first opening, and at least one first interconnection trace electrical conducting material connected to the first electrical conducting material. A stiffening shank material is located adjacent the first dielectric material, the first electrical conducting material, and the first interconnection trace electrical conducting material.

36 MATERIALS SCIENCE↗