Search NASA⌕ Search

Engineering topics

Tourbier, Dietmar

Publications and source records attributed to Tourbier, Dietmar.

Closing the Gap: A Global Perspective [Slides]

Against the backdrop of negotiations at COP26, a group of internationally recognised research and technology organisations launched a collaboration, with the intention to identify the national and international technology-led opportunities to decarbonise fossil fuel basins globally. This study will evidence the opportunities available to players across the entire energy ecosystem. Governments and funders will be able to spread costs and investment risk, energy companies will develop a greater understanding of the global transition and possible opportunities to develop pilot projects worldwide, and there will be greater incentive to the supply chain once they are aware of the global applicability of certain technologies and technology solutions. Through the analysis and comparison of national energy systems, a number of Net Zero Deployment Strategies and Technology Priorities have been identified, that are shaping the direction of the construction of net zero integrated energy systems globally. These have been considered to design Recommendations for International Collaboration to accelerate the global energy transition.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Compression under a mechanical counter pressure space suit glove

Background: Current gas-pressurized space suits are bulky stiff shells severely limiting astronaut function and capability. A mechanical counter pressure (MCP) space suit in the form of a tight elastic garment could dramatically improve extravehicular activity (EVA) dexterity, but also be advantageous in safety, cost, mass and volume. The purpose of this study was to verify that a prototype MCP glove exerts the design compression of 200 mmHg, a pressure similar to the current NASA EVA suit. Methods: Seven male subjects donned a pressure measurement array and MCP glove on the right hand, which was placed into a partial vacuum chamber. Average compression was recorded on the palm, the bottom of the middle finger, the top of the middle finger and the dorsum of the hand at pressures of 760 (ambient), 660 and 580 mmHg. The vacuum chamber was used to simulate the pressure difference between the low breathing pressure of the current NASA space suits (approximately 200 mmHg) and an unprotected hand in space. Results: At ambient conditions, the MCP glove compressed the dorsum of the hand at 203.5 +/- 22.7 mmHg, the bottom of the middle finger at 179.4 +/- 16.0 mmHg, and the top of the middle finger at 183.8 +/- 22.6 mmHg. The palm compression was significantly lower (59.6 +/- 18.8 mmHg, p<0.001). There was no significant change in glove compression with the chamber pressure reductions. Conclusions: The MCP glove compressed the dorsum of the hand and middle finger at the design pressure.

NASA Discipline Life Sciences Technologies↗

Skin microvascular flow during hypobaric exposure with and without a mechanical counter-pressure space suit glove

INTRODUCTION: Current space suits are rigid, gas-pressurized shells that protect astronauts from the vacuum of space. A tight elastic garment or mechanical-counter-pressure (MCP) suit generates pressure by compression and may have several advantages over current space suit technology. In this study, we investigated local microcirculatory effects produced with and without a prototype MCP glove. METHODS: The right hand of eight normal volunteers was studied at normal ambient pressure and during exposure to -50, -100 and -150 mm Hg with and without the MCP glove. Measurements included the pressure against the hand, skin microvascular flow, temperature on the dorsum of the hand, and middle finger girth. RESULTS: Without the glove, skin microvascular flow and finger girth significantly increased with negative pressure, and the skin temperature decreased compared with the control condition. The MCP glove generated approximately 200 mm Hg at the skin surface; all measured values remained at control levels during exposure to negative pressure. DISCUSSION: Without the glove, skin microvascular flow and finger girth increased with negative pressure, probably due to a blood shift toward the hand. The elastic compression of the material of the MCP glove generated pressure on the hand similar to that in current gas-pressurized space suit gloves. The MCP glove prevented the apparent blood shift and thus maintained baseline values of the measured variables despite exposure of the hand to negative pressure.

NASA Discipline Cardiopulmonary↗