Search NASA⌕ Search

Engineering topics

Tran, H.

Publications and source records attributed to Tran, H..

Multispectrum analysis of air-broadened spectra in the ν 3 Q branch of 12CH4

In this paper, we report experimental measurements of spectral line shape parameters (air-broadened width, shift, and line mixing coefficients) for several transitions in the ν 3 Q branch of methane in the 3000–3023 cm -1 region. 13 high-resolution, room temperature laboratory spectra of pure methane and air-broadened methane recorded with two different Fourier transform spectrometers are fitted. 12 of these spectra were acquired at 0.01 cm -1 resolution with the McMath-Pierce FTS at the National Solar Observatory on Kitt Peak, and one higher-resolution (~0.0011 cm-1) low pressure methane spectrum was obtained with the Bruker IFS-120HR FTS at the Pacific Northwest National Laboratory, in Richland, Washington. All the spectra were obtained using high purity natural samples of CH 4 and lean mixtures of the same natural CH 4 in dry air. For the 12 spectra recorded at Kitt Peak, three different absorption cells (L= 5, 25 and 150 cm) were used while the methane spectrum at PNNL was obtained using a 19.95 cm long absorption cell. For the analysis, an interactive multispectrum nonlinear least squares fitting software was employed where all the 13 spectra were fitted simultaneously. An accurate and self-consistent set of line parameters were determined by constraining a few of those for severely blended transitions. Line mixing was measured for fourteen transition pairs for the CH 4 -air collision system. Lastly, a constant speed dependence parameter, consistent with measured speed dependence values obtained in other methane bands, was applied to all the transitions included in the fitted region. The present measurements are compared to values reported in the literature.

12CH4↗

The HITRAN2016 molecular spectroscopic database

This paper describes the contents of the 2016 edition of the HITRAN molecular spectroscopic compilation. The new edition replaces the previous HITRAN edition of 2012 and its updates during the intervening years. The HITRAN molecular absorption compilation is comprised of five major components: the traditional line-by-line spectroscopic parameters required for high-resolution radiative-transfer codes, infrared absorption cross-sections for molecules not yet amenable to representation in a line-by-line form, collision-induced absorption data, aerosol indices of refraction, and general tables such as partition sums that apply globally to the data. The new HITRAN is greatly extended in terms of accuracy, spectral coverage, additional absorption phenomena, added line-shape formalisms, and validity. Moreover, molecules, isotopologues, and perturbing gases have been added that address the issues of atmospheres beyond the Earth. Of considerable note, experimental IR cross-sections for almost 200 additional significant molecules have been added to the database.

Gordon, I. E.↗

The first data release of the KODIAQ survey

We present and make publicly available the first data release (DR1) of the Keck Observatory Database of Ionized Absorption toward Quasars (KODIAQ) survey. The KODIAQ survey is aimed at studying galactic and circumgalactic gas in absorption at high redshift, with a focus on highly ionized gas traced by O vi, using the HIRES spectrograph on the Keck I telescope. KODIAQ DR1 consists of a fully reduced sample of 170 quasars at 0.29<z{sub em}<5.29 observed with HIRES at high resolution (36,000 ≤ R ≤ 103,000) between 2004 and 2012. DR1 contains 247 spectra available in continuum normalized form, representing a sum total exposure time of ∼1.6 megaseconds. These coadded spectra arise from a total of 567 individual exposures of quasars taken from the Keck Observatory Archive (KOA) in raw form and uniformly processed using a publicly available HIRES data reduction package. DR1 is publicly available to the community, housed as a higher level science product at the KOA. We will provide future data releases that make available additional quasars, including those with pre-2004 observations taken with the previous-generation HIRES detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of Ionizing Radiation Doses Induced by High Irradiance Laser on Targets in LCLS MEC Instrument - Paper 75

High-power laser interaction with targets in vacuum at high laser irradiance levels can generate plasma and, consequently, create ionizing radiation hazards. The theory for ionizing radiation generation from laser-plasma interaction is complicated. The basics of theory and phenomenology are available qualitatively. However, the ionizing radiation yields associated with laser-plasma interaction have not been well quantified. Based on the theoretical analysis and review of the published reports and measurement data, SLAC National Accelerator Laboratory (SLAC) developed an analytic model to estimate conservatively the electron temperature and photon radiation yield (Sv/J) of a laser pulse hitting a solid target at 1 m as a function of laser irradiance between 10{sup 15} and 10{sup 21} W/cm{sup 2}. Ionizing radiation measurements from high-intensity laser-induced plasma interactions on solid targets inside the Al-walled vacuum chamber of the LCLS MEC instrument at SLAC were conducted using passive and active detectors at irradiance between 3x10{sup 16} and 6x10{sup 17} W/cm{sup 2}. Each run of the more than 20 runs had a unique set of laser, optic and target conditions with laser pulses rastering over the target surface mainly perpendicularly at a fixed irradiance. Significant effort was made in characterizing the laser irradiance values for each configuration of laser, focusing mirror, and target; four irradiances with targets of Au foils and copper plate were found to produce good measurement results. Electron doses inside the target chamber were highly anisotropic and peaked at backward direction by several orders of magnitude. Photon doses outside the target chamber were nearly isotropic (a factor of ∼2 higher in backward direction). When considering the large uncertainties of the irradiance (a factor of 2-3) and the potential shielding effects from detectors and target chamber, the measured photon dose rates at 1 m (150 mJ and 10 Hz) outside the target chamber (when averaged over different types of detectors) were in good agreement (a factor of ∼3) with the calculated values of the SLAC model, except at 3.0x10{sup 16} W/cm{sup 2}, which has an electron temperature of only 14 keV. At 6x10{sup 17} W/cm{sup 2}, a low level of ∼0.1 mrem/h from fast neutrons was measured (at 1 m, 150 mJ and 10 Hz) with a neutron-to-photon dose ratio of 0.2%. This is equivalent to a neutron dose yield of 2.8x10{sup -8} mSv/J (to be compared to the LULI measurements of 1x10{sup -4} mSv/J at 3x10{sup 19} W/cm{sup 2}). Both active and passive types of detectors performed well and the dose results were consistent, which is the same as the dose measurements in the Titan laser facility. Active detectors were not affected by the electromagnetic pulses associated with the MEC laser system; this was different from the Titan radiation measurements, in which all active detectors failed to respond, likely due to the high EMP in the Titan's high laser intensity fields. (authors)

43 PARTICLE ACCELERATORS↗

Measurements of Ionizing Radiation Doses Induced by High Irradiance Laser on Targets in LCLS MEC Instrument

Comprehensive measurements for photon and neutron radiation doses generated from laser-plasma interaction at SLAC’s MEC laser facility have been conducted. The goals of the measurements were to; determine the radiation dose per laser shot as a function of laser, optic and target parameters that are relevant to the MEC laser operations; validate the RPD-developed analytic model for photon dose calculations; and evaluate the performance of various types of passive and active detectors in the laser-induced radiation fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗