Effect of continuously flowing liquid Li limiter on particle and heat fluxes during H-mode discharges in EAST
Not Available
Engineering topics
Publications and source records attributed to Tritz, K..
Not Available
For this study, a lithium (Li) vapour layer was formed around a flowing liquid Li limiter to shield against the plasma incident power and reduce limiter heat flux in the EAST tokamak. The results revealed that after a plasma operation of a few seconds, the layer became clear, which indicated a strong Li emission with a decrease in the limiter surface temperature. This emission resulted in a dense vapour around the limiter, and Li ions moved along the magnetic field to form a green shielding layer on the limiter. The plasma heat flux loaded on the limiter, measured by the probe installed on the limiter, was approximately 52% lower than that detected by a fast-reciprocating probe at the same radial position without the limiter in EAST. Additionally, approximately 42% of the parallel heat flux was dissipated directly with the enhanced Li radiation in the discharge with the liquid metal infused trenches (LIMIT) limiter. This observation revealed that the Li vapour layer exhibited an excellent shielding effect to liquid Li on plasma heat flux, which is a possible benefit of liquid-plasma-facing components in future fusion devices.
Here, in this study, the corrosion behaviours of molybdenum (Mo) and a Mo-based alloy (TZM) were investigated using a static immersion corrosion technique. Weight loss, surface microstructure, and corrosion depth of Mo and the TZM alloy were correlated with elements. The compatibility of Mo and the TZM alloy in static liquid Li was suitable. Mo demonstrated uniform corrosion with a homogenous dissolution of free C and Mo, and TZM alloy exhibited a nonuniform corrosion behaviour with a preferential grain boundary attack caused by the selective dissolution of free C, Ti, and Zr. When the surface oxidation layer of the samples was consumed, free C from Mo and TZM diffused into molten Li to form Li 2 C 2 and then was captured by Zr, Ti, and Mo to form thermodynamically stable carbides, which resulted in the enrichment of the C layer near the sample surfaces. In addition, Ti and Zr acted as N-trappers in liquid Li; the formation of Zr and Ti nitrides resulted in the enrichment of N, Ti, and Zr elements on the surface and led to TZM corrosion increase. Thus, Zr and Ti depletion, pitting, and grain boundary corrosion were problematic for TZM under long-term exposure to liquid Li. Reducing the content of free C and nonmetallic N and increasing the amount of Ti and Zr carbides on the surface of and inside the raw TZM alloy helped improve the corrosion resistance of TZM in liquid Li.
A reproducible, quasi-stationary edge localized mode (ELM)-suppressed scenario was obtained over a wide range of plasma parameters by continuous injection of boron (B) powder into an upper-single null discharge in the experimental advanced superconducting tokamak [Sun et al., Nucl. Fusion 61, 014002 (2021)]. This powder-induced ELM-absent regime is associated with an edge harmonic mode (EHM) that provides continuous particle exhaust to maintain constant density without confinement degradation and impurity accumulation, the latter of which is often observed in ELM-free regimes. A flow rate threshold of B powder injection, leading to a threshold intensity of the EHM, is necessary for full ELM suppression. The fundamental harmonic of the EHM exhibits a toroidal mode number n = 1. The mode is observable in the entire poloidal cross section with a peak near the upper X-point in an upper-single null configuration. Here, the EHM spans radially across the pedestal and scrape-off layer, peaking inside the separatrix. The EHM appears to be insensitive to q 95 , heating power, plasma toroidal rotation, and pedestal collisionality.
Large edge-localized modes (ELMs) were mitigated by gravitational injection of lithium granules into the upper X-point region of the experimental advanced superconducting tokamak (EAST) device with tungsten plasma-facing components. The maximum ELM size was reduced by ~70% in high β N H-mode plasmas. Large ELM stabilization was sustained for up to about 40 energy confinement times, with constant core radiated power and no evidence of high-Z or low-Z impurity accumulation. The lithium granules injection reduced the edge plasma pedestal density and temperature and their gradients, due to increased edge radiation and reduced recycling from the plasma-facing components. Ideal stability calculations using the ELITE code indicate that the stabilization of large ELMs correlates with improved stability of intermediate-n peeling-ballooning modes, due to reduced edge current resulting from the profile changes. The pedestal pressure reduction was partially offset by a core density increase, which resulted in a modest ~7% drop in core stored energy and normalized energy confinement time. We surmise that the remnant small ELMs are triggered by the penetration of multiple Li granules just past the separatrix, similar to small ELMs triggered by deuterium pellet Futatani et al (2014 Nucl. Fusion 54 073008). This study extends previous ELM elimination with Li powder injection Maingi et al (2018 Nucl. Fusion 58 024003) in EAST because (1) use of small, dust-like powder and the related potential health hazards were eliminated, and (2) use of macroscopic granules should be more applicable to future devices, due to deeper penetration than dust particles, e.g. inside the separatrix with velocities ~10 m s -1 in EAST.
We report an observation of robust suppression of edge-localized modes (ELMs) in the Experimental Advanced Superconducting Tokamak (EAST), enabled by continuous boron (B) powder injection. Edge harmonic oscillations appear during B powder injection, providing sufficient particle transport to maintain constant density and avoid impurity accumulation in ELM-stable plasmas. Here, quasi-steady ELM suppression discharges are demonstrated with modest energy confinement improvement and over a wide range of conditions: heating power and technique variation, electron density range over a factor ~3.5, deuterium or helium ion species, and with either direction of the toroidal magnetic field. ELM suppression is observed above a threshold edge B intensity and ceases within 0.5 s of termination of the B injection. In contrast to ELM suppression accompanied by recycling reduction during Li powder injection in NSTX and EAST (Maingi et al 2018 Nucl. Fusion 58 024003), reduced recycling due to hydrogenic species retention is unnecessary for the ELM suppression with B powder injection, paving the way for its consideration as an ELM control tool for future fusion devices.
Lithium (Li) is a promising low-Z material for particle recycling and impurity control to improve plasma performance in fusion devices. In the experimental advanced superconducting tokamak (EAST), Li coating has become a routine method for wall conditioning, and a flowing liquid Li (FLiLi) limiter has been successfully tested several times. Deuterium retention characteristics in the Li film coated on the international thermonuclear experimental reactor-like tungsten divertor and FLiLi during plasma discharges, which is important for the utilization of Li in future fusion devices, were investigated in EAST. It is found that the absorption of the fuel particles by Li coatings decreases gradually, and recycling gradually increases over a series of discharges. The maximum net amount of deuterium retained reached ~0.8 g, corresponding to 12% deuterium in the Li. Furthermore, this corresponds to a whole day's worth of shots with a total of 87 plasma discharges and a total of ~640s plasma time after 11.75 g Li was deposited. Compared to the Li coating, it is shown that FLiLi continuously traps fuel particles and achieves a higher deuterium retention ratio over both the short- and long-term, leading to lower recycling. Meanwhile, it is also observed that the fuel particle retention ratio increases when FLiLi is closer to the plasma. This result is likely due to higher plasma heating power and limiter temperature, which cause an increased Li efflux from FLiLi due to a higher limiter temperature, which then redeposits on the other plasma-facing surfaces and increases fuel particle absorption. It is estimated that ≥ 80% of the retained D particles are captured by the continual renewal of the Li redeposition film during the FLiLi operation. This investigation would also be useful for D/T retention in future fusion devices if Li is used as a plasma-facing component.
To study the potential applications of liquid lithium (Li) as plasma facing material, the third generation of flowing liquid Li (FLiLi) limiter has been designed and successfully tested in EAST tokamak H-mode discharges in the 2018 run campaign. Here, the stability of liquid Li on FLiLi surface, and Li splashing and its effect on the plasma performance are investigated in detail. Li splashing was observed in L-mode and H-mode discharges due to Rayleigh-Taylor (R-T) instability, resulting from electromagnetic forces J → x B → . Li splashing in low-parameter plasma decreased both core and edge electron temperatures, resulting in the degradation of plasma energy confinement and even H-L back transition, however, it almost did not influence plasma confinement performance in high-parameter plasma. These findings indicate that high-parameter plasma has higher tolerance to Li impurities than low-parameter plasma. By contrast, tungsten splashing from the melted layer on the upper divertor was also induced by the R-T instability but generally resulted in plasma disruption, which suggests lower tolerance to tungsten impurities in EAST tokamak.
Type I edge-localized modes (ELMs) in the Experimental Advanced Superconducting Tokamak (EAST) were completely suppressed via boron powder injection into the X-point region of an upper-single null configuration over a wide range of operating conditions (2.8 < P aux < 7.5 MW, 3.8 × 10 19 < n e < 6 × 10 19 m -3 , RF-only and RF + NBI heating scenarios, both grad-B drift directions, and even He ion majority plasmas) (Sun et al. in Nucl. Fusion, 2020). A window of edge B concentration for stable long pulse operation was identified: too low and ELMs return, too high and the discharge suffers radiative collapse. The injection of boron powder above the minimum for ELM suppression coincided with the occurrence of an edge harmonic oscillation detected in magnetics (both on the high-field side and low-field side), in AXUV diodes near the upper X-point, divertor Dα emission, and in a range of other diagnostics (Diallo et al. in: Proceedings of 2020 IAEA fusion energy conference, 2021). Furthermore, no harmonic oscillation was observed when ELMs were present, and stored energy was slightly increased at constant density during ELM suppression. Core tungsten emission during ELM suppression either increased or decreased relative to ELMy H-mode, but the W emission was maintained at acceptable levels. The threshold B injection rate was measured for several conditions, and found to increase with heating power. Li powder injection into comparable discharges also resulted in a short phase of ELM suppression, but density and stored energy both decreased due to the strong pumping effect of lithium; no edge harmonic oscillation was observed with Li injection, indicating that the ELM suppression mechanisms differ. The new set of B-seeded, ELM-suppressed discharges exhibited certain characteristics of quiescent H-mode (Burrell et al. in Phys Plasmas 8:2153, 2001), but did not require high shear, counter beams, etc. The wide operating window and compatibility with RF-only discharges paves the way for future experiments targeting long pulse H-mode discharges with complete ELM suppression.
A third generation flowing liquid lithium (FLiLi) limiter with a substrate made of TZM, an alloy with >99% Mo, was fabricated by conventional manufacturing techniques. TZM has a high corrosion resistance, a high sputtering threshold, and a good wettability to Li, as compared to stainless steel (SS), which had been used as an FLiLi substrate surface in 2014 and 2016. The third generation FLiLi was inserted into the edge in EAST H-mode plasmas in an upper single-null configuration with an ion grad-B drift toward the upper divertor with a limiter temperature of 330–380 °C and an auxiliary heating power of about 2–8 MW. Analysis has shown that by using TZM FLiLi, fuel particle recycling continuously decreased and near-complete edge localized mode elimination was achieved in H-mode plasmas with RF-only heating. The main impurities during the initial FLiLi discharges were Mo, Fe, and W resulting from strong plasma interaction at the Mo plate side, the SS collector, and the upper W divertor. Plasma stored energy increased by about 10 kJ in subsequent FLiLi discharges due to decreased impurity radiation. Engineering analysis shows a uniform lithium flow with an ~80% Li coverage ratio on the limiter surface, similar to the second FLiLi, even though only one of two J × B pumps was functioning. Despite technical difficulties, the FLiLi gen.3 improved the overall plasma performance, providing support for flowing liquid Li plasma facing component applications in present and future devices.
A multi-institutional team consisting of national labs and universities has been conducting research to understand and control the plasma-material interface (PMI) to improve long pulse discharge control and performance in the EAST device in Hefei, China. One particular focus of the group has been to evaluate the performance of different plasma-facing component (PFC) technologies and materials, particularly lithium. Flowing liquid lithium PFC technologies are currently into their third generation of development and deployment in EAST, demonstrating recycling control and mitigation of edge-localized modes (ELMs). A lithium powder dropper has also been used to control ELMs while a lithium granule injector has demonstrated ELM triggering and pacing. To support this work, the facilities at the Center for Plasma Material Interactions such as HIDRA are being commissioned and utilized to develop/test the technologies before deployment on EAST. This paper will present a summary of the collaborative lithium PMI program on EAST.
Three generation of flowing liquid lithium (FLiLi) limiters have been developed and successfully tested in EAST since 2014. It was confirmed that liquid Li could be driven by an innovative in-vessel DC electromagnetic J × B pump to form a recirculating loop. The FLiLi design was continuously upgraded, resulting in improvement of the liquid Li surface coverage (>80%), elimination of surface erosion, and the increase of heat exhaust capability. Promising results are obtained during FLiLi operations, including a reduction of impurities and recycling to improve plasma confinement, and a mitigation of ELM activity in H-mode plasmas. The FLiLi limiter program has shown basic compatibility with H-mode discharges with auxiliary heating power up to 8.3 MW. These efforts will expand to flowing liquid Li PFC in high heat flux zones, e.g. near the divertor strike point in reactors.
A novel continuously flowing liquid lithium limiter (FLiLi) which employs an in-vessel electro-magnetic pump to drive liquid Li flowing on the surface of limiter has been successfully designed and tested in the experimental advanced superconducting tokamak (EAST) device in 2014. In order to better control the surface temperature, an upgraded design and the real-time gas cooling were performed in 2016. Two kinds of cooling gas, helium (He) and argon (Ar) were tested on the FLiLi system prior to the experiment. It was found that the cooling rates of He and Ar at 2.5 MPa are 34.2 °C/min, 10.2 °C/min or 31.7 °C/kL and 28.1 °C/kL, respectively. The cooling performance of He is more effective than Ar. Experimental results show that the real-time He cooling could effectively contain the FLiLi surface temperature increase and prevent the strong passive evaporation of lithium during plasma discharges. Limiter heat flux up to 0.2 MW/m2 was removed during ohmic discharge with 2.5 MPa He gas. Finally, Because of the upgraded design and real-time gas cooling, the surface of FLiLi was not damaged by heat flux after entire plasma discharge.