Studies of Helium Behavior in Uranium Hexafluoride

Several issues have arisen from experimental observations and/or theoretical postulation related to the behavior of helium in uranium hexafluoride (UF 6 ) matrices and how it may impact the ability to use this noble gas to quantify the fill date of the cylinder. A series of experiments was conducted to address several such issues, and the results and implications are reported here. Two issues relate to bias in the helium measurement due to ambient air from extraneous sources such as atmospheric air or from potential holdup in a large, activated alumina chemical trap. These issues are really a question of differential retention of helium versus three other inert gas isotopes (representative of other noble gases found in air) used as a calibration for air in leakage. Discernable bias was not detected in either case. Another issue had to do with helium potentially brought into the cylinder by a liquid UF 6 fill and subsequently released as the material solidifies and/or during storage. The solubility of helium in liquid UF 6 was measured to investigate this theory. The experiment quantified the potential magnitude of the initial helium contribution if present. The final issue was that of retention of helium in solid UF 6 . Investigation of this theory necessitated quantifying both the solubility and the diffusivity of helium in UF 6 . In one experiment, the solubility was measured at cryogenic temperature, allowing quantification of helium in solid UF 6 such as would be found in a cold trap. In a second experiment, transport of helium into and through a macroscopic plug of solid UF 6 was examined. The transport was very slight although apparently detectible. Effectively, only an upper limit to the transport could be determined, but that limit implied that helium holdup in solid UF 6 is a real possibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct uranium enrichment assay in gaseous uranium hexafluoride with laser induced breakdown spectroscopy

A set of eleven U atomic emission lines, between 421.099 and 421.460 nm, were characterized for direct enrichment assay of gaseous UF 6 samples with laser induced breakdown spectroscopy (LIBS). Several iterative, multivariate nonlinear spectral-fitting algorithms were evaluated for their efficacies to extract the enrichment information from the measured LIBS spectra. Furthermore, wavelength-dependent weight factors, which take into consideration of the spectral-line position in the fitting model, the determined isotopic ratio, and the isotopic shift of the emission line, are essential for the spectral-fitting model to function adequately. The analytical accuracies and precision were typically within 0.5% in absolute [ 235 U/( 235 U + 238 U)] ratios.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analytical characterization of laser induced plasmas towards uranium isotopic analysis in gaseous uranium hexafluoride

To perform direct enrichment assay on gaseous uranium hexafluoride (UF 6 ) with laser induced breakdown spectroscopy (LIBS), the dominant spectral-line features, evolution of the signal and background of the U II 424.437 nm line, and its Stark width and shift, were studied as a function of UF 6 gas pressure and pulse energy of a nanosecond Nd:YAG laser. In this work, vapor pressure of UF 6 was found to be the most important parameter for LIBS analysis of gaseous UF 6 . Spectral congestion with numerous U lines of high excitation potential was observed and signal-to-background ratio (SBR) was low for measurements with 80 Torr UF 6 . Only when both UF 6 vapor pressure and laser pulse energy were low, for example, less than 20 Torr pressure and 30 mJ pulse energy, the resultant LIBS spectra from gaseous UF 6 resembled those obtained from solid U samples. The experimental data also suggest that U and F atoms recombine back to UF 6 after the laser pulse. The U emission was found to decay fast with a persistent background signal, degrading SBR with delay time. Systematic positive biases were found for UF 6 enrichment assays performed with the 235 U– 238 U line pair at 424.412–424.437 nm, which was confirmed to be caused by self-absorption. Even with optimization of experimental parameters and incorporation of a self-absorption term into the spectral-fitting algorithm, to reduce and compensate for self-absorption, self-absorption is still a main factor limiting accurate UF 6 enrichment assay. The use of another spectral window which contains no resonance lines is a prospective solution for the self-absorption issue.