Search NASA⌕ Search

Engineering topics

Trujillo, Christopher J.

Publications and source records attributed to Trujillo, Christopher J..

LANL studies of ESD spark energy discharge through September 2019

Two concentric-sphere apparatuses were used to measure the energies deposited by electric sparks through air to calibrated loads. Both sets of spheres had clean, uninsulated metal surfaces. The 127-mm diameter pair of spheres had a gap of 10 mm and a capacitance of 52 pF. The maximum energy stored on these spheres was 12 mJ and the maximum energy delivered to the 50-mΩ load was 11 µJ, with or without inductance. This load energy amounted to 0.09% of the available input energy; the remainder of the input energy was expended in forming the spark. The second set of spheres was 330 mm in diameter with a gap of 14 mm and a capacitance of 240 pF. The maximum energy stored on these spheres was 71 mJ and the maximum energy delivered to the 50-mΩ load was 150 µJ without added inductance. This load energy was 0.27% of the input energy; again, the remainder of the input energy was expended in forming the spark. The inclusion of 250 nH and 500 nH inductances in the discharge path of the smaller spheres caused the current discharges to resonate, but had little effect on the maximum energies deposited in the loads. At the time of writing, inductances had not yet been added to the larger spheres. The magnitudes of the observed spark discharges were stochastic, so more than 1200 tests were required to develop the statistical bounds of the spark behavior, i.e., to estimate the worst case (highest likely) energy depositions in the loads. The action integrals of the current discharges $∫ i^2dt$ were found to be approximately independent of the load resistances for loads of less than ~1 Ω. Hence the energy deposition scaled with resistance as 207 µJ/Ω and 2.93 mJ/Ω for the two apparatuses.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Rogowski Coils For Studies Of Detonator Initiation And Other Diagnostics

Detonators are fundamental to most explosive systems, yet the detonators themselves are rarely diagnosed to determine how well they function or why they fail. To remedy this, various electrical diagnostics were explored, including: Rogowski coils for high fidelity detection of changes in electrical current in explosive bridgewires and how they relate to detonator performance; and radio frequency (RF) antennas to detect any electromagnetic emissions associated with reaction and growth in the explosives. A new type of Rogowski coil is described and some interesting phenomena were detected with the radio frequency antenna.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing detonator performance through radio wave emissions

Experiments were performed using a copper antenna to observe transient electric fields generated by shocked Pentaerythritol Tetranitrate (PETN), which behaves as a piezoelectric explosive. PETN pellets were shocked using a detonator and polyvinyl chloride (PVC) as shock attenuation. The amount of attenuation was varied until an initiation threshold was found to increase the probability of a deflagration-to-detonation (DDT) transition occurring. These experiments showed distinct transient shifts in frequency over the duration of the experiments. Correlation was observed between certain shifts in frequency and if the PETN pellet detonated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Novel uses of detonator diagnostics

A novel combination of diagnostics is being used to research the physics of detonator initiation. The explosive PETN (Pentaerythritol tetranitrate) commonly used in detonators, is also a piezo-electric material that, when sufficiently shocked, emits an electromagnetic field in the radio frequency (RF) range, along crystal fracture planes. In an effort to capture this RF signal, a new diagnostic was created. A copper foil, used as an RF antenna, was wrapped around a foam fixture encompassing a PETN pellet. Rogowski coils were used to obtain the change in current with respect to time (di/dt) the detonator circuit, in and polyvinylidene difluoride (PVDF) stress sensors were used to capture shockwave arrival time. The goal of these experiments is to use these diagnostics to study the reaction response of a PETN pellet of known particle size to shock loading with various diagnostics including an antenna to capture RF emissions. Our hypothesis is that RF feedback may signify the rate of deflagration to detonation transition (DDT) or lack thereof. The new diagnostics and methods will be used to determine the timing of start of current, bridge burst, detonator breakout timing and RF generated from detonation. These data will be compared to those of currently used diagnostics in order to validate the accuracy of these new methods. Future experiments will incorporate other methods of validation including dynamic radiography, optical initiation and use of magnetic field sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A thesis on the Development of an Automated SWIFT Edge Detection Algorithm

Throughout the world, scientists and engineers such as those at Los Alamos National Laboratory, perform research and testing unique only to applications aimed towards advancing technology, and understanding the nature of materials. With this testing, comes a need for advanced methods of data acquisition and most importantly, a means of analyzing and extracting the necessary information from such acquired data. In this thesis, I aim to produce an automated method implementing advanced image processing techniques and tools to analyze SWIFT image datasets for Detonator Technology at Los Alamos National Laboratory. Such an effective method for edge detection and point extraction can prove to be advantageous in analyzing such unique datasets and provide for consistency in producing results.

97 MATHEMATICS AND COMPUTING↗