Truong, Gar-Wing

Publications and source records attributed to Truong, Gar-Wing.

Frequency Comb-Based Remote Methane Observation Network (Final Scientific/Technical Report)

ARPA-E investment in long-range, frequency comb-based methane detection has resulted in the first scalable, cost-effective continuous methane emissions system. At the onset of this ARPA-E MONITOR award, the dual-frequency comb spectrometer was a sprawling, expensive, laboratory-confined device which had only recently been demonstrated capable of measuring atmospheric trace gases over open-paths. Bringing the technology to the point of being able to monitor for and characterize methane emissions at oil and natural gas production facilities seemed an almost impossible task. Over the subsequent months and years, our team transitioned the Nobel-prize-winning frequency-comb-laser spectrometer technology to a field-deployed regional methane leak detection system. The spectrometer enables highly sensitive near-infrared absorption measurements of methane along kilometer-scale laser beam paths. The measurements are coupled with an atmospheric modeling and inversion framework to triangulate the location of emission sources and quantify the emission rates.

03 NATURAL GAS↗

Intercomparison of open-path trace gas measurements with two dual-frequency-comb spectrometers

Abstract. We present the first quantitative intercomparison between two open-path dual-comb spectroscopy (DCS) instruments which were operated across adjacent 2 km open-air paths over a 2-week period. We used DCS to measure the atmospheric absorption spectrum in the near infrared from 6023 to 6376 cm−1 (1568 to 1660 nm), corresponding to a 355 cm−1 bandwidth, at 0.0067 cm−1 sample spacing. The measured absorption spectra agree with each other to within 5 × 10−4 in absorbance without any external calibration of either instrument. The absorption spectra are fit to retrieve path-integrated concentrations for carbon dioxide (CO2), methane (CH4), water (H2O), and deuterated water (HDO). The retrieved dry mole fractions agree to 0.14 % (0.57 ppm) for CO2, 0.35 % (7 ppb) for CH4, and 0.40 % (36 ppm) for H2O at ∼ 30 s integration time over the 2-week measurement campaign, which included 24 °C outdoor temperature variations and periods of strong atmospheric turbulence. This agreement is at least an order of magnitude better than conventional active-source open-path instrument intercomparisons and is particularly relevant to future regional flux measurements as it allows accurate comparisons of open-path DCS data across locations and time. We additionally compare the open-path DCS retrievals to a World Meteorological Organization (WMO)-calibrated cavity ring-down point sensor located along the path with good agreement. Short-term and long-term differences between the open-path DCS and point sensor are attributed, respectively, to spatial sampling discrepancies and to inaccuracies in the current spectral database used to fit the DCS data. Finally, the 2-week measurement campaign yields diurnal cycles of CO2 and CH4 that are consistent with the presence of local sources of CO2 and absence of local sources of CH4.

Waxman, Eleanor M.↗

Quantitative atomic spectroscopy for primary thermometry

Quantitative spectroscopy has been used to measure accurately the Doppler broadening of atomic transitions in {sup 85}Rb vapor. By using a conventional platinum resistance thermometer and the Doppler thermometry technique, we were able to determine k{sub B} with a relative uncertainty of 4.1x10{sup -4} and with a deviation of 2.7x10{sup -4} from the expected value. Our experiment, using an effusive vapor, departs significantly from other Doppler-broadened thermometry (DBT) techniques, which rely on weakly absorbing molecules in a diffusive regime. In these circumstances, very different systematic effects such as magnetic sensitivity and optical pumping are dominant. Using the model developed recently by Stace and Luiten, we estimate the perturbation due to optical pumping of the measured k{sub B} value was less than 4x10{sup -6}. The effects of optical pumping on atomic and molecular DBT experiments is mapped over a wide range of beam size and saturation intensity, indicating possible avenues for improvement. We also compare the line-broadening mechanisms, windows of operation and detection limits of some recent DBT experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗