Search NASA⌕ Search

Engineering topics

Tsou, J. J.

Publications and source records attributed to Tsou, J. J..

Results from the 1995 Stratospheric Ozone Profile Intercomparison at Mauna Loa (MLO3)

In August 1995 multiple instruments that measure the stratospheric ozone vertical distribution were intercompared at the Mauna Loa Observatory, Hawaii, under the auspices of the Network for the Detection of Stratospheric Change. The instruments included two UV lidar systems, one from JPL and the other from Goddard Space Flight Center, ECC balloon-sondes, a ground-based microwave instrument, Umkehr measurements, and a new ground-based FTIR instrument. The MLS instrument on the UARS satellite provided correlative profiles of ozone, and there was one close overpass of the SAGE II instrument. The results show that much better consistency among instruments is being achieved than even a few years ago, usually to within the instrument uncertainties. The different measurement techniques in this comparison agree to within +/-10% at almost all altitudes, and in the 20 km to 45 km region most agreed within +/-5%. The results show that the current generation of lidars are capable of accurate measurement of the ozone profile to a maximum altitude of 50 km. SAGE agreed well with both lidar and balloon-sonde down to at least 17 km. The ground-based microwave measurement agreed with other measurements from 22 km to above 50 km. One minor source of disagreement continues to be the pressure-altitude conversion needed to compare a measurement of ozone density versus altitude with a measurement of ozone mixing ratio versus pressure.

McPeters, R. D.↗

Stratospheric Ozone Intercomparison Campaign (STOIC) 1989: Overview

The NASA Upper Atmosphere Research Program organized a Stratospheric Ozone Intercomparison Campaign (STOIC) held in July-August 1989 at the Table Mountain Facility (TMF) of the Jet Propulsion Laboratory (JPL). The primary instruments participating in this campaign were several that had been developed by NASA for the Network for the Detection of Stratospheric Change: the JPL ozone lidar at TMF, the Goddard Space Flight Center trailer-mounted ozone lidar which was moved to TMF for this comparison, and the Millitech/LaRC microwave radiometer. To assess the performance of these new instruments, a validation/intercomparison campaign was undertaken using established techniques: balloon ozonesondes launched by personnel from the Wallops Flight Facility and from NOAA Geophysical Monitoring for Climate Change (GMCC) (now Climate Monitoring and Diagnostics Laboratory), a NOAA GMCC Dobson spectrophotometer, and a Brewer spectrometer from the Atmospheric Environment Service of Canada, both being used for column as well as Umkehr profile retrievals. All of these instruments were located at TMF and measurements were made as close together in time as possible to minimize atmospheric variability as a factor in the comparisons. Daytime rocket measurements of ozone were made by Wallops Flight Facility personnel using ROCOZ-A instruments launched from San Nicholas Island. The entire campaign was conducted as a blind intercomparison, with the investigators not seeing each others data until all data had been submitted to a referee and archived at the end of the 2-week period (July 20 to August 2, 1989). Satellite data were also obtained from the Stratospheric Aerosol and Gas Experiment (SAGE 2) aboard the Earth Radiation Budget Satellite and the Total Ozone Mapping Spectrometer (TOMS) aboard Nimbus 7. An examination of the data has found excellent agreement among the techniques, especially in the 20- to 40-km range. As expected, there was little atmospheric variability during the intercomparison, allowing for detailed statistical comparisons at a high level of precision. This overview paper summarizes the campaign and provides a 'road map' to subsequent papers in this issue by the individual instrument teams which will present more detailed analysis of the data and conclusions.

Margitan, J. J.↗

Ground-based microwave monitoring of middle atmosphere ozone: Comparison to lidar and Stratospheric and Gas Experiment 2 satellite observations

A dedicated ground-based microwave radiometer was in operation to monitor the middle atmospheric ozone concentration at Table Mountain Facility (TMF) of the Jet Propulsion Laboratory (JPL), California (34.4 deg N, 117.7 deg W) from July 1989 to June 1992, as a part of the Network for Detection of Stratospheric Change. Ozone profiles from 56 to 0.04 mbar (approximately 20 - 70 km) were retrieved from the microwave data. The focus in this paper is to validate the microwave ozone observations from 56 to 1 mbar by comparing the results from a JPL ground-based lidar located at the same site and from the Stratospheric Aerosol and Gas Experiment 2 (SAGE 2) satellite overpasses within 1000 km of TMF and to examine the ability of these instruments to detect short-term, seasonal, and annual variations in ozone. The profile comparison results show that the mean differences of microwave ozone from lidar and SAGE 2 are about 5% or less and the root-mean-square scatter about the mean is mainly from the precision of the instruments. A correlation analysis of ozone time series suggests highly significant correlations up to 2.4 mbar between lidar and microwave measurements and up to 1 mbar between SAGE 2 and microwave. The short-term and seasonal variation of the ozone profile seen in the microwave measurements is shown to be consistent with the observations of lidar and SAGE 2, and the interannual variation of ozone appears to be detectable within an accuracy of a few percent with the microwave instrument.

Tsou, J. J.↗

Ground-based microwave observations of ozone in the upper stratosphere and mesosphere

A 9-month-long series of mesurements of ozone in the upper stratosphere and mesosphere is reported. The measurements are presented as monthly averages of profiles in blocks of roughly 20 min local time and as night-to-day ratios. An error analysis predicts accuracies of 5-26% for the monthly profiles and 2.5-9% for the ratios. The data are compared to historical data from Solar Mesosphere Explorer (SME) and limb infrared monitor of the stratosphere (LIMS), and it is shown how to remove the effect of different vertical resolution from the comparisons. The microwave data typically agree to better than 10% with SMF and nighttime LIMS ozone at all altitudes below the 0.1-mbar surface. Comparison of the microwave night-to-day ratio with the corresponding ratio from LIMS suggests that nonlocal thermodynamic equilibrium effects in the LIMS daytime data exceed 10% at all pressures less than or equal to 1 mbar.

Connor, Brian J.↗

Model/data comparisons of ozone in the upper stratosphere and mesosphere

We compare ground-based microwave observations of ozone in the upper stratosphere and mesosphere with daytime observations made from the SME (Solar Mesosphere Explorer) satellite, with nighttime data from the LIMS instrument, and with a diurnal photochemical model. The results suggest that the data are all in reasonable agreement and that the model-data discrepancy is much less than previously thought, particularly in the mesosphere. This appears to be due to the fact that the latest data are lower than earlier reports and the updated model predicts more ozone than older versions. The model and the data agree to within a factor of 1.5 at all altitudes and typically are within 20 percent.

Siskind, David E.↗

Ground-based microwave monitoring of stratospheric ozone

A microwave instrument developed for operational measurements of ozone for the Network for Detection of Stratospheric Change is discussed. The instrument observes two spectral lines near 3-mm wavelength with a bandwidth of 630 MHz, allowing profile retrieval from 20 to 70 km. The observing technique and calibration procedures are described. The measurement forward model and retrieval algorithm are formulated. Preliminary comparisons with a colocated ground-based lidar and the SAGE II instrument are presented. The measurements are shown to typically agree to within 5 to 10 percent.

Parrish, A.↗

Detection of stratospheric ozone trends by ground-based microwave observations

We present an assessment of the trend detection capabilities of ground-based microwave measurements of ozone, focusing on the 20-60 km region. Uncertainty due to variable forward model and calibration errors is 3-5 percent; due to temperature profile errors, 1-2 percent; and due to spectral measurement errors, 1-3 percent. The measurement resolution is 8-10 km below 40 km, and increases to 17 km at 60 km. The net error for trend detection is 4-6 percent. Comparison with other measurements suggests interannual variations can be measured to 3-5 percent. We conclude a trend of 0.5 percent per year would be detected in about 10 years.

Connor, Brian J.↗