NIBS 2020 Reference Sheets

In preparation for NIBS 2020 various labs prepared reference sheets containing key information about their ion sources and the machines that they serve. The contents of the reference sheets have been formatted and edited into this paper for posterity and ease of access.

Welton, Robert F.↗

Upgraded millimeter-wave interferometer for measuring the electron density during the beam extraction in the negative ion source

The upgraded millimeter-wave interferometer with the frequency of 70 GHz is installed on a large-scaled negative ion source. Measurable line-averaged electron density is from 2 × 10{sup 15} to 3 × 10{sup 18} m{sup −3} in front of the plasma grid. Several improvements such as the change to shorter wavelength probing with low noise, the installation of special ordered horn antenna, the signal modulation for a high accuracy digital phase detection, the insertion of insulator, and so on, are carried out for the measurement during the beam extraction by applying high voltage. The line-averaged electron density is successfully measured and it is found that it increases linearly with the arc power and drops suddenly at the beam extraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charged particle flows in the beam extraction region of a negative ion source for NBI

Experiments by a four-pin probe and photodetachment technique were carried out to investigate the charged particle flows in the beam extraction region of a negative hydrogen ion source for neutral beam injector. Electron and positive ion flows were obtained from the polar distribution of the probe saturation current. Negative hydrogen ion flow velocity and temperature were obtained by comparing the recovery times of the photodetachment signals at opposite probe tips. Electron and positive ions flows are dominated by crossed field drift and ambipolar diffusion. Negative hydrogen ion temperature is evaluated to be 0.12 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Balmer-α spectrum measurements of the LHD one-third ion source

Wavelength spectra of Balmer-α light from plasmas in the extraction region of the Large Helical Device-R&D negative ion source, or the LHD one-third ion source have exhibited a blue shift as a negative bias voltage was applied to the plasma grid. The blue shift increased as the negative bias voltage with respect to the local plasma potential was increased. The measured spectra were compared with the velocity distributions of surface reflected hydrogen atoms calculated by atomic collisions in amorphous target code. The arc power and the source H{sub 2} pressure also affected the shift and broadening in the observed Balmer-α spectra. The possibility of identifying the negative hydrogen ions produced at the low work function plasma grid surface by high resolution spectroscopy is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optics of the NIFS negative ion source test stand by infrared calorimetry and numerical modelling

At National Institute for Fusion Science (NIFS), a multi-ampere negative ion source is used to support the R&D on H{sup −} production, extraction, and acceleration. In this contribution, we study the characteristics of the acceleration system of this source, in order to characterize the beam optics at different operational conditions. A dedicated experimental campaign was carried out at NIFS, using as main diagnostic the infra-red imaging of the beam profiles. The experimental measurements are also compared with 3D numerical simulations, in order to validate the codes and to assess their degree of reliability. The simulations show a satisfactory agreement with the experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Installation of spectrally selective imaging system in RF negative ion source

A spectrally selective imaging system has been installed in the RF negative ion source in the International Thermonuclear Experimental Reactor-relevant negative ion beam test facility ELISE (Extraction from a Large Ion Source Experiment) to investigate distribution of hydrogen Balmer-α emission (H{sub α}) close to the production surface of hydrogen negative ion. We selected a GigE vision camera coupled with an optical band-path filter, which can be controlled remotely using high speed network connection. A distribution of H{sub α} emission near the bias plate has been clearly observed. The same time trend on H{sub α} intensities measured by the imaging diagnostic and the optical emission spectroscopy is confirmed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement of accelerator of negative ion source on the Large Helical Device

To improve the performance of negative-ion based neutral beam injection on the Large Helical Device, the accelerator was modified on the basis of numerical investigations. A field limiting ring was installed on the upper side of a grounded grid (GG) support and a multi-slot GG was adopted instead of a multi-aperture GG. As a result, the voltage holding capability is improved and the heat load on the GG decreases by 40%. In addition, the arc efficiency is improved significantly only by replacing the GG.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time evolution of negative ion profile in a large cesiated negative ion source applicable to fusion reactors

To understand the physics of the cesium (Cs) recycling in the large Cs-seeded negative ion sources relevant to ITER and JT-60SA with ion extraction area of 45-60 cm × 110-120 cm, the time evolution of the negative ion profile was precisely measured in JT-60SA where the ion extraction area is longitudinally segmented into 5. The Cs was seeded from the oven at 180 °C to the ion source. After 1 g of Cs input, surface production of the negative ions appeared only in the central segment where a Cs nozzle was located. Up to 2 g of Cs, the negative ion profile was longitudinally expanded over full ion extraction area. The measured time evolution of the negative ion profile has the similar tendency of distribution of the Cs atoms that is calculated. From the results, it is suggested that Cs atom distribution is correlated with the formation of the negative ion profile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler shift measurement of Balmer-alpha line spectrum emission from a plasma in a negative hydrogen ion source

Balmer-α light emission from the extraction region of the LHD one-third ion source has shown a characteristic Doppler broadening in the wavelength spectrum detected by a high resolution spectrometer. The spectrum resembles Gaussian distribution near the wavelength of the intensity peak, while it has an additional component of a broader foot. The measured broadening near the wavelength of the intensity peak corresponds to 0.6 eV hydrogen atom temperature. The spectrum exhibits a larger expansion in the blue wing which becomes smaller when the line of sight is tilted toward the driver region from the original observation axis parallel to the plasma grid. A surface collision simulation model predicts the possibility of hydrogen reflection at the plasma grid surface to form a broad Balmer-α light emission spectrum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydrogen atom temperature measured with wavelength-modulated laser absorption spectroscopy in large scale filament arc negative hydrogen ion source

The velocity distribution function of hydrogen atoms is one of the useful parameters to understand particle dynamics from negative hydrogen production to extraction in a negative hydrogen ion source. Hydrogen atom temperature is one of the indicators of the velocity distribution function. To find a feasibility of hydrogen atom temperature measurement in large scale filament arc negative hydrogen ion source for fusion, a model calculation of wavelength-modulated laser absorption spectroscopy of the hydrogen Balmer alpha line was performed. By utilizing a wide range tunable diode laser, we successfully obtained the hydrogen atom temperature of ∼3000 K in the vicinity of the plasma grid electrode. The hydrogen atom temperature increases as well as the arc power, and becomes constant after decreasing with the filling of hydrogen gas pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of negative ion distribution changes by image processing diagnostic

Distributions of hydrogen Balmer-α (H{sub α}) intensity and its reduction behavior close to a plasma grid (PG) surface have been observed by a spectrally selective imaging system in an arc discharge type negative hydrogen ion source in National Institute for Fusion Science. H{sub α} reduction indicates a reduction of negative hydrogen ions because the mutual neutralization process between H{sup +} and H{sup −} ions causes the dominant excitation process for H{sub α} emission in the rich H{sup −} condition such as in ionic plasma. We observed a significant change in H{sub α} reduction distribution due to change in the bias voltage, which is used to suppress the electron influx. Small H{sub α} reduction in higher bias is likely because the production of negative ions is suppressed by the potential difference between the plasma and PG surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser photodetachment diagnostics of a 1/3-size negative hydrogen ion source for NBI

To investigate the flows of charged particles in front of the plasma grid (PG) in a negative hydrogen ion source, the information of the local densities of electrons and negative hydrogen ions (H-) are necessary. For this purpose, the laser photodetachment is applied for pure hydrogen plasmas and Cs-seeded plasma in a 1/3-size negative hydrogen ion source in NIFS-NBI test stand. The H- density obtained by photodetachment is calibrated by the results from cavity ring-down (CRD). The pressure dependence and PG bias dependence of the local H- density are presented and discussed. The results show that H- density increases significantly by seeding Cs into the plasma. In Cs-seeded plasma, relativity exists between the H- ion density and plasma potential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Research progress on ionic plasmas generated in an intense hydrogen negative ion source

Characteristics of ionic plasmas, observed in a high-density hydrogen negative ion source, are investigated with a multi-diagnostics system. The ionic plasma, which consists of hydrogen positive- and negative-ions with a significantly low-density of electrons, is generated in the ion extraction region, from which the negative ions are extracted through the plasma grid. The negative ion density, i.e., the ionic plasma density, as high as the order of 1×10{sup 17}m{sup −3}, is measured with cavity ring-down spectroscopy, while the electron density is lower than 1×10{sup 16}m{sup −3}, which is confirmed with millimeter-wave interferometer. Reduction of the negative ion density is observed at the negative ion extraction, and at that time the electron flow into the ionic plasma region is observed to conserve the charge neutrality. Distribution of the plasma potential is measured in the extraction region in the direction normal to the plasma grid surface with a Langmuir probe, and the results suggest that the sheath is formed at the plasma boundary to the plasma grid to which the bias voltage is applied. The beam extraction should drive the negative ion transport in the ionic plasma across the sheath formed on the extraction surface. Larger reduction of the negative ions at the beam extraction is observed in a region above the extraction aperture on the plasma grid, which is confirmed with 2D image measurement of the Hα emission and cavity ring-down spectroscopy. The electron distribution is also measured near the plasma grid surface. These various properties observed in the ionic plasma are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design, installation, commissioning and operation of a beamlet monitor in the negative ion beam test stand at NIFS

In the framework of the accompanying activity for the development of the two neutral beam injectors for the ITER fusion experiment, an instrumented beam calorimeter is being designed at Consorzio RFX, to be used in the SPIDER test facility (particle energy 100keV; beam current 50A), with the aim of testing beam characteristics and to verify the source proper operation. The main components of the instrumented calorimeter are one-directional carbon-fibre-carbon composite tiles. Some prototype tiles have been used as a small-scale version of the entire calorimeter in the test stand of the neutral beam injectors of the LHD experiment, with the aim of characterising the beam features in various operating conditions. The extraction system of the NIFS test stand source was modified, by applying a mask to the first gridded electrode, in order to isolate only a subset of the beamlets, arranged in two 3×5 matrices, resembling the beamlet groups of the ITER beam sources. The present contribution gives a description of the design of the diagnostic system, including the numerical simulations of the expected thermal pattern. Moreover the dedicated thermocouple measurement system is presented. The beamlet monitor was successfully used for a full experimental campaign, during which the main parameters of the source, mainly the arc power and the grid voltages, were varied. This contribution describes the methods of fitting and data analysis applied to the infrared images of the camera to recover the beamlet optics characteristics, in order to quantify the response of the system to different operational conditions. Some results concerning the beamlet features are presented as a function of the source parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of spectrally selective imaging system for negative hydrogen ion source

A spectrally selective imaging system has been developed to obtain a distribution of H{sub α} emissions at the extraction region in a hydrogen negative ion source. The diagnostic system consisted of an aspherical lens, optical filters, a fiber image conduit, and a charge coupled device detector was installed on the 1/3-scaled hydrogen negative ion source in the National Institute for Fusion Science. The center of sight line passes beside the plasma grid (PG) surface with the distance of 11 mm, and the viewing angle has coverage 35 mm from the PG surface. Two dimensional H{sub α} distribution in the range up to 20 mm from the PG surface was clearly observed. The reduction area for H{sub α} emission caused by beam extraction was widely distributed in the extraction region near the PG surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of plasma grid bias in large-scaled negative ion source

The electron density was measured at various bias voltages to understand how the plasma grid bias affects the electron near the plasma grid in large-scaled negative ion sources. It was found that the response of the electron to the bias voltage changes depending on negative ion production processes. The electron density remarkably decreases with increasing the bias voltage in the pure-volume plasma. On the other hand, the electron density depends on the bias voltage weakly in the Cs-seeded plasma. In addition, it was observed that the response of the co-extracted electron current to the bias voltage has similar trend to that of the electron density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of roughness and temperature on low-energy hydrogen positive and negative ion reflection from silicon and carbon surfaces

Angle-resolved energy distribution functions of positive and negative hydrogen ions produced from a rough-finished Si surface under 1 keV proton irradiation have been measured. The corresponding distribution from a crystalline surface and a carbon surface are also measured for comparison. Intensities of positive and negative ions from the rough-finished Si are substantially smaller than those from crystalline Si. The angular distributions of these species are broader for rough surface than the crystalline surface. No significant temperature dependence for positive and negative ion intensities is observed for all samples in the temperature range from 300 to 400 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3-D effects on viscosity and generation of toroidal and poloidal flows in LHD

Three-dimensional effects on plasma flows have been experimentally studied in the large helical device with 3D configurations. Spontaneous toroidal flow without net driving force using the combination of perpendicular neutral beam injection (NBI) heating and balanced tangential NBI heating has been investigated with two magnetic configurations. Co- and counter-directed spontaneous flows have been observed depending on the collisionality. Toroidal flow shear changes the sign at 0.4<r{sub eff}<0.6 between co- and counter-flowing plasmas, where r{sub eff} is a averaged minor radius. The detailed flow structures have been also examined at the edge region with stochastic magnetic field. A poloidal flow driven by the positive radial electric field has been observed at the open field region just outside of the plasma boundary. At the stochastic region, a shear of poloidal flow has been observed, while no shear of toroidal flow has been observed. The toroidal flow shear changes only in the nested magnetic flux surface region. A difference of density fluctuation property has been observed between co- and counter-flowing plasmas, where toroidal flow shears are formed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗