Search NASA⌕ Search

Engineering topics

Tupa, Dale

Publications and source records attributed to Tupa, Dale.

A TOPAS model for lens-based proton radiography

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

60 APPLIED LIFE SCIENCES↗

Development of Low-Power H - Proton Beam Capability in Area-A

A low-power proton beam capability in Area-A will support NNSA, LANL, Global Security, DoD, and Office of Science missions. It will also provide a stepping-stone towards other future uses of Area-A. We propose a cost-effective technical approach to achieve this goal. The main focus of this project will be to provide beam for a radiation effect beamline and a second pRad beamline.

43 PARTICLE ACCELERATORS↗

Gold leaf phantom development for the assessment of proton radiographic sensitivity limits simulating gold nanoparticle tagged tumors

Proton radiography may guide proton therapy cancer treatments with beam’s-eye-view anatomical images and a proton-based estimation of proton stopping power. However, without contrast enhancement, proton radiography will not be able to distinguish tumor from tissue. To provide this contrast, functionalized, high-Z nanoparticles that specifically target a tumor could be injected into a patient before imaging. We conducted this study to understand the ability of gold, as a high-Z, biologically compatible tracer, to differentiate tumors from surrounding tissue. We indicate that AuNP-enhanced proton radiography might be a feasible technology to provide image-guidance to proton therapy, potentially reducing off-target effects and sparing nearby tissue. These data can be used to develop treatment plans and clinical applications can be derived from the simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dark field proton radiography

A pre- and post-collimation scheme has been applied to high energy proton radiography to establish a dark field condition, which defaults to a state of no transmission until a scatterer is placed at the object plane. This technique, dark field proton radiography, provides two additional capabilities to a standard proton radiography setup. First, protons with a high degree of angular dispersion are removed from the beam, reducing the effects of chromatic aberrations and decreasing noise. Second, protons below the same threshold are removed from the beam downstream of the objects, effectively making the transmission highly sensitive to small amounts of scatter at the object plane. Finally, initial results indicate that the system is highly sensitive to the presence of thinner materials and improves sensitivity to subtle areal density variations in thick objects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strategies for seeking a job at a national lab [Slides]

Understanding the job market from the hiring side can help you develop better strategies for seeking a job. National laboratories represent a substantial source of jobs in the U.S. in engineering and science. High school, college, and graduate student internship positions are all available, but you can be more successful in finding one of these positions if you use a targeted search. Likewise, reaching out to individual researchers and/or knowing how to respond to job ads can increase your chances of getting an interview for a permanent job or positions, such as postdoc and postbac appointments, that can lead to permanent jobs. In my career as a research scientist at Los Alamos National Laboratory, I have hired people into all of these job categories, as well as served on many hiring committees for all levels of appointments. I will offer Polonius*-type advice for jobseekers and discuss the hiring process and how you can optimize your own job search.

99 GENERAL AND MISCELLANEOUS↗

LANSCE Pulse

For more than four decades, the United States has relied on the Los Alamos Neutron Science Center (LANSCE) accelerator to deliver high-energy, high-power proton beams in support of national security science. Today the LANSCE facility is a center for materials and nuclear research supporting National Nuclear Security Administration (NNSA) and Department of Energy (DOE) missions.

43 PARTICLE ACCELERATORS↗

Estimation of metal strength at very high rates using free-surface Richtmyer–Meshkov Instabilities

Recently, Richtmyer–Meshkov Instabilities (RMI) have been proposed for studying the average strength at strain rates up to at least 10 7 /s. RMI experiments involve shocking a metal interface that has initial sinusoidal perturbations. The perturbations invert and grow subsequent to shock and may arrest because of strength effects. In this work we present new RMI experiments and data on a copper target that had five regions with different perturbation amplitudes on the free surface opposite the shock. We estimate the high-rate, low-pressure copper strength by comparing experimental data with Lagrangian numerical simulations. From a detailed computational study we find that mesh convergence must be carefully addressed to accurately compare with experiments, and numerical viscosity has a strong influence on convergence. We also find that modeling the as-built perturbation geometry rather than the nominal makes a significant difference. Because of the confounding effect of tensile damage on total spike growth, which has previously been used as the metric for estimating strength, we instead use a new strength metric: the peak velocity during spike growth. Furthermore, this new metric also allows us to analyze a broader set of experimental results that are sensitive to strength because some larger initial perturbations grow unstably to failure and so do not have a finite total spike growth.

36 MATERIALS SCIENCE↗

Inverse-collimated proton radiography for imaging thin materials

Relativistic, magnetically-focused proton radiography was invented at Los Alamos National Laboratory using the 800 MeV LANSCE beam, and is inherently well-suited to imaging dense objects, at areal densities >20 g cm -2 . However, if the unscattered portion of the transmitted beam is removed at the Fourier plane through inverse-collimation, this system becomes highly sensitive to very thin media, of areal densities <100 mg cm -2 . Here, this inversecollimation scheme is described in detail and demonstrated by imaging Xe gas with a shockwave generated by an aluminum plate compressing the gas at Mach 8.8. With a 5-mrad inverse collimator, an areal density change of just 49 mg cm-2 across the shock front is discernible with a contrast-to-noise ratio of 3. Geant4 modeling of idealized and realistic proton transports can guide the design of inverse-collimators optimized for specific experimental conditions and show that this technique performs better for thin targets with reduced incident proton beam emittance. This work increases the range of areal densities to which the system is sensitive to span from ~25 mg cm -2 to 100 g cm -2 , exceeding three orders of magnitude. This enables the simultaneous imaging of a dense system, as well as thin jets and ejecta material that are otherwise difficult to characterize with high-energy proton radiography.

47 OTHER INSTRUMENTATION↗

Full report of laser doppler velocimetry (Het-V) data, results , and analysis for pRad shot 0632

This was a collaborative shot with AWE investigators Paul Willis-Patel, David Bell, Seth Grant, David Tarr, and James Richley. The shot was assembled in Los Alamos, after which David Bell set up the probe holder and finalized the alignment. The probe holder location and configuration was modified from previous years to make room for the laser illuminated visible imaging diagnostic. The LANL pRad PDV team was Dale Tupa, Amy Tainter, and Patrick Medina. This shot had three PDV probes: one aimed at the center, one aimed at a feature, one aimed at the reverse side of the shot. The shot also had 9 points of a spectroscopy diagnostic. The pRad team helped set up and field the spectroscopy, but did not help with any data analysis. (The support documentation for the PDV results includes a timing map for the spectroscopy.) Please direct questions on the velocimetry to Dale Tupa or Amy Tainter. The shot radiographs were classified, but the data from the optical diagnostics are not.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ejecta model development at pRad (u)

In July 2009 we fielded three explosively (HE) driven Richtmyer-Meshkov instability experiments at the LANSCE Proton Radiography Facility (pRad), and in August of 2009 we fielded one flyer plate experiment on the pRad 40 mm powder gun. One HE experiment was done in vacuum, and the other two within four atmospheres of noble gasses: Xe and Ne. These two gases were chosen to study the viscous effects on ejecta formation. It is unexpected, but the viscosity {eta} of Ne is twice that of Xe, and, due to the atomic mass difference between the two, the kinematic viscosity ({eta}/{rho}) of Ne is about ten times that of Xe. The results showed that ejecta formation is sensitively linked to the gas density, which implies that the Weber number is more important in ejecta formation than the Reynolds number.

99 GENERAL AND MISCELLANEOUS↗