Development of a Flight-Worthy 10 to 4 K Continuous Adiabatic Demagnetization Refrigerator

The cryogenics and fluids branch at NASA's Goddard Space Flight Center is currently developing a high-efficiency, vibration-free, flight-worthy Continuous Adiabatic Demagnetization Refrigerator (CADR) that consist of two modular units: one that lifts ~6 microW at 50 mK while rejecting its heat to a 4 K thermal sink, and another unit that provides a constant 4 K cooling stage while rejecting its heat to a thermal sink at 10 K. The two units are linked together via a 4 K common platform. This paper discusses the status report on the thermodynamic performance of the 4 -10 K ADR. This ADR utilizes an Nb3Sn superconducting magnet and Gadolinium Gallium Garnet (GGG) as its refrigerant. Results show that an idealized cycle, one where its hold time at 4 K is equal to the recycle time, can lift 13 mW at 4 K with a hold time of 132 seconds.

CADR↗

Vibration-Heating in ADR Kevlar Suspension Systems

The cryogenics group at NASA's Goddard Space Flight Center has a long-standing development and test program for laboratory and space-flight adiabatic demagnetization refrigerators (ADRs). These devices are used to cool components to temperatures as low as 0.05 K. At such low temperatures the ADR systems can provide a few micro-Watts of cooling power, so it is important to minimize the conduction of heat to these cold stages from the surroundings. The cold ADR elements are held in place by thin tensioned strings made of Kevlar, chosen for its high strength and stiffness and low thermal conductivity. During laboratory testing, we have observed that occasional significant additional heat loads on the coldest ADR stages correlate with unusually high vibration levels in the cryostat due to a noisy mechanical cryocooler. We theorized that this heat results from plastic deformation of the Kevlar fibers and frictional interactions among them, driven by the cryostat vibrations. We describe tests and calculations performed in attempt to confirm this source of the heating, and we discuss possible strategies to reduce this effect in future ADR suspension systems.

Vibration-heating↗

Development of a Space-Flight ADR Providing Continuous Cooling at 50 mK with Heat Rejection at 10 K

Future astronomical instruments will require sub-Kelvin detector temperatures to obtain high sensitivity. In many cases large arrays of detectors will be used, and the associated cooling systems will need performance surpassing the limits of present technologies. NASA is developing a compact cooling system that will lift heat continuously at temperatures below 50 mK and reject it at over 10 K. Based on Adiabatic Demagnetization Refrigerators (ADRs), it will have high thermodynamic efficiency and vibration-free operation with no moving parts. It will provide more than 10 times the current flight ADR cooling power at 50 mK and will also continuously cool a 4 K stage for instruments and optics. In addition, it will include an advanced magnetic shield resulting in external field variations below 5 µT. We describe the cooling system here and report on the progress in its development.

Tuttle, Jim↗

Development of a Space-Flight ADR Providing Continuous Cooling at 50 mK with Heat Rejection at 10 K

Future astronomical instruments will require sub-Kelvin detector temperatures to obtain high sensitivity. In many cases large arrays of detectors will be used, and the associated cooling systems will need performance surpassing the limits of present technologies. NASA is developing a compact cooling system that will lift heat continuously at temperatures below 50 mK and reject it at over 10 K. Based on Adiabatic Demagnetization Refrigerators (ADRs), it will have high thermodynamic efficiency and vibration-free operation with no moving parts. It will provide more than 10 times the current flight ADR cooling power at 50 mK and will also continuously cool a 4 K stage for instruments and optics. In addition, it will include an advanced magnetic shield resulting in external field variations below 5 T. We describe the cooling system here and report on the progress in its development.

space-flight↗

A High-Resolution Measurement of Ball IR Black Paint's Low-Temperature Emissivity

High-emissivity paints are commonly used on thermal control system components. The total hemispheric emissivity values of such paints are typically high (nearly 1) at temperatures above about 100 Kelvin, but they drop off steeply at lower temperatures. A precise knowledge of this temperature-dependence is critical to designing passively-cooled components with low operating temperatures. Notable examples are the coatings on thermal radiators used to cool space-flight instruments to temperatures below 40 Kelvin. Past measurements of low-temperature paint emissivity have been challenging, often requiring large thermal chambers and typically producing data with high uncertainties below about 100 Kelvin. We describe a relatively inexpensive method of performing high-resolution emissivity measurements in a small cryostat. We present the results of such a measurement on Ball InfraRed BlackTM(BIRBTM), a proprietary surface coating produced by Ball Aerospace and Technologies Corp (BATC), which is used in spaceflight applications. We also describe a thermal model used in the error analysis.

Tuttle, Jim↗

Mechanical Tensile Testing of Titanium 15-3-3-3 and Kevlar 49 at Cryogenic Temperatures

Titanium 15-3-3-3 and Kevlar 49 are highly desired materials for structural components in cryogenic applications due to their low thennal conductivity at low temperatures. Previous tests have indicated that titanium 15-3-3-3 becomes increasingly brittle as the temperature decreases. Furthermore, little is known regarding the mechanical properties of Kevlar 49 at low temperatures, most specifically its Young's modulus. This testing investigates the mechanical properties of both materials at cryogenic temperatures through cryogenic mechanical tensile testing to failure. The elongation, ultimate tensile strength, yield strength, and break strength of both materials are provided and analyzed here.

James, Bryan L.↗

Power Distribution for Cryogenic Instruments at 6-40K The James Webb Space Telescope Case

The Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST) operates its instruments passively cooled at around 40 Kelvin (K), with a warm Instrument Electronic Compartment (IEC) at 300K attached to it. From the warm electronics all secondary signal and power harnesses have to bridge this 300-40K temperature difference and minimize the power dissipation and parasitic heat leak into the cold region. After an introduction of the ISIM with its instruments, the IEC with the electronics, and the harness architecture with a special radiator, this paper elaborates on the cryogenic wire selection and tests performed to establish current de-rating rules for different wire types. Finally failure modes are analyzed for critical instrument interfaces that could inject excessive currents and heat into the harness and cold side, and several solutions for the removal of such failures are presented.

Rumler, Peter↗

JWST ISIM Harness Thermal Evaluation

The James Webb Space Telescope (JWST) will be a large infrared telescope with a 6.5-meter primary mirror. Launch is planned for 2013. JWST wl1 be the premier observatory of the next decade serving thousands of astronomers worldwide. The Integrated Science Instrument Module (ISIM) is the unit that will house thc four main JWST instruments. The ISIM enclosure passively cooled to 37 Kelvin and has a tightly managed thermal budget. A significant portion of the ISIM heat load is due to parasitic heat gains from the instrument harnesses. These harnesses provide a thermal path from the Instrument Electronics Control (IEC) to the ISIM. Because of the impact of this load to the ISIM thermal design, understanding the harness parasitic heat gains is critical. To this effect, a thermal test program has been conducted in order to characterize these parasitic loads and verify harness thermal models. Recent parasitic heat loads tests resulted in the addition of a dedicated multiple stage harness radiator. In order for the radiator to efficiently reject heat from the harness, effective thermal contact conductance values for multiple harnesses had to be determined. This presentation will describe the details and the results of this test program.

Kobel, Mark↗

Radiation Test Results for a MEMS Microshutter Operating at 60 K

The James Webb Space Telescope (JWST), the successor to the Hubble Space Telescope, is due to be launched in 2013 with the goal of searching the very distant Universe for stars that formed shortly after the Big Bang. Because this occurred so far back in time, the available light is strongly red-shifted, requiring the use of detectors sensitive to the infrared portion of the electromagnetic spectrum. HgCdTe infrared focal plane arrays, cooled to below 30 K to minimize noise, will be used to detect the faint signals. One of the instruments on JWST is the Near Infrared Spectrometer (NIRSPEC) designed to measure the infrared spectra of up to 100 separate galaxies simultaneously. A key component in NIRSPEC is a Micro-Electromechanical System (MEMS), a two-dimensional micro-shutter array (MSA) developed by NASA/GSFC. The MSA is inserted in front of the detector to allow only the light from the galaxies of interest to reach the detector and to block the light from all other sources. The MSA will have to operate at 30 K to minimize the amount of thermal radiation emitted by the optical components from reaching the detector array. It will also have to operate in the space radiation environment that is dominated by the MSA will be exposed to a large total ionizing dose of approximately 200 krad(Si). Following exposure to ionizing radiation, a variety of MEMS have exhibited performance degradation. MEMS contain moving parts that are either controlled or sensed by changes in electric fields. Radiation degradation can be expected for those devices where there is an electric field applied across an insulating layer that is part of the sensing or controlling structure. Ionizing radiation will liberate charge (electrons and holes) in the insulating layers, some of which may be trapped within the insulating layer. Trapped charge will partially cancel the externally applied electric field and lead to changes in the operation of the MEMS. This appears to be a general principle for MEMS. Knowledge of the above principle has raised the concern at NASA that the MSA might also exhibit degraded performance because, i) each shutter flap is a multilayer structure consisting of metallic and insulating layers and ii) the movement of the shutter flaps is partially controlled by the application of an electric field between the shutter flap and the substrate (vertical support grid). The whole mission would be compromised if radiation exposure were to prevent the shutters from opening and closing properly. energetic ionizing particles. Because it is located A unique feature of the MSA is that, as outside the spacecraft and has very little shielding, previously mentioned, it will have to operate at temperatures near 30 K. To date, there are no published reports on how very low temperatures (- 30K) affect the response of MEMS devices to total ionizing dose. Experiments on SiO2 structures at low temperatures (80 K) indicate that the electrons generated by the ionizing radiation are mobile and will move rapidly under the application of an external electric field. Holes, on the other hand, that would normally move in the opposite direction through the SiO2 via a "thermal hopping" process, are effectively immobile at low electric fields as they are trapped close to their generation sites. However, for sufficiently large electric fields (greater than 3 MV/cm) holes are able to move through the SiO2. The larger the field, the more rapidly the holes move. The separation of the electrons and holes leads to a reduced electric field within the insulating layer. To overcome this reduction in electric field, a greater external voltage will have to be applied that alters the normal operation of the device. This report presents the results of radiation testing of the MSA at 60 K. The temperature was higher than the targeted temperature because of a faulty electrical interconnect on the test board. Specifically, our goal was to determine whether the MSA would function propey after a TID of 200 krad(Si).

Rapchun, David A.↗

Low Temperature (30 K) TID Test Results of a Radiation Hardened 128 Channel Serial-to-Parallel Converter

This viewgraph presentation reviews the low temperature, Total Ionizing Dose (TID) tests of radiation hardened serial to parallel converter to be used on the James Webb Space Telescope. The test results show that the original HV583 level shifter - a COTS part -was not suitable for JWST because the supply currents exceeded specs after 20 krad( Si) .The HV584 - functionally similar to the HV583 -was designed using RHBD approach that reduced the leakage currents to within acceptable levels and had only a small effect on the level-shifted output voltage.

Meyer, Stephen↗

A 10 Kelvin 3 Tesla Magnet for Space Flight ADR Systems

Many future space flight missions are expected to use adiabatic demagnetization refrigerators (ADRs) to reach detector operating temperatures well below one Kelvin. The goal is to operate each ADR with a mechanical cooler as its heat sink, thus avoiding the use of liquid cryogens. Although mechanical coolers are being developed to operate at temperatures of 6 Kelvin and below, there is a large efficiency cost associated with operating them at the bottom of their temperature range. For the multi-stage ADR system being developed at Goddard Space Flight Center, the goal is to operate with a 10 Kelvin mechanical cooler heat sink. With currently available paramagnetic materials, the highest temperature ADR stage in such a system will require a magnetic field of approximately three Tesla. Thus the goal is to develop a small, lightweight three Tesla superconducting magnet for operation at 10 Kelvin. It is important that this magnet have a low current/field ratio. Because traditional NbTi magnets do not operate safely above about six Kelvin, a magnet with a higher Tc is required. The primary focus has been on Nb3Sn magnets. Since standard Nb3Sn wire must be coated with thick insulation, wound on a magnet mandrel and then reacted, standard Nb,Sn magnets are quite heavy and require high currents Superconducting Systems developed a Nb3Sn wire which can be drawn down to small diameter, reacted, coated with thin insulation and then wound on a small diameter coil form. By using this smaller wire and operating closer to the wire s critical current, it should be possible to reduce the mass and operating current of 10 Kelvin magnets. Using this "react-then-wind" technology, Superconducting Systems has produced prototype 10 Kelvin magnets. This paper describes the development and testing of these magnets and discusses the outlook for including 10 Kelvin magnets on space-flight missions.

Tuttle, Jim↗

A Miniature Palladium-Iron Thermometer for Temperatures Down to 0.05 K

Magnetic thermometers are appealing at temperatures below about 0.1 Kelvin, because the avoid the noise self-heating problems associated with resistive thermometers. In practical, metallic dilute electronic thermometers add the advantages of chemical stability, high thermal conductivity, and easy in heat sinking work we describe a palladium-iron thermometer which was designed to be small and conveniently packaged and optimized for use at temperatures down to 0.05 Kelvin. The device showed Curie-Weiss behavior above about 0.06 Kelvin, and we achieve 41 nK/ square root of z temperature resolution at a temperature of 49 mK. We describe the design and operation of this thermometers and present the test results.

Tuttle, Jim↗

The HAWC and SAFIRE Adiabatic Demagnetization Refrigerators

The High-Resolution Airborne Wide-band Camera (HAWC) and Submillimeter and Far Infrared Experiment (SAFIRE) are far-infrared experiments which will fly on the Stratospheric Observatory for Infrared Astronomy (SOFIA) aircraft. HAWC's detectors will operate at 0.2 Kelvin, while those of SAFIRE will be at 0.1 Kelvin. Each instrument will include an adiabatic demagnetization refrigerator (ADR) to cool its detector stage from the liquid helium bath temperature (HAWC's at 4.2 Kelvin and SAFIRE's pumped to about 1.3 Kelvin) to its operating temperature. Except for the magnets used to achieve the cooling and a slight difference in the heat switch design, the two ADRs are nearly identical. We describe the ADR design and present the results of performance testing.

Tuttle, Jim↗

Superfluid Helium On-Orbit Transfer (SHOOT) flight demonstration

The Superfluid Helium On-Orbit Transfer (SHOOT) Flight Demonstration was an attached Shuttle payload mounted on a Hitchhiker cross-bay carrier which flew on STS-57 in June of 1993. SHOOT successfully demonstrated the handling and transfer of superfluid helium between two containers, called dewars, in low gravity. SHOOT was a class C payload and for the STS-57 mission was termed a complex secondary payload. The primaries were the retrieval of the EURECA carrier and a collection of modular experiments contained in SPACEHAB. Because the liquid helium was continuously boiling off, SHOOT's activities were scheduled for the first three days of the mission, concurrent with some SPACEHAB experiments, but well before the EURECA retrieval. Control of the SHOOT experiment was highly interactive and originated primarily from the Goddard Payload Operations and Control Center (POCC). Transfer and calibration activities required continuous command windows of up to 50 minutes duration and up to 80 minutes out of each orbit. Occasionally the crew controlled the experiment using the Payload General Support Computer (PGSC) when near-real time control and monitoring was required. SHOOT also placed considerable demands on the orbiter, including a pitch rotation of 3 deg./sec for 15 minutes, and translational burns using both the aft and forward RCS jets to generate accelerations up to 7 milli-g. The basis for these and other requirements are discussed. Interacion with the crew and timing of crew activity during the mission will be detailed. The processing flow of SHOOT at KSC is described with emphasis on the tradeoffs for vertical, as opposed to horizontal, installation in the orbiter. Finally, some lessons learned are presented that are relevant to future cryogenic and Hitchhiker payloads.

Shirron, Peter↗