Search NASA⌕ Search

Engineering topics

Tuzzolino, A. J.

Publications and source records attributed to Tuzzolino, A. J..

At least 19 records

Stardust Encounters Comet 81P/Wild 2

Stardust successfully encountered comet 81P/Wild 2 on 2 January 2004 at a distance of 236.4 +/- 1 km. All encounter investigations acquired valuable new and surprising findings. The time-of-flight spectrometer registered 29 spectra during flyby and measured the first negative ion mass spectra of cometary particles. The dust detectors recorded particles over a broad mass range, 10(exp -11) to 10(exp -4) g. Unexpectedly, the dust distribution along Stardust's flight path was far from uniform, but instead occurred in short 'bursts', suggesting in-flight breakup of fragments ejected from the nucleus. High-resolution, stunning images of the Wild 2 surface show a diverse and complex variety of landforms not seen from comets 1P/Halley and 19P/Borrelly or icy satellites of the outer solar system. Longer-exposure images reveal large numbers of jets projected nearly around the entire perimeter of the nucleus, many of which appear to be highly collimated. A triaxial ellipsoidal fit of the Wild 2 nucleus images yields the principal nucleus radii of 1.65 X 2.00 X2.75 km (+/- 0.05 km). The orientations and source locations on the nucleus surface of 20 highly collimated and partially overlapping jets have been traced. There is every indication that the expected samples were successfully collected from the Wild 2 coma and are poised for a return to Earth on 15 January 2006.

Stardust mission↗

In-Situ Detections of a Satellite Breakup by the SPADUS Experiment

For the first time, a particle detector in Earth orbit has provided evidence to directly link sub-millimeter orbital debris to a specific satellite breakup. The University of Chicago's Space Dust instrument (SPADUS), on the U.S. Air Force's Advanced Research and Global Observation Satellite (ARGOS), has been operating in a nearly polar orbit at an altitude of about 830 km since soon after its launch on 23 February 1999. The experiment was designed primarily to detect small natural and man-made particles less than 100 microns in diameter. Using a dual-plane Polyvinylidene Fluoride (PVDF)-based detection system, SPADUS can measure dust particle flux, mass distribution, velocity, and trajectory. During its first year in orbit, SPADUS recorded 195 impacts, about one impact every two days. In late March 2000 the instrument detection rate soared by approximately an order of magnitude, suggesting a potential encounter with a cloud or stream of debris. A review of the impact times and ARGOS orbital characteristics indicated that most of the detections occurred at multiples of half-revolution intervals deep in the northern and southern hemispheres, with a clear majority of impacts found in the latter. Orbital analyses linked these impact events to the orbital plane intersections of ARGOS and the debris cloud of a Chinese orbital stage (International Designator 1999-057C, US Satellite Number 25942) which had undergone a severe fragmentation on 11 March 2000 at an altitude 100 km below that of ARGOS. Approximately 40 of the SPADUS detections during the period 25 March 1 April could be associated with the postulated Chinese debris cloud. Other periods of high impact flux on SPADUS may be related to debris clouds from different sources.

Tuzzolino, A. J.↗

The DROPPS Program: A Rocket/Lidar/Radar Study of the Polar Summer Mesosphere

During July of 1999, two sequences of rockets were launched from the Norwegian rocket range in Andoya, Norway. The purpose of these studies was to investigate the properties of the polar summer mesosphere, particularly relating to polar mesospheric summer echoes (PMSE) and their possible relationship to noctilucent clouds (NLC). Each of two sequences was anchored with a DROPPS Black Brant payload, consisting of 20 instruments to measure the electrodynamic and optical structure of the mesosphere and lower thermosphere. These were provided by participants from five American and two European scientific laboratories. The DROPPS (Distribution and Role of Particles in the Polar Summer) payloads were each accompanied by a sequence of meteorological rockets, and by several European payloads designed to study electrodynamics structure of the same region. ALOMAR (Arctic Lidar Observatory for Middle Atmosphere Research) Lidars, and MF (Medium Frequency) and MST (Mesosphere, Stratosphere, and Troposphere) Radars were used to continuously monitor the mesosphere for NLCs and PMSEs respectively. EISCAT VHF (European Incoherent Scatter Radar Very High Frequency) radar provided similar information about PMSEs downstream from the launch site. Sequence 1 was launched on the night of 5-6 July into a strong PMSE display coupled with a weak NLC at the low end of the PMSE. Sequence 2 was launched on the early morning of 14 July into a strong NLC with no PMSE evident. Here we describe the details of the program along with preliminary results.

Goldberg, Richard A.↗

Measurements of micron-scale meteoroids and orbital debris with the Space Dust (SPADUS) instrument on the upcoming ARGOS P91-1 mission

The space dust (SPADUS) experiment, to be launched into a sun-synchronous polar orbit at an altitude of 833 km onboard the USAF ARGOS P91-1 mission, will provide time-resolved measurements of the intensity, size spectrum and geocentric trajectories of dust particles encountered during the nominal three year mission. The experiment uses polyvinylidene fluoride dust sensors with a total detector area of 576 sq cm. The SPADUS will measure particle sizes between 2 and 200 microns, particle velocities between 1 and 10 km/s to better than 4 percent, and the direction of incidence with a mean error of 7 percent. These data will identify the particles as being debris or of natural origin.

McKibben, R. B.↗

The orbital debris detector consortium: Suppliers of instruments for in-situ measurements of small-particles in the space environment

Industry and university participants have joined together to form the IMPA:Ct consortium (In-situ Monitors of the Particulate Ambient: Circumterrestrial) which offers a broad range of flight qualified instruments for monitoring the small particle (0.1 micron to 10 cm) environment in space. Instruments are available in 12 months or less at costs ranging from 0.5 to 1.5 million dollars (US) for the total program. Detector technologies represented by these groups are: impact-induced capacitor-discharge (MOS, metal-oxide-silicon), cratering or penetration of electroactive thin film (polyvinylidene fluoride (PVDF)), impact-plasma detection, acoustic detection, CCD tracking of optical scatter of sunlight, and photodiode detection of optical scatter of laser light. The operational characteristics, general spacecraft interface and resource requirements (mass/power/telemetry), cost and delivery schedules, and points of contact for seven different instruments are presented.

Simon, C. G.↗

An LDEF 2 dust instrument for discrimination between orbital debris and natural particles in near-Earth space

The characteristics of a space dust instrument which would be ideally suited to carry out near-Earth dust measurements on a possible Long Duraction Exposure Facility reflight mission (LDEF 2) is discussed. As a model for the trajectory portion of the instrument proposed for LDEF 2, the characteristics of a SPAce DUSt instrument (SPADUS) currently under development for flight on the USA ARGOS mission to measure the flux, mass, velocity, and trajectory of near-Earth dust is summarized. Since natural (cosmic) dust and man-made dust particles (orbital debris) have different velocity and trajectory distributions, they are distinguished by means of the SPADUS velocity/trajectory information. The SPADUS measurements will cover the dust mass range approximately 5 x 10(exp -12) g (2 microns diameter) to approximately 1 x 10(exp -5) g (200 microns diameter), with an expected mean error in particle trajectory of approximately 7 deg (isotropic flux). Arrays of capture cell devices positioned behind the trajectory instrumentation would provide for Earth-based chemical and isotopic analysis of captured dust. The SPADUS measurement principles, characteristics, its role in the ARGOS mission, and its application to an LDEF 2 mission are summarized.

Tuzzolino, A. J.↗

Confirmation of dust clusters in the coma of Comet Halley

Measurements from the Ducma dust counter and mass analyzer on the Vega spacecraft are compared with those from the SP-1 sensor on the same spacecraft. It is shown that the sequence of pulses recorded by the SP-1 instruments show deviations from a random distribution. Some of the nonrandom sequences observed by SP-1 are in the same time intervals as the clusters observed by the Ducma instrument. The results support the analysis of Ducma data which showed highly structured variations of dust intensity through the coma and large fluxes of low mass particles extending to great distances beyond the coma (Simpson et al., 1986).

Simpson, J. A.↗

Trajectory-capture cell instrumentation for measurement of dust particle mass, velocity and trajectory, and particle capture

The development of the polyvinylidene fluoride (PVDF) dust detector for space missions--such as the Halley Comet Missions where the impact velocity was very high as well as for missions where the impact velocity is low was extended to include: (1) the capability for impact position determination - i.e., x,y coordinate of impact; and (2) the capability for particle velocity determination using two thin PVDF sensors spaced a given distance apart - i.e., by time-of-flight. These developments have led to space flight instrumentation for recovery-type missions, which will measure the masses (sizes), fluxes and trajectories of incoming dust particles and will capture the dust material in a form suitable for later Earth-based laboratory measurements. These laboratory measurements would determine the elemental, isotopic and mineralogical properties of the captured dust and relate these to possible sources of the dust material (i.e., comets, asteroids), using the trajectory information. The instrumentation described here has the unique advantages of providing both orbital characteristics and physical and chemical properties--as well as possible origin--of incoming dust.

Simpson, J. A.↗

The dust coma of comet P/Halley - Measurements on the Vega-1 and Vega-2 spacecraft

Measurements obtained with the Dust Counter and Mass Analyzer instruments on the Vega 1 and 2 spacecraft are used to study properties of the coma of comet P/Halley. Well-defined envelope boundaries for the inverse square dependence of flux with distance from the nucleus are found, and regions of enhanced fluxes above these R exp -2 baselines inside these boundaries are identified as dust jets. The mass spectrum of the giant flux enhancement noted near the closest approach of Vega 1 is shown to be similar to the preencounter spectra. The data suggest the emission from the nucleus of large conglomerates of small particles which disintegrate as they travel outward, explaining the 10 to the -13th g particles observed beyond the envelope boundaries.

Simpson, J. A.↗

The origin of low mass particles within and beyond the dust coma envelopes of Comet Halley

Measurements from the Dust Counter and Mass Analyzer (DUCMA) instruments on VEGA-1 and -2 revealed unexpected fluxes of low mass (up to 10 to the minus 13th power g) dust particles at very great distances from the nucleus (300,000 to 600,000 km). These particles are detected in clusters (10 sec duration), preceded and followed by relatively long time intervals during which no dust is detected. This cluster phenomenon also occurs inside the envelope boundaries. Clusters of low mass particles are intermixed with the overall dust distribution throughout the coma. The clusters account for many of the short-term small-scale intensity enhancements previously ascribed to microjets in the coma. The origin of these clusters appears to be emission from the nucleus of large conglomerates which disintegrate in the coma to yield clusters of discrete, small particles continuing outward to the distant coma.

Simpson, J. A.↗

Dust counter and mass analyser (DUCMA) measurements of comet Halley's coma from Vega spacecraft

Measurements of dust particles in comet Halley's coma from Vega spacecraft made with instruments using a new principle of dust detection and having a high time resolution over a large range of dust fluxes and masses are reported. The dust coma, whether quiescent (as seen by Vega 2) or containing a major jet structure, (as seen by Vega 1) displays large, short-term variations throughout which are at times quasi-periodic. The integral mass spectra increase in intensity to the lowest masses measured, and the flux levels lie approximately in the ranges estimated previously from ground-based observations. The coma is highly dynamical on all spatial and temporal scales, suggesting a complex structure of localized regions of dust emission from the nucleus.

Simpson, J. A.↗

A new instrument to measure charged and neutral cometary dust particles at low and high impact velocities

A new class of dust particle detector, the PVDF dust detector, was designed for space missions such as the Halley Comet missions where the particle impact velocity is very high. It is demonstrated that this same PVDF detector (operating in a different mode) also has the capability of detecting dust particles having low velocity (approx. 100 m/s). This low velocity detection capability is extremely important in terms of planned missions requiring measurement of low velocity dust particles such as comet rendezvous missions. An additional detecting element (charge induction cylinder) was also developed which, when combined with a PVDF detector, yields a system which will measure the charge (magnitude and sign) carried by a cometary particle as well as the particle velocity and mass for impact velocities in the range 100 to 500 m/s. Since the cylinder-PVDF detector system has a relatively small geometry factors, an array of PVDF detectors was included having a total sensing area of 0.1 sq m for measurements in regions of space where the dust flux is expected to be low. The characteristics of the detectors in this array have been chosen to provide optimum mass sensitivity for both low-velocity cometary dust as well as high-velocity asteroid associated and interplanetary dust.

Economon, T.↗

A cometary and interplanetary dust experiment on the Vega spacecraft missions to Halley's Comet

The dust counter and mass analyzer on board both the Vega 1 and Vega 2 spacecraft scheduled to encounter Halley's Comet are discussed. The operational modes, data formats, telemetry modes and data acquisition, and scientific measurements planned for this experiment both at encounter and during interplanetary travel are described. The initial postlaunch calibration and experiment status are summarized in an appendix.

Perkins, M. A.↗

Polarized polymer films as electronic pulse detectors of cosmic dust particles

A new type of dust particle detector has been developed which consists of a polarized film of polyvinylidene fluoride (PVDF) having conducting electrons on its surface and operating with no bias voltage. Here, the response characteristics of PVDF detectors with areas in the range 4-150 sq cm and thickness in the range 2-28 microns to iron particles accelerated to velocities in the range 1-12 km/s are reported. The discussion also covers the mechanism of detection, fast pulse response, noise characteristics, and the dependence of the detector signal amplitude on particle mass and velocity. The detectors exhibit long-term stability and can be operated for extended periods of time over the temperature range -50 to +50 C; their response to dust particle impacts is unaffected by high background fluxes of charged particles.

Simpson, J. A.↗

Pyroelectric materials as electronic pulse detectors of ultraheavy nuclei

The design and testing of ultraheavy-nucleus pulse detectors based on pyroelectric materials are reported, extending the preliminary findings of Tuzzolino (1983) and Simpson and Tuzzolino (1983). Uranium-ion beams of about 240 MeV/u are detected by a 39.5-micron-thick Si detector, degraded to about 175 MeV/u by Al absorbers, and then strike 700-micron-thick polyvinylidene fluoride or 1000-micron-thick LiTaO3 pyroelectric samples. Both detector systems are connected to a coincidence circuit via charge-sensitive preamplifiers, shaping amplifiers with 30-microsec effective time constants, and electronic discriminators. Sample spectra are shown, and the pulse heights measured are found to agree with theoretical calculations to within a factor of about 2. The response of the pyroelectric materials is found to be unaffected by exposure to about 10 Mrad of 2-7-MeV/u heavy ion radiation. With further study and improvement of the detection sensitivity, devices of this type could be applied to large-area space measurements of low ultraheavy-ion fluxes.

Simpson, J. A.↗

Electronic detection of ultra-heavy nuclei by pyroelectric materials

A recent prediction by the authors that pyroelectric materials may be capable of detecting ultra-heavy nuclei has been confirmed. Charge pulse signals from pyroelectric crystals of lithium tantalate exposed to Au ions and a pulsed beam of Ni-58 ions, and from pyroelectric films of polyvinylidene fluoride exposed to a pulsed beam of Ni-58 ions, have been measured using pulse electronics with time constants in the microsecond range. These studies show that pyroelectric materials, in general, are capable of detecting incident nuclei having very high mass and charge. In particular, pyroelectric polymers, such as polyvinylidene fluoride, are readily available as inexpensive flexible films. This new class of charged particle detector could eventually find applications in large-area experiments for detection and trajectory determination of low-energy, ultra-heavy nuclei.

Simpson, J. A.↗

Saturnian trapped radiation and its absorption by satellites and rings - The first results from Pioneer 11

Preliminary results from Pioneer 11 concerning the acceleration and trapping of charged particles in the magnetic field of Saturn are reported. The identification and measurement of the intensities and spectra of charged particle species was performed by an experiment including four charged particle sensor systems, within 20 Saturn radii of the planet. Increases in the intensity of 0.5- to 1.8-MeV protons within 15 Saturn radii indicate the trapping and acceleration of particles in the dipole field region, while a decrease in proton intensity between seven and four Saturn radii is attributed to absorption by Dione and Enceladus and possibly ring material as well. Proton and electron intensity distributions are found to be axially symmetric within four Saturn radii, indicating a centered dipole aligned with the planetary rotation axis. Trapped radiation absorption at the orbit of Mimas is analyzed to obtain an upper limit of 4 x 10 to the -8th Saturn radii-squared/sec to the inward diffusion coefficient; an absorption-like feature observed at L = 2.5 is attributed to a previously unidentified satellite of diameter less than 200 km and semimajor axis 2.51 Saturn radii. Radiation absorption by the newly discovered F ring was also observed, however beneath the A, B and C rings a low flux of high-energy electrons was detected.

Simpson, J. A.↗

Electron calibration of instrumentation for low energy, high intensity particle measurements at Mercury

Unique identification of the high intensity, impulsively accelerated charged particle fluxes discovered during Mariner 10's first encounter with Mercury (March 1974) requires a detailed knowledge of the responses of the two University of Chicago charged particle telescopes to low energy fluxes over a wide dynamic range of flux levels. The results of detailed analyses show that these telescopes can separate and identify unambiguously the presence of electron and proton fluxes for a wide range of electron spectra and intensities in the relevant overall range of about 30 keV to 2 MeV.

Christon, S. P.↗