Search NASA⌕ Search

Engineering topics

Tyler B. Hudson

Publications and source records attributed to Tyler B. Hudson.

Offset-Stoichiometric Reflowable Composite Bonding Method with Adhesive for Mitigating Strict Faying Surface Tolerances

Inherent susceptibility of adhesive bonds to miniscule quantities of contamination can cause undetectable weakened bonds. For this reason, the Federal Aviation Administration (FAA) places strict regulations on adhesively bonded joints in primary aircraft structures. To meet certification requirements aircraft manufactures resort to redundant load paths in the form of fasteners which inherently add weight to the structure and increase manufacturing time. In prior work, a secondary bonding technique called AERoBOND was developed, which utilized off-stoichiometric epoxymatrix resins to facilitate reflow and diffusion of the resin within the joint interface during a secondary bonding/cure process, thus achieving a bond similar to a co-cured joint. However, the AERoBOND process required tight spatial tolerances between the two parts being joined. This study examined the utilization of conventional adhesive with the AERoBOND method to act as a filler in the joint line, effectively reducing the need for tight tolerances on the joining parts and serving as a flexible alternative for existing manufacturing processes. Ultrasonic inspection, optical microscopy, and ASTM International standard tests were performed to analyze the joints for defects and to quantify the mode-I and mode-II interlaminar fracture toughness and short beam strength of the proposed methodology with varying manufacturing parameters. The comprehensive results indicate that the AERoBOND+ method with and without surface preparation performs comparably to co-cured and conventional, adhesively bonded joints when secondary cured in an autoclave with 791 kPa of pressure. As an example, the AERoBOND+ panel without surface preparation bonded with 791 kPa of pressure (referred to as AB+3 throughout paper) had a mode-I fracture toughness (G Ic ) of 0.643 kJ/m 2 and a mode-II fracture toughness (G IIc ) of 4.000 kJ/m 2 in the non-precracked condition and 4.218 kJ/m 2 in the precracked condition at the adhesive-to-prepreg interface. These results were 96%, 142%, and 217%, respectively, of a co-cured baseline panel (referred to as C1 throughout paper).

Composites↗

Molecular Dynamics Investigation of the Structural and Mechanical Properties of Off-Stoichiometric Epoxy Resins

Molecular dynamic (MD) simulations were performed to compute the mechanical properties of off-stoichiometric epoxy resins as a function of hardener/epoxy mixture ratio (r). Properties were characterized in relation to their microscopic structures. Such resins have been used recently for adhesive-free bonding of large-scale composite structures using the co-curing-ply method. In this process, two partially precured composite panels with hardener-poor (HP) off-stoichiometric resins are coupled with ply(ies) of complementary hardener-rich (HR) formulations and then cured simultaneously. This bonding process has the potential to produce reliable and certifiable composite joints without the need for additional fasteners, which are often required for many conventional bonding methods because even small amounts of contamination can cause a weak bond. The reflow and mixing of the HP/HR resin in this bonding process result in a joint with no discernable interface that should not be susceptible to surface contamination. However, incomplete mixing of the two offset resins may result in chemical heterogeneity of the cured polymeric joint. Thus, different r values may be obtained across the joint. Classical MD simulations were performed to compute the Young’s modulus of polymers with different r values and correlate their properties to network structures. High stiffness was associated with molecular packing due to chemical crosslinking, leading to a single network structure. Moreover, the networks became denser as the ratio approached the stoichiometric value r = 1. Thus, the r = 1 systems were single clusters, with high stiffness, high molecular weight, and a high degree of crosslinking. Structural properties such as radius of gyration and mean square displacement were determined to investigate the variation in the stiffness with respect to r. This MD simulation study was validated with experimental measurements.

Chang Woon Jang↗

Porosity Detection and Localization During Composite Cure Inside an Autoclave Using Ultrasonic Inspection

Composite materials offer unique benefits in aerospace applications such as increased strength-to-weight ratio and improved fatigue properties. They are increasingly being used in major commercial aircraft programs. However, current processing methods can lead to defects in composite parts, which must be detected using post-manufacturing inspection methods. Porosity (i.e., pores, voids) is a critical defect from the cure process that is detrimental to performance of the composite part. It is therefore necessary to understand and eliminate the formation of porosity defects. At NASA Langley Research Center, an in-situ cure monitoring system was developed to detect porosity defects as they form in real-time inside an autoclave. A capability to directly detect and localize porosity within a composite during cure did not exist before. This study is focused on an elevated-temperature ultrasonic inspection system to detect porosity defects in composites during autoclave cure. The ultrasonic inspection system operated inside an autoclave within an enclosure cooled by intermittent liquid nitrogen (LN_2) injections. A high-temperature, 2.25 MHz, transducer transmitted ultrasonic waves through the tool plate and into the composite part and measured the amplitude and time of flight of the reflected waves with a 1 mm × 1 mm step size/areal resolution. Porosity was observed via the ultrasonic reflections, which experienced increased attenuation in regions of high porosity. Distinct regions of increased porosity were present due to uneven pressure across the panel, which was driven by an intentional misfit between the flat caul plate and the tapered composite panel with ply drops. The results were validated by post-cure ultrasonic inspection and micrographs. The in-situ inspection system was able to successfully provide porosity detection and localization in the tapered ply-drop panel. The successful results indicate the promise of this system for future implementation in the manufacturing of composite structures for aerospace applications.

Composites↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods.This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel. An ultrasonic scanner was enclosed in a nitrogen-cooled insulating box that prevented thermal damage from the industrial oven to the temperature-sensitive electronics. Inspection of the composite part was performed through the bottom of the enclosure, which served as the tool plate for the part. In this study, a porosity gradient was introduced through a misfit of the part and caul plate. Using the data obtained from B-scans and amplitude C-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

In-process, Defect Detection, Cure Monitoring, Por↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Latent Cure Epoxy Matrix Resins for Reliable Assembly of Thermoset Composite Structures

Polymer matrix composites are used in high performance structures because of their excellent specific strength, toughness, and stiffness. To realize their full potential, complex composite structures must be assembled with adhesive, but uncertainty in bond performance often requires manufacturers to install bolts or other crack-arrest features to ensure safety in critical applications.1 The inherent uncertainty in adhesive bonds stems from the material discontinuity at the composite-to-adhesive interfaces, which are susceptible to contamination and other causes of inter-facial weakness.2 In contrast, co-cured composites, although limited in size and complexity, result in predictable structures that may be certifiable for commercial aviation with reduced dependence on redundant load paths.1 The technology proposed here uses a stoichiometric offset of the hardener-to-epoxy ratio on the faying surfaces of epoxy compo-site laminates. Assembly of the components in a subsequent “secondary co-cure” process results in a joint with no material discontinuities (Figure 1)

Frank L. Palmieri↗

NASA's Composite Overwrap Lessons Learned on 40k Thrust Chamber Assemblies

Filament wound carbon fiber/polymer composite overwraps combined with additively manufactured (AM) copper alloy combustion chambers are a critical part of NASA’s Rapid Analysis and Manufacturing Propulsion Technology (RAMPT) project. The composite overwrap is a high strength-to-weight material and allows for significant weight reduction of the high-pressure thrust chamber assembly, reduction of overall cost, and reduced fabrication time while offering structural robustness. Integrated AM/composite overwrap chamber assemblies using 2,000 lbf (2k) and 7,000 lbf (7k) thrust were successfully hot fire tested at NASA Marshall Space Flight Center (MSFC). These assemblies allowed the team to learn lessons related to the design, analysis, and manufacturing of these integrated assemblies. A final goal of the RAMPT project is to design and test a 40,000 lbf (40k) thrust chamber assembly. The40k chamber presented the team several new challenges including an integral inlet port in the main body of the composite overwrap. Through multiple iterations of manufacturing techniques, varied materials, and Non-Destructive Evaluations (NDE), many lessons were learned to obtain a final design solution that would not only allow for the interrupted port inlet but also allow for sufficient material margins for the most critically stressed part of the chamber. This paper will cover the manufacturing techniques exploring fabric designs to help subsidize the coverage in the areas left bare by the inlet port during the filament winding process and custom tooling needed for the final full chamber processing. The original material choice of bismaleimide (BMI) 5250-4 from the 7k chamber performed well for the extreme environment of hot fire testing but proved to be difficult with the increased scale and interrupted port design of the 40kchamber. Discussion in this paper will cover these changes, including evaluation of the design, comparison to the prior 2k and 7k designs, and show the final hardware that will be tested. One primary goal of this work and RAMPT project is to provide this development process and data to industry for infusion into future engine designs.

Filament Wound↗

Joining Composite Parts With Off-Stoichiometric Matrix Reflow

Adhesive bonding is an attractive alternative to fasteners for composite part assembly. In addition to superior performance, it reduces weight and eliminates costly manufacturing processes. However, current adhesive bonding methods are highly susceptible to contamination flaws, and it is difficult to verify bonds because nondestructive testing to quantify bond strength is still under development. In aerospace applications, this often results in fasteners being added to provide redundant load paths. Co-cured parts can provide an alternative because they can be inspected using traditional nondestructive evaluation techniques such as ultrasound. However, co-curing can only be accomplished for a limited range of geometries. NASA’s Adhesive Free Bonding of Composites (AERoBOND) is an alternative method for bonding composite parts. The goal of this study was to further develop and understand the capabilities of this novel bonding technique.

Charles T. Dolph↗

Composite Bond Line Measurements Based on A Bayesian Analysis of Flash Thermography Data

For bonded composite materials, an accurate characterization of the adhesive bond line is needed to predict failure modes and fracture toughness. In this paper, bond line thickness was estimated from data obtained using through transmission flash thermography. The forward model that predicts back surface temperature is based on a three layer heat diffusion equation with varying diffusivity and flux boundary conditions. The corresponding inverse problem of estimating bond line thickness from measurement data was solved using a Bayesian approach that assumed Gaussian priors for the bond line thickness and thermal diffusivity of the adherends. Finally, the outputs of the thermography based method were compared to measurements that were collected using a micrometer and ultrasound testing.

Flash thermography↗

Laser Angle of Incidence Effects on in-Situ Consolidation of Automated Fiber Placement of Polyaryletherketone Composites

NASA and Electroimpact, Inc. ®†† in conjunction with other U.S. industry partners are performing research as a part of the NASA High-rate Composites for Aircraft Manufacturing (HiCAM) Project to fabricate thermoplastic panels using automated fiber placement (AFP) to increase manufacturing rates of aircraft structural composites. This work focuses on evaluating the in-situ consolidation AFP of thermoplastics (ICAT) process. Previous studies of the ICAT process using semi-crystalline, polyaryletherketone (PAEK) slit-tape have resulted in an adequate degree of intimate contact between plies; however, the resulting interlaminar strength have been less than laminates fabricated in an autoclave. To improve these properties, the effect of reducing the laser angle of incidence (AoI) during placement to increase the degree of auto-hesion was evaluated. The AoI of the laser assisted AFP head was varied between 12° and 16° to fabricate multiple quasi- isotropic and unidirectional test panels. Physics-based thermal models developed at the NASA Langley Research Center were utilized to predict the temperature profile. Laminate processing temperature was measured experimentally, and panel quality was evaluated by both non- destructive evaluation (NDE) as well as destructively by photo-microscopy. The effect on interlaminar strength was determined by short beam strength testing. Test results of carbon fiber laminates fabricated by ICAT using polyetheretherketone (PEEK), polyetherketoneketone (PEKK), and low-melt polyaryletherketone (LM-PAEK) at various laser angles of incidence, placement temperatures and placement speeds are presented.

Laser↗

Thermal Modelling of the in-Situ Consolidation of Automated Fiber Placement of Thermoplastic Composites

NASA is developing carbon fiber reinforced thermoplastic composites processing methods under the Hi-rate Composites Aircraft Manufacturing (HiCAM) project. The in-situ consolidation automated fiber placement (AFP) of thermoplastics (ICAT) process has high potential to increase manufacturing throughput and lower costs as it combines the repeatability and fast lay down rates of AFP with the thermoformability of thermoplastic materials to achieve part consolidation out of the autoclave. Physics-based process models are employed in the ICAT process development to understand, fundamentally, the thermal response of the carbon fiber (CF)/polyaryletherketone (PAEK) material during the rapid heating and cooling associated with laser-assisted AFP. A one-dimensional (1-D) closed-form model was developed capable of predicting the temperature profile through-the-thickness of the tape material. In addition, a two-dimensional (2-D) model was developed to predict the heat transfer through-the-thickness and in the laydown x-direction of the AFP head motion. The solution of the Fourier heat-transfer equations in the 2-D model is approximated using the explicit finite difference numerical method. The temperature profile during placement of PAEK slit-tape materials at various laser target temperatures and placement speeds were measured during ICAT process development trials at Electroimpact®, Inc. †† and the resulting experimental data is compared with the predictions of the 1-D and 2-D models.

Thermoplastics↗