Search NASA⌕ Search

Engineering topics

Uchida, Y

Publications and source records attributed to Uchida, Y.

Development of a Data Overflow Protection System for Super-Kamiokande to Maximize Data from Nearby Supernovae

Neutrinos from very nearby supernovae, such as Betelgeuse, are expected to generate more than ten million events over 10 s in Super-Kamokande (SK). At such large event rates, the buffers of the SK analog-to-digital conversion board (QBEE) will overflow, causing random loss of data that are critical for understanding the dynamics of the supernova explosion mechanism. In order to solve this problem, two new data-acquisition (DAQ) modules were developed to aid in the observation of very nearby supernovae. The first of these, the SN module, is designed to save only the number of hit photomultiplier tubes during a supernova burst and the second, the Veto module, prescales the high-rate neutrino events to prevent the QBEE from overflowing based on information from the SN module. In the event of a very nearby supernova, these modules allow SK to reconstruct the time evolution of the neutrino event rate from beginning to end using both QBEE and SN module data. This paper presents the development and testing of these modules together with an analysis of supernova-like data generated with a flashing laser diode. We demonstrate that the Veto module successfully prevents DAQ overflows for Betelgeuse-like supernovae as well as the long-term stability of the new modules. During normal running the Veto module is found to issue DAQ vetos a few times per month resulting in a total dead-time less than 1 ms, and does not influence ordinary operations. Additionally, using simulation data we find that supernovae closer than 800 pc will trigger the Veto module, resulting in a prescaling of the observed neutrino data.

F20 Instrumentation and technique↗

SU-F-T-396: Impact of Shoulder Deformation for Head and Neck VMAT

Purpose: For head and neck VMAT (HN-VMAT), variations of position and deformation of patient’s shoulders is a concern to affect inaccuracy of dose distribution. It has been reported that the setup error of the shoulders was variable from 5 mm – 1 cm. The beams of the HN-VMAT pass through the shoulders. We assessed the impact of shoulder deformation to dose distribution for HN-VMAT. Methods: One HN-VMAT plan was generated using a patient’s CT. The patient’s CT was deformed using ImSimQA (Oncology Systems Limited, Shrewsbury, Shropshire, UK) to generate several patterns of the shoulders’ deformations when the right and left humeral heads were shifted with 3, 6, and 15 mm in the superior and inferior directions (SI), 3, 5, and 15 mm in the anterior and posterior directions (AP), and 5 and 15 mm in the right or left direction (LR). DVH comparison was performed in the different deformation patterns. The dosimetric parameters of D95% for CTV70Gy, CTV60Gy and CTV54Gy and dmax for Spinal cord were also measured. Gamma index evaluation (Criteria: 3%/2mm) was performed to exhibit clinically tolerable area in the comparison. Results: DVH comparison shows similar for all structures. As the comparison for the dosimetric parameters, the variations of D95% in the LR and AP were within 1%. There were larger variations in the SI than those in the other directions, however were within 1.5%. In gamma index evaluation, the small spots with higher gamma index values were appeared when the shift was 6 mm, however the pass ratio was 99.13%. Conclusion: HN-VMAT should be robust for shoulder deformation and geometric accuracy within 6 mm from patient’s setup and image-guided radiotherapy may be clinically acceptable for target dose coverage or normal tissue dose sparing.

60 APPLIED LIFE SCIENCES↗

SU-F-T-494: A Multi-Institutional Study of Independent Dose Verification Using Golden Beam Data

Purpose: In general, beam data of individual linac is measured for independent dose verification software program and the verification is performed as a secondary check. In this study, independent dose verification using golden beam data was compared to that using individual linac’s beam data. Methods: Six institutions were participated and three different beam data were prepared. The one was individual measured data (Original Beam Data, OBD) .The others were generated by all measurements from same linac model (Model-GBD) and all linac models (All-GBD). The three different beam data were registered to the independent verification software program for each institute. Subsequently, patient’s plans in eight sites (brain, head and neck, lung, esophagus, breast, abdomen, pelvis and bone) were analyzed using the verification program to compare doses calculated using the three different beam data. Results: 1116 plans were collected from six institutes. Compared to using the OBD, the results shows the variation using the Model-GBD based calculation and the All-GBD was 0.0 ± 0.3% and 0.0 ± 0.6%, respectively. The maximum variations were 1.2% and 2.3%, respectively. The plans with the variation over 1% shows the reference points were located away from the central axis with/without physical wedge. Conclusion: The confidence limit (2SD) using the Model-GBD and the All-GBD was within 0.6% and 1.2%, respectively. Thus, the use of golden beam data may be feasible for independent verification. In addition to it, the verification using golden beam data provide quality assurance of planning from the view of audit. This research is partially supported by Japan Agency for Medical Research and Development(AMED)

60 APPLIED LIFE SCIENCES↗

Effect of Minor Alloying Element on Dispersing Nano-particles in ODS Steel

From the irradiation resistance and high-temperature strength, oxide dispersion strengthened (ODS) ferritic steels are candidate materials for advanced and fusion reactors. For the development of advanced steels the key issue is to homogenize nano-particles into matrix. Recent studies have indicated that Ti addition can homogenize Y-Ti complex particles into ferrite matrix, but the reason of the effect of additional elements has not been clarified. In this model study, we focus on the effect of additional elements, such as IV and V families and other oxide formers, which can control potentially the distribution of the oxide particles. The materials used in this study were based on Fe-9Cr-Y{sub 2}O{sub 3} alloys which were mechanical alloyed (MA) from the powder of Fe, Cr and Y{sub 2}O{sub 3}, which was added systematically with the element of Ti, Zr, Ta, V, Nb, Hf, Al, Si and others. Usually ODS fabrication process is required for hot extrusion, but we annealed up to 1150 C for simplify the microstructure. To evaluate the distribution of ODS particles; we used TEM equipped with EDS after electro-polishing or FIB techniques. (1) In the case of Si or Al addition, oxides were disappeared after MA process, which means Y{sub 2}O{sub 3} and other elements should be in solution at non-equilibrium condition. Two types of oxides of Y{sub 2}O{sub 3} and Al{sub 2}O{sub 3} or SiO{sub 2} developed after the annealing at 850 C, but only complex oxides were developed after the annealing at 1150 C. This result suggests that the oxide formation is independent process for Y and Si or Al. (2) In the case of Ti addition, oxides also were disappeared after MA process, but developed after annealing at 1150 C. This means that Ti can stabilize complex oxides of Y and Ti, and enhance the fine distribution of the oxides comparing with simple Fe-9Cr-Y{sub 2}O{sub 3} alloy. (authors)

36 MATERIALS SCIENCE↗

Search for B{sup 0}{yields}{lambda}{sub c}{sup +}{lambda}{sub c}{sup -} decay at Belle

We search for the doubly charmed baryonic decay B{sup 0}{yields}{lambda}{sub c}{sup +}{lambda}{sub c}{sup -}, in a data sample of 520x10{sup 6} BB events accumulated at the {upsilon}(4S) resonance with the Belle detector at the KEKB asymmetric-energy e{sup +}e{sup -} collider. We find no significant signal and set an upper limit of B(B{sup 0}{yields}{lambda}{sub c}{sup +}{lambda}{sub c}{sup -})<6.2x10{sup -5} at 90% confidence level. The result is significantly below a naive extrapolation from B(B{sup -}{yields}{xi}{sub c}{sup 0}{lambda}{sub c}{sup -}) assuming a simple Cabibbo-suppression factor of |V{sub cd}/V{sub cs}|{sup 2}. The small branching fraction may be attributed to a suppression due to the large momentum of the baryonic decay products, which has been observed in other charmed baryonic two-body B decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗