Search NASA⌕ Search

Engineering topics

Uddin, Nezam

Publications and source records attributed to Uddin, Nezam.

Fabrication of silicon-tipped fiber-optic temperature sensors using aerogel-assisted glass soldering with precise laser heating

We demonstrate the fabrication of fiber-optic Fabry–Perot interferometer (FPI) temperature sensors by bonding a small silicon diaphragm to the tip of an optical fiber using low melting point glass powders heated by a 980 nm laser on an aerogel substrate. The heating laser is delivered to the silicon FPI using an optical fiber, while the silicon temperature is being monitored using a 1550 nm white-light system, providing localized heating with precise temperature control. The use of an aerogel substrate greatly improves the heating efficiency by reducing the thermal loss of the bonding parts to the ambient environment. A desirable temperature for bonding can be achieved with relatively small heating laser power. The bonding process is carried out in an open space at room temperature for convenient optical alignment. The precise temperature control ensures minimum perturbation to the optical alignment and no induced thermal damage to the optical parts during the bonding process. For demonstration, we fabricated a low-finesse and high-finesse silicon FPI sensor and characterized their measurement resolution and temperature capability. The results show that the fabrication method has a good potential for high-precision fabrication of fiber-optic sensors.

Sheng, Qiwen↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗

Fiber-optic silicon Fabry–Perot interferometric bolometer with improved detection limit for magnetic confinement fusion

Fiber-optic bolometers (FOBs) intended for plasma radiation measurement in magnetically confined fusion have been previously developed using a silicon pillar that functions as both a Fabry–Perot interferometer (FPI) for temperature measurement and an absorber for the radiation. We report an FOB design that can significantly improve the detection sensitivity over earlier designs by engineering the absorber of the FOB. Our design uses the fact that, compared with a silicon pillar, a gold film with the same x-ray absorption thickness will show a much higher temperature rise from a given power density of the radiation. Therefore, the responsivity of an FOB can be improved by attaching a large gold disk to the silicon FPI as the absorber. We have developed a fabrication method for FOBs of such design and obtained an FOB with a 4-µm-thick, 0.6-mm-diameter gold disk attached to a 200-µm-diameter, 100-µm-thick silicon FPI. We have characterized the noise, responsivity, response time, and noise-equivalent power density (NEPD) and compared these with the earlier design where the absorber is mainly the silicon FPI itself. The experimental result suggests that the FOB with the gold disk achieves a responsivity of ∼2.8 mK/(W/m2) and a noise-equivalent-power-density of 0.13 W/m2, which are, respectively, more than nine times larger and six times smaller compared to the FOB using a previous design. Improved NEPD and good absorption over a broad frequency range will make the FOB more attractive for applications in magnetic-confinement fusion devices.

Uddin, Nezam↗

Fiber-Optic Silicon Fabry-Perot Interferometric Bolometer: The Influence of Mechanical Vibration and Magnetic Field

Plasma radiation plays an important role in the operation and control of magnetic confinement fusion and is typically measured by bolometers. Here, we study the influence of mechanical vibration and magnetic field, which are typically present in magnetic confinement fusion devices, on the performance of a fiber-optic bolometer (FOB) based on silicon Fabry-Perot interferometer (FPI) demodulated by a scanning diode laser. It is found that both the vibration and magnetic field could cause large noise due to the birefringence of the silicon FPI. To mitigate the birefringence effects, we demonstrated two effective methods: polarization maintaining FOB and polarization scrambling. We show that two methods can be effective in mitigating the effect caused by the sensor birefringence: (1) replacing the regular single-mode fiber in the FOB system with polarization-maintaining fiber and (2) using a polarization scrambler after the laser source. For both methods, no significant increase in the noise was observed in the vibration and magnetic field tests. Finally, our research highlights the importance of the polarization management for the FOB systems toward their practical applications in magnetic-confinement fusion systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗