Search NASA⌕ Search

Engineering topics

Ueki, Ryuichi

Publications and source records attributed to Ueki, Ryuichi.

Collimator challenges at SuperKEKB and their countermeasures using nonlinear collimator

In SuperKEKB, movable collimators reduce the beam background noise in the Belle II particle detector and protect crucial machine components, such as final focusing superconducting quadrupole magnets (QCS), from abnormal beam losses. The challenges related to the collimator, which were not properly considered at the time of SuperKEKB design, have surfaced through experience with its operation. In this paper, we report the collimator operation strategy in SuperKEKB. In addition, a significant challenge of beam collimation due to the future increase in the beam background is highlighted. We also discuss another issue caused by unexpected and sudden beam losses in the machine that damage collimators, leading to weaker beam collimation performance and an increase in transverse impedance. Furthermore, we introduce a novel collimation approach called the nonlinear collimator (NLC) to address these challenges. We detail the concept of NLC and evaluate their effectiveness by assessing the collimator impedance, beam background reduction, and impact on the dynamic aperture. The possibility of using NLCs as absorber collimators to counteract events that damage the collimator is also shown to be helpful.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of quenching-induced magnetic flux trapping using a magnetic field and temperature mapping system

Highly efficient superconducting radio-frequency cavities exhibit low heat loss and are used as components in accelerators and superconducting devices due to their high Q-values. The precise location of magnetic flux trapping in cavities is necessary to identify its effects on the performance of superconducting cavities. In this study, we report a new combined mapping system to measure the temperature and magnetic field on the equator. The proposed system comprehensively maps local magnetic field changes as magnetic flux trapping due to quenching. Our experimental results show that magnetic flux trapping due to quenching increases the local surface resistance of superconducting cavities at 2 K. Thus, the proposed system elucidates the relationship between local flux trapping due to quenching and surface resistance in superconducting cavities and highlights the effect of quenching on the surface resistance. This system can aid in the development of superconducting cavities with higher Q values.

43 PARTICLE ACCELERATORS↗

Systematic evaluation of magnetic sensitivities of anisotropic magnetoresistive sensors at liquid helium temperature for superconducting cavities

Trapped magnetic flux in bulk superconductors reduces the quality factor Q in superconducting radio-frequency (SRF) cavities. However, the mechanisms underlying flux trapping and radio-frequency loss are not well understood. Detailed observation of the magnetic distributions is important for understanding such phenomena. Magnetic field mapping is useful for observing the magnetic field distribution around SRF cavities. Measuring the change in the magnetic field around the cavity elucidates the flux trapping behavior. Anisotropic magnetoresistive (AMR) sensors are inexpensive and small devices that can detect magnetic flux density. The magnetic sensitivities of AMR sensors need to be evaluated at liquid helium temperature for the magnetic field mapping of SRF cavities. In this study, a test stand was constructed to calibrate the magnetic sensitivities of AMR sensors in liquid helium, and 110 AMR sensors were tested using this stand. The magnetic sensitivities were evaluated systematically. A solenoid coil was used to control the uniform external magnetic field and to measure the magnetic sensitivity at low temperatures. All AMR sensors exhibited suitable sensitivities to the magnetic field around the SRF cavity. The variation in these sensitivities in all AMR sensors was ~1%. Further, the AMR sensors were found to have sufficient sensitivity for mapping the magnetic field around the exterior surface of the SRF cavity.

43 PARTICLE ACCELERATORS↗