Search NASASearch

Engineering topics

Underwood, M. L.

Publications and source records attributed to Underwood, M. L..

At least 19 records

Sodium Transport Modes in AMTEC Electrodes

Transport of alkali metal atoms through porous cathodes of alkali metal thermal-to-electric converter (AMTEC) cells is responsible for significant, reducible losses in the electrical performance of these cells.

Sodium

Directly Deposited Current Collecting Grids for Alkali Metal Thermal-to-Electric Converter Electrodes

Current collection in porous thin film electrodes on solid electrolytes has been improved by using thick film grids to decrease sheet and contact resistance in RhW and PtW electrodes. The grids are directly deposited on the solid electrolyte either by sputter- or photodeposition, and the electrode deposited over the grid. Comparison of the performance of electrodes having such underlying grids with that of electrodes without such grids has shown performance, as measured by current or power produced, to be improved by 10-30% in electrodes with grids.

Ryan, M. A.

Directly Deposited Current Collecting Grids for AMTEC Electrodes

Current collection in porous thin film electrodes on solid electrolytes has been improved by using thick film grids to decrease sheet and contact resistance in RhW and PtW electrodes. The grids are directly deposited on the solid electrolyte, either by sputter or photodepostion, and the electrode is deposited over the grid. Comparison of the performance of electrodes having such underlying grids with that of electodes without such grids has shown performance, as measured by current or power produced, to be improved by 10-30% in electrodes with grids.

Ryan, M. A.

(abstract) Fundamental Mechanisms of Electrode Kinetics and Alkali Metal Atom Transport at the Alkali Beta'-Alumina/Porous Electrode/Alkali Metal Vapor Three Phase Boundary

The mechanisms of electrode kinetics and mass transport of alkali metal oxidation and alkali metal cation reduction at the solid electrolyte/porous electrode boundary as well as alkali metal transport through porous metal electrodes has important applications in optimizing device performance in alkali metal thermal to electric converter (AMTEC) cells which are high temperature, high current density electrochemical cells. Basic studies of these processes also affords the opportunity to investigate a very basic electrochemical reaction over a wide range of conditions; and a variety of mass transport modes at high temperatures via electrochemical techniques. The temperature range of these investigations covers 700K to 1240K; the alkali metal vapor pressures range from about 10(sup -2) to 10(sup 2) Pa; and electrodes studied have included Mo, W, Mo/Na(sub 2)MoO(sub 4), W/Na(sub 2)WO(sub 4), WPt(sub x), and WRh(sub x) (1.0 < x < 6.0 ) with Na at Na-beta'-alumina, and Mo with K at K-beta'-alumina. Both liquid metal/solid electrolyte/alkali metal vapor and alkali metal vapor/solid electrolyte/vapor cells have been used to characterize the reaction and transport processes. We have previously reported evidence of ionic, free molecular flow, and surface transport of sodium in several types of AMTEC electrodes.

electrode kinetics thermal to electric conversion

(abstract) Alkali Metal Diffusion Through Porous Metal Electrodes in AMTEC Cells

The mechanisms of mass transport of an alkali metal through porous metal electrodes in alkali metal thermal-to-electric converter AMTEC cells is important in optimizing these high current density devices, but also affords the opportunity to investigate a variety of simple mass transport modes at high temperatures via electrochemical techniques. We have previously reported evidence of ionic, free molecular flow, and surface transport of sodium in several types of AMTEC electrodes. Quantitative investigations of Na transport through WPt(sub 3.5) via surface or grain boundary diffusion, and K transport through porous Mo electrodes by free molecular flow, over large ranges of temperature have been performed. WPt(sub 3.5) has especially low transport impedance over the 950 to 1200K temperature range. New results are the Na through porous WPt(sub 3.5) and K through porous Mo diffusion rates and mechanisms.

alkali metal mass transport porous metal electrode

(abstract) Experimental and Modeling Studies of the Exchange Current at the Alkali Beta'-Alumina/Porous Electrode/Alkali Metal Vapor Three Phase Boundary

The microscopic mechanism of the alkali ion-electron recombination reaction at the three phase boundary zone formed by a porous metal electrode in the alkali vapor on the surface of an alkali beta'-alumina solid electrolyte (BASE) ceramic has been studied by comparison of the expected rates for the three simplest reaction mechanisms with known temperature dependent rate data; and the physical parameters of typical porous metal electrode/BASE/alkali metal vapor reaction zones. The three simplest reactions are tunneling of electrons from the alkali coated electrode to a surface bound alkali metal ion; emission of an electron from the electrode with subsequent capture by a surface bound alkali metal ion; and thermal emission of an alkali cation from the BASE and its capture on the porous metal electrode surface where it may recombine with an electron. Only the first reaction adequately accounts for both the high observed rate and its temperature dependence. New results include crude modeling of simple, one step, three phase, solid/solid/gas electrochemical reaction.

conversion

Advances in Studies of Electrode Kinetics and Mass Transport in AMTEC Cells (abstract)

Previous work reported from JPL has included characterization of electrode kinetics and alkali atom transport from electrodes including Mo, W, WRh(sub x), WPt(sub x)(Mn), in sodium AMTEC cells and vapor exposure cells, and Mo in potassium vapor exposure cells. These studies were generally performed in cells with small area electrodes (about 1 to 5 cm(sup 2)), and device geometry had little effect on transport. Alkali diffusion coefficients through these electrodes have been characterized, and approximate surface diffusion coefficients derived in cases of activated transport. A basic model of electrode kinetic at the alkali metal vapor/porous metal electrode/alkali beta'-alumina solid electrolyte three phase boundary has been proposed which accounts for electrochemical reaction rates with a collision frequency near the three phase boundary and tunneling from the porous electrode partially covered with adsorbed alkali metal atoms. The small electrode effect in AMTEC cells has been discussed in several papers, but quantitative investigations have described only the overall effect and the important contribution of electrolyte resistance. The quantitative characterization of transport losses in cells with large area electrodes has been limited to simulations of large area electrode effects, or characterization of transport losses from large area electrodes with significant longitudinal temperature gradients. This paper describes new investigations of electrochemical kinetics and transport, particularily with WPt(sub 3.5) electrodes, including the influence of electrode size on the mass transport loss in the AMTEC cell. These electrodes possess excellent sodium transport properties making verification of device limitations on transport much more readily attained.

electrode kinetics alkali atom transport transport

Component Selection, Accelerated Testing, and Improved Modeling of AMTEC Systems for Space Power (abstract)

Alkali metal thermal to electric converter (AMTEC) designs for space power are numerous, but selection of materials for construction of long-lived AMTEC devices has been limited to electrodes, current collectors, and the solid electrolyte. AMTEC devices with lifetimes greater than 5 years require careful selection and life testing of all hot-side components. The likely selection of a remote condensed design for initial flight test and probable use with a GPHS in AMTEC powered outer planet probes requires the device to be constructed to tolerate T greater than 1150K, as well as exposure to Na(sub (g)), and Na(sub (liq)) on the high pressure side. The temperatures involved make critical high strength and chemical resistance to Na containing Na(sub 2)O. Selection among materials which can be worked should not be driven by ease of fabricability, as high temperature stability is the critical issue. These concepts drive the selection of Mo alloys for Na(sub (liq)) containment in AMTEC cells for T to 1150K operation, as they are significantly stronger than comparable NB or Ta alloys, are less soluble in Na(sub (liq)) containing dissolved Na(sub 2)O, are workable compared to W alloys (which might be used for certain components), and are ductile at the T greater than 500K of proposed AMTEC modules in space applications.

AMTEC thermal to electric conversion

Electrode performance parameters for a radioisotope-powered AMTEC for space power applications

The alkali metal thermoelastic converter (AMTEC) is a device for the direct conversion of heat to electricity. Recently a design of an AMTEC using a radioisotope heat source was described, but the optimum condenser temperature was hotter than the temperatures used in the laboratory to develop the electrode performance model. Now laboratory experiments have confirmed the dependence of two model parameters over a broader range of condenser and electrode temperatures for two candidate electrode compositions. One parameter, the electrochemical exchange current density at the reaction interface, is independent of the condenser temperature, and depends only upon the collision rate of sodium at the reaction zone. The second parameter, a morphological parameter, which measures the mass transport resistance through the electrode, is independent of condenser and electrode temperatures for molybdenum electrodes. For rhodium-tungsten electrodes, however, this parameter increases for decreasing electrode temperature, indicating an activated mass transport mechanism such as surface diffusion.

Underwood, M. L.

Advances in materials and current collecting networks for AMTEC electrodes

Electrode materials for the Alkali Metal Thermal to Electric Converter (AMTEC) play a significant role in the efficiency of the device. RhW and PtW alloys have been studied to determine the best performing material. While RhW electrodes typically have power densities somewhat lower than PtW electrodes, PtW performance is strongly influenced by the Pt/W ratio. The best performing Pt/W ratio is about 3.4. RhW electrodes sinter more slowly than PtW and are predicted to have operating lifetimes up to 40 years; PtW electrodes are predicted to have lifetimes up to 7 years. Interaction with the current collection network can significantly decrease lifetime by inducing metal migration and segregation and by accelerating the sintering rate.

Ryan, M. A.

Activated transport in AMTEC electrodes

Transport of alkali, metal atoms through porous cathodes of alkali metal thermal-to-electric converter (AMTEC) cells is responsible for significant reducible losses in the electrical performance of these cells. Experimental evidence for activated transport of metal atoms at grain surfaces and boundaries within some AMTEC electrodes has been derived from temperature dependent studies as well as from analysis of the detailed frequency dependence of ac impedance results for other electrodes, including thin, mature molybdenum electrodes which exhibit transport dominated by free molecular flow of sodium gas at low frequencies or dc conditions. Activated surface transport will almost always exist in parallel with free molecular flow transport, and the process of alkali atom adsorption/desorption from the electrode surface will invariably be part of the transport process, and possibly a dominant part in some cases. The temperature dependence of the diffusion coefficient of the alkali metal through the electrode in several cases provides an activation energy and preexponential, but at least two activated processes may be operative, and the activation parameters should be expected to depend on the alkali metal activity gradient that the electrode experiences. In the case of Pt/W/Mn electrodes operated for 2500 hours, limiting currents varied with electrode thickness, and the activation parameters could be assigned primarily to the surface/grain boundary diffusion process.

Williams, R. M.

Efficiency of an AMTEC recirculating test cell, experiments and projections

The alkali metal thermal to electric converter (AMTEC) is an electrochemical device for the direct conversion of heat to electrical energy with efficiencies potentially near Carnot. The future usefulness of AMTEC for space power conversion depends on the efficiency of the devices. Systems studies have projected from 15 to 35 percent thermal to electric conversion efficiencies, and one experiment has demonstrated 19 percent efficiency for a short period of time. Recent experiments in a recirculating test cell (RTC) have demonstrated sustained conversion efficiencies as high as 10.2 percent early in cell life and 9.7 percent after maturity. Extensive thermal and electrochemical analysis of the cell during several experiments demonstrated that the efficiency could be improved in two ways. First, the electrode performance could be improved. The electrode for these tests operated at about one third the power density of state of the art electrodes. The low power density was caused by a combination of high series resistance and high mass flow resistance. Reducing these resistances could improve the efficiency to greater than 10 percent. Second, the cell thermal performance could be improved. Efficiencies greater than 14 percent could be realized through reducing the radiative thermal loss. Further improvements to the efficiency range predicted by systems studies can be accomplished through the development and use of an advanced condenser with improved reflectivity, close to that of a smooth sodium film, and the series connecting of individual cells to further reduce thermal losses.

Underwood, M. L.

Assessment of the US industrial program for AMTEC development

The Alkali Metal Thermal to Electric Converter (AMTEC) is a static energy conversion technology that is expected to provide low mass thermal to electric conversion with efficiencies between 20 and 35 percent. The U.S. program to develop this technology for space power applications has grown substantially over the past 3 years. This expanding program has brought together several laboratories and technical consultants, in separately sponsored projects, to develop the key elements of the technology. An assessment of this multiparty program indicates that, in general, the effort has focused on the high priority technical elements with only moderate overlap between individual projects. There are, however, several areas where additional coordination is needed between major participants in the existing projects, and other areas where new projects should be started, in order to provide reliable space power systems without unnecessary delays.

Sievers, R. K.

Thermal modelling of an AMTEC recirculating cell

A modeling program was developed to determine the impact of various design parameters on the operation of an AMTEC system. Temperature profiles generated by the modeling program were compared to actual experimental data to verify the model accuracy. The model was then extended to predict the impact of device design on operational performance. The effect of heat loss from the liquid sodium supply end was studied for this paper.

Suitor, J. W.