Search NASA⌕ Search

Engineering topics

Ungaro, Maurizio

Publications and source records attributed to Ungaro, Maurizio.

Geant4 Monte-Carlo (GEMC) A database-driven simulation program

GEMC[1] is an application that harnesses the power of databases to execute Geant4 Monte-Carlo simulations. The databases (MYSQL, CSQL, TEXT) define the geometry, materials, digitization algorithms, readout electronics and output formats. Implemented in C++, GEMC also boasts a user-friendly Python API that facilitates detector construction and database population. GEMC can handle real-life scenarios such as geometry variations and the run number-dependent calibration constants and digitization parameters. This abstract provides an overview of GEMC, accompanied by examples that showcase its versatility. We delve into the practical application of GEMC within the the CLAS12 experimental program at Jefferson Lab.

Ungaro, Maurizio↗

CLAS12 simulations on OSG

An overview of the latest updates of CLAS12 simulation software GEMC and running on the Open Science Grid will be shown. A tutorial will be shown.

Ungaro, Maurizio↗

Streaming readout for next generation electron scattering experiments

Current and future experiments at the high-intensity frontier are expected to produce an enormous amount of data that needs to be collected and stored for offline analysis. Thanks to the continuous progress in computing and networking technology, it is now possible to replace the standard ‘triggered’ data acquisition systems with a new, simplified and outperforming scheme. ‘Streaming readout’ (SRO) DAQ aims to replace the hardware-based trigger with a much more powerful and flexible software-based one, that considers the whole detector information for efficient real-time data tagging and selection. Considering the crucial role of DAQ in an experiment, validation with on-field tests is required to demonstrate SRO performance. In this paper, we report results of the on-beam validation of the Jefferson Lab SRO framework. In this work, we exposed different detectors (PbWO-based electromagnetic calorimeters and a plastic scintillator hodoscope) to the Hall-D electron-positron secondary beam and to the Hall-B production electron beam, with increasingly complex experimental conditions. By comparing the data collected with the SRO system against the traditional DAQ, we demonstrate that the SRO performs as expected. Furthermore, we provide evidence of its superiority in implementing sophisticated AI-supported algorithms for real-time data analysis and reconstruction.

47 OTHER INSTRUMENTATION↗

Enhanced UV light detection using a p-terphenyl wavelength shifter

Here, UV-glass photomultiplier tubes (PMTs) have poor photon detection efficiency for wavelengths below $300\,\text{nm}$ due to the opaqueness of the window material. Costly quartz PMTs could be used to enhance the efficiency below $300\,\text{nm}$. A less expensive solution that dramatically improves this efficiency is the application of a thin film of a p-terphenyl (PT) wavelength shifter on UV-glass PMTs. This improvement was quantified for Photonis XP4500B PMTs for wavelengths between $200\,\text{nm}$ and $400\,\text{nm}$. The gain factor ranges up to 5.4 $\pm$ 0.5 at a wavelength of $215\,\text{nm}$, with a material load of $110\pm10\,\mu\text{g}/\text{cm}^2$ ($894\,\text{nm}$). The wavelength shifter was found to be fully transparent for wavelengths greater than $300\,\text{nm}$. The resulting gain in detection efficiency, when used in a typical Cherenkov counter, was estimated to be of the order of 40%. Consistent coating quality was assured by a rapid gain testing procedure using narrow-band UV LEDs. Based on these results, 200 Photonis XP4500B PMTs were treated with PT for the upgraded low-threshold Cherenkov counter (LTCC) to be used in the CEBAF Large Acceptance Spectrometer upgraded detector (CLAS12) at the Thomas Jefferson National Accelerator Facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electroproduction of À0 in the resonance region at high Q2 with CLAS

An extensive program is underway at Jefferson Lab to study the eletromagnetic excitations of baryon states. We report the analysis of exclusive single ?0 electroproduction in the resonance region at Jefferson Lab in the Q2 range of 2 to 6 GeV2/c2. A longitudinally polarized 5.75 GeV electron beam was incident on a 5 cm long liquid Hydrogen target. The CLAS spectrometer at Jefferson Lab was used to detect the final state particles. The data was taken between October 2001 and January 2002. Preliminary results for differential cross sections over the entire 4? c.m. solid angle will be presented. This high precision measurement will allow us to access the structure and dynamics of nucleon excitations with masses up to 2 GeV.

Ungaro, Maurizio↗

PROGRESS ON THE INTERACTION REGION DESIGN AND DETECTOR INTEGRATION AT JLAB'S MEIC

One of the unique features of JLab's Medium-energy Electron-Ion Collider (MEIC) is a full-acceptance detector with a dedicated, small-angle, high-resolution detection system, capable of covering a wide range of momenta (and charge-to-mass ratios) with respect to the original ion beam to enable access to new physics. We present an interaction region design developed with close integration of the detection and beam dynamical aspects. The dynamical aspect of the design rests on a symmetry-based concept for compensation of non-linear effects. The optics and geometry have been optimized to accommodate the detection requirements and to ensure the interaction region's modularity for ease of integration into the collider ring lattices. As a result, the design offers an excellent detector performance combined with the necessary provisions for non-linear dynamical optimization.

Morozov, Vasiliy↗

Beam-spin Asymmetries from Semi-inclusive Pion Electroproduction

We have measured the moment A{sup sin{phi}}{sub LU} corresponding to the polarized electron beam-spin asymmetry in SIDIS. A{sup sin{phi}}{sub LU} is a twist-3 quantity providing information about quark-gluon correlations. Data were taken with the CLAS Spectrometer at Jefferson Lab using a 5.498 GeV longitudinally polarized electron beam and an unpolarized liquid hydrogen target. All three pion channels (pi{sup +}, pi{sup 0} and pi{sup -}) were measured simultaneously over a large range of kinematics within the virtuality range Q{sup 2} ~ 1.0-4.5 GeV{sup 2}. The observable was measured with good statistical precision over a large range of z, P{sub T}, x{sub B}, and Q{sup 2}, which permits comparison with several reaction models. The discussed measurements provide an upgrade in statistics over previous measurements, and serve as the first evidence for the negative sign of the {pi}{sup -} sin{phi} Moment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the CLAS12 Silicon Vertex Tracker modules

For the 12 GeV upgrade, the CLAS12 experiment has designed a Silicon Vertex Tracker (SVT) using single sided microstrip sensors fabricated by Hamamatsu. The sensors have graded angle design to minimize dead areas and a readout pitch of 156{micro}m, with intermediate strip. Double sided SVT module hosts three daisy-chained sensors on each side with a full strip length of 33 cm. There are 512 channels per module read out by four Fermilab Silicon Strip Readout (FSSR2) chips featuring data driven architecture, mounted on a rigid-flex hybrid. Modules are assembled on the barrel using unique cantilevered geometry to minimize the amount of material in the tracking volume. Design and performance of the SVT modules are presented, focusing on results of electrical measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and performance of the Silicon Vertex Tracker modules for the CLAS12 experiment

The Continuous Electron Beam Accelerator Facility's (CEBAF) Large Acceptance Spectrometer (CLAS) is being upgraded for the 12 GeV electron beam. The Silicon Vertex Tracker (SVT) will be part of the Central Tracker for the CLAS12 experiment and will be centered inside of the solenoid, which has 5 T magnetic field. We present the design, fabrication, characterization and performance of the SVT modules.

Gotra, Yuri↗

Beam-spin Asymmetries from Semi-inclusive Pion Electroproduction

The moment of the semi-inclusive deep inelastic scattering (SIDIS) cross section corresponding to a polarized lepton scattering from an unpolarized target is Asin?LU. It has been extracted from measurements of beam-spin asymmetries (BSAs) from pion electro-production in SIDIS. Data were taken with the continuous electron beam accelerator facility (CEBAF) Large Acceptance Spectrometer (CLAS) at Jefferson Lab using a 5.498 GeV longitudinally polarized electron beam and an unpolarized liquid hydrogen target. All three pion channels (?+, ?0 and ??) were measured simultaneously over a large range of kinematics at the intermediate Q2 range (Q2? 1 - 4.5 GeV2). The moment is measured as functions of z, PT, x, and Q2. Asin?LU is a twist-3 structure providing information about quark-gluon-quark correlations. This new high statistical data will provide an important means of studying the transverse degrees of freedom in the nucleon.

Gohn, Wesley↗

Exclusive pi0 electroproduction in the resonance region

We report the analysis of single ?0 electroproduction in the resonance region to study the electromagnetic excitation of the nucleon resonances. The study is aimed at understanding the internal structure and dynamics of the nucleon. The experiment was performed using an unpolarized cryogenic hydrogen target and polarized electron beam with the CLAS detector at Jefferson Lab. The new measurements produce a data base with high statistics and large kinematic coverage for the hadronic invariant mass W up to 1.8 GeV and in the momentum transfer Q2 range of 0.4 - 1.0 (GeV/c)2 with full angular coverage in the Center of Mass system. This data set is currently being analyzed using a Unitary Isobar Model to determine the Q2 dependence of resonance transition amplitudes for several excited states of the nucleon. Preliminary results will be presented.

Markov, Nikolay↗