Search NASA⌕ Search

Engineering topics

Ungut, A.

Publications and source records attributed to Ungut, A..

Droplet sizes and velocities in vaporizing sprays

A pulse height laser Doppler anemometer particle sizing technique has been refined to permit simultaneous particle size and velocity measurements in sprays. The improvements include (1) the use of a specially tailored 'top hat' light distribution, to provide unambiguous particle diameter-signal amplitude relations, (2) the use of back scattered light collection, and (3) the utilization of Mie theory to compute the relations between signal amplitude and particle diameter, in the backscatter mode. Twin-fluid atomized kerosene sprays have been investigated using the new technique. In these sprays distributions have been mapped of mean droplet diameters, droplet size distributions, and the local correlations between droplet diameters and velocities. The data show the variation of spray structure with atomizer input parameters, the preferential vaporization of smaller droplets, and the differing trajectories of the large and small droplets.

Yule, A. J.↗

Comparisons between geometrical optics and Lorenz-Mie theory

Both the Lorenz-Mie and geometrical optics theories are used in calculating the scattered light patterns produced by transparent spherical particles over a wide range of diameters, between 1.0 and 100 microns, and for the range of forward scattering angles from zero to 20 deg. A detailed comparison of the results shows the greater accuracy of the geometrical optics theory in the forward direction. Emphasis is given to the simultaneous sizing and velocimetry of particles by means of pedestal calibration methods.

Ungut, A.↗

Measurement of fuel spray vaporisation by laser techniques

Comparison of fuel spray structures in heated and in cold environments is made by using a new laser tomographic technique and laser anemometry. The tomography technique is shown to give accurate and rapid 'point' measurements of droplet sizes and concentrations. Experimental results show acceleration of droplets to the local gas velocity, preferential vaporisation of the smallest droplets and the dispersion of droplets by the turbulence.

Yule, A. J.↗

Detailed investigation of a vaporising fuel spray. Part 1: Experimental investigation of time averaged spray

A laser tomographic light scattering technique provides rapid and accurate high resolution measurements of droplet sizes, concentrations, and vaporization. Measurements using a computer interfaced thermocouple are presented and it is found that the potential exists for separating gas and liquid temperature measurements and diagnosing local spray density by in situ analysis of the response characteristics of the thermocouple. The thermocouple technique provides a convenient means for measuring mean gas velocity in both hot and cold two phase flows. The experimental spray is axisymmetric and has carefully controlled initial and boundary conditions. The flow is designed to give relatively insignificant transfer of momentum and mass from spray to air flow. The effects of (1) size-dependent droplet dispersion by the turbulence, (2) the initial spatial segregation of droplet sizes during atomization, and (3) the interaction between droplets and coherent large eddies are diagnosed.

Yule, A. J.↗

A laser tomographic investigation of liquid fuel sprays

A light scattering technique is combined with a tomographic transformation to convert line of sight integrated data, measured in sprays, to measurements of droplet size and concentration in volume elements within the spray. The technique is developed and assessed by systematic experiments in axisymmetric sprays generated by twin-fluid atomisers. The good agreement found shows that, provided certain conditions are satisfied by the local spray structure, the technique provides information on spray structure, similar in detail and extent to that derived by photography, but with reduced experimental time. The technique is applied to an investigation of a kerosene spray vaporizing in a hot gas stream.

Yule, A. J.↗

Particle size and velocity measurement in flames by laser anemometer

Simultaneous droplet size and velocity measurements by a particle counting Laser Doppler Anemometer (LDA) in kerosene fuel sprays under burning and non-burning conditions are presented. Particle sizes are derived from pulse height analysis of the mean LDA signals and velocities are simultaneously determined by measuring Doppler shift frequencies. The measurements show that droplet velocity is a function of droplet diameter for burning and non-burning conditions, and spatially averaged size distributions are derived from velocity data. A comparison of results obtained under burning and non-burning conditions show changes in size distribution due to preferential vaporization of small droplets, acceleration due to thermal expansion of gases, and corresponding changes in droplet momentum.

Chigier, N. A.↗

Flame characteristics of a NASA contra swirler module

Results are presented for an investigation of the structure of unconfined propane flames stabilized on a NASA contra-swirl can. General flame characterization, flame visualization by sodium chloride, temperature measurements, combustion products analysis, nitric oxide concentrations, and laser anemometer studies are considered. The results are discussed relative to sodium chloride visualization, temperature distributions, chemical composition of flames, nitric oxide distributions, and velocity distributions. It is shown that unconfined propane-air flames can be stabilized downstream of a NASA contra-swirl can under a wide range of airflow rates and fuel-air ratios. However, on increasing fuel input from the lowest at which flames can be stabilized, a compact recirculation zone-stabilized flame is formed. The effect of confinement on changes in flame shape and structure is determined.

Thompson, D.↗

Simultaneous velocity and particle size measurement in two phase flows by Laser Anemometry

A technique for particle size measurement by using Laser Doppler Anemometry is discussed. An additional gate photomultiplier has been introduced at right angles to the optical axis in order to select only those particles passing through the central region of the measurement control volume. Particle sizing measurements have been made in sprays of glass particles using the modified Laser Anemometry system. Measurements in fuel sprays are also reported and compared with the results obtained by a photographic technique. The application of the particle sizing technique to opaque particles is investigated and suitable optical arrangements are suggested. Light scattering characteristics of Laser Anemometry systems for different optical geometries are calculated to select the optimum optical arrangement for the particle sizing measurements.

Ungut, A.↗

Flame characteristics of a NASA contra swirler module

The structure of unconfined flames stabilized on a NASA contra-swirl can has been examined. The structure depends on reference velocity and fuel-air ratio, and photographic illustrations of representative examples of each flame type are shown. A highly compact flame is obtained over a narrow band of fuel-air ratios, within the total range over which flames may be stabilized, at high reference velocity (27.8 m/s). The compact structure can only be obtained with careful fuel nozzle location. Chemical concentration profiles, temperature profiles and sodium chloride seeding experiments all confirm the visual impression of compactness. A flame with 50% greater fuel throughput has a much less compact structure, which is reflected in lower maximum temperature, much more complex chemical concentration distributions and a more diffuse recirculation boundary as observed by sodium chloride seeding than in the compact flame. Each of these flames has not only an evident axial recirculation core but also a toroidal recirculation region over the bluff region between the inner and outer swirlers. In contrast, laser Doppler velocimetry measurements carried out on a flame with lower reference velocity (5.65 m/s) do not indicate the presence of a secondary recirculation region in this flame.

Thompson, D.↗

Particle size and velocity measurement by laser anemometry

The use of a forward scattering Laser Anemometer system for the measurement of particle diameters larger than the fringe spacing is investigated. A systematic calibration experiment demonstrates a direct relationship between signal amplitude and particle diameter for transparent particles between 30 microns and 240 microns in diameter. A light scattering analysis confirms these measurements and indicates how the range of particles which can be measured using the peak (mean) signal depends on the optical arrangement and particle properties. On the basis of this work a real time Laser Anemometer signal processor is modified so that the peak of the mean of each signal can be measured. A method of correcting data for the effect of particles which do not go through the center of the measurement volume is derived. Good agreement is found between particle size distributions measured in sprays by using the Laser Anemometer and size distributions measured by collecting the particles on a slide and using an image analysis computer.

Yule, A. J.↗