Search NASA⌕ Search

Engineering topics

Unlu, Kenan

Publications and source records attributed to Unlu, Kenan.

Toward the implementation of self-powered, wireless, real-time reactor power sensing

The successful development of real-time, self-powered, wireless reactor power sensing technology would enable key operating parameters of every fuel assembly in a commercial reactor core to be continuously monitored, and potentially be utilized for applications such as closed-loop reactor control. This paper discusses the expansion of successful work on the application of Self Powered Neutron Detectors (SPND) for reactor power monitoring and the wireless transmission of these detector signals using advanced vacuum micro-electronic (VME) transmitter technology developed by Westinghouse in collaboration with the Penn State University Radiation Science and Engineering Center. Results demonstrate that this technology may be successfully applied via long-term testing in the Penn State TRIGA reactor. SPND are inherently slower than, for example, ion chambers due to their dependence on radioactive decay to generate a signal. Additional research developed delay compensation algorithms to accelerate the response of these detectors for use in near-real-time closed-loop reactor control. Initial results indicate that practical signal acceleration can be obtained digitally or with an equivalent analog circuit. Future research will apply an inverse model of the sensor’s balance differential equations to more-effectively accelerate the SPND signal. Use of inverse models will also prove to be adaptive in the sense that time-dependent burn-up of these detectors, due to neutron activation of the detector material, can be modeled and applied in the acceleration algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile D-T Neutron-Generation System for Fast-Neutron Research and Education

In order to stimulate new cutting-edge research and create novel educational tools at the Pennsylvania State University (PSU), the PIs of the project acquired a versatile 14-MeV D-T neutron-generation system. Relatively recent advancements at Lawrence Berkeley National Laboratory (LBNL) have led to the development of high-neutron-output D-T neutron generators. The resulting technology was subsequently licensed to Adelphi Technology, Inc. and 14-MeV D-T neutron-generation systems are currently available with neutron yields up to 10 10 n/sec. Such neutron output has been available previously; however, the existing D-T generators were traditionally million-dollar systems (an example is D711 from Thermo Scientific), thus beyond reach for many users. The Adelphi neutron generators, on the other hand, now provide access to high neutron outputs for a reasonable price. More importantly, the expected lifetime of the D-T system’s tubes is at least 2,000 hours; a factor of two better when compared to D711, with comparable generator-tube replacement cost. Adelphi Technology, the manufacturer of the dual D-T neutron generation system, delivered one 10 8 neutrons/second and one 10 10 neutrons/second D-T generator with two separate control units to PSU.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating bis(2-ethylhexyl) methanediphosphonic acid (H 2 DEH[MDP]) based polymer ligand film (PLF) for plutonium and uranium extraction

This paper describes a new analyte extraction medium called polymer ligand film (PLF) that was developed to rapidly extract radionuclides. PLF is a polymer medium with ligands incorporated in its matrix that selectively and quickly extracts analytes. The main focus of the new technique is to shorten and simplify the procedure for chemically isolating radionuclides for determination through alpha spectroscopy. The PLF system was effective for plutonium and uranium extraction. The PLF was capable of co-extracting or selectively extracting plutonium over uranium depending on the PLF composition. As a result, the PLF and electrodeposited samples had similar alpha spectra resolutions.

36 MATERIALS SCIENCE↗

The Multi-Isotope Process (MIP) Monitor Project: FY13 Final Report

The Multi-Isotope Process (MIP) Monitor provides an efficient approach to monitoring the process conditions in reprocessing facilities in support of the goal of “… (minimization of) the risks of nuclear proliferation and terrorism.” The MIP Monitor measures the distribution of the radioactive isotopes in product and waste streams of a nuclear reprocessing facility. These isotopes are monitored online by gamma spectrometry and compared, in near-real-time, to spectral patterns representing “normal” process conditions using multivariate analysis and pattern recognition algorithms. The combination of multivariate analysis and gamma spectroscopy allows us to detect small changes in the gamma spectrum, which may indicate changes in process conditions. By targeting multiple gamma-emitting indicator isotopes, the MIP Monitor approach is compatible with the use of small, portable, relatively high-resolution gamma detectors that may be easily deployed throughout an existing facility. The automated multivariate analysis can provide a level of data obscurity, giving a built-in information barrier to protect sensitive or proprietary operational data. Proof-of-concept simulations and experiments have been performed in previous years to demonstrate the validity of this tool in a laboratory setting for systems representing aqueous reprocessing facilities. However, pyroprocessing is emerging as an alternative to aqueous reprocessing techniques.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of Innovative Radioactive Isotope Production Techniques at the Pennsylvania State University Radiation Science and Engineering Center

The Penn State Breazeale Nuclear Reactor (PSBR) at the Radiation Science and Engineering Center (RSEC) has produced radioisotopes for research and commercial purposes since 1956. With the rebirth of the radiochemistry education and research program at the RSEC, the Center stands poised to produce a variety of radioisotopes for research and industrial work that is in line with the mission of the DOE Office of Science, Office of Nuclear Physics, Isotope Development and Production Research and Application Program. The RSEC received funding from the Office of Science in 2010 to improve production techniques and develop new capabilities. Under this program, we improved our existing techniques to provide four radioisotopes (Mn-56, Br-82, Na-24, and Ar-41) to researchers and industry in a safe and efficient manner. The RSEC is also working to develop new innovative techniques to provide isotopes in short supply to researchers and others in the scientific community, specifically Cu-64 and Cu-67. Improving our existing radioisotopes production techniques and investigating new and innovative methods are two of the main initiatives of the radiochemistry research program at the RSEC.

07 ISOTOPE AND RADIATION SOURCES↗

Geant4 Model Validation of Compton Suppressed System for Process monitoring of Spent Fuel

Nuclear material accountancy is of continuous concern for the regulatory, safeguards, and verification communities. In particular, spent nuclear fuel reprocessing facilities pose one of the most difficult accountancy challenges: monitoring highly radioactive, fluid sample streams in near real-time. The Multi-Isotope Process monitor will allow for near-real-time indication of process alterations using passive gamma-ray detection coupled with multivariate analysis techniques to guard against potential material diversion or to enhance domestic process monitoring. The Compton continuum from the dominant 661.7 keV 137Cs fission product peak obscures lower energy lines which could be used for spectral and multivariate analysis. Compton suppression may be able to mitigate the challenges posed by the high continuum caused by scattering. A Monte Carlo simulation using the Geant4 toolkit is being developed to predict the expected suppressed spectrum from spent fuel samples to estimate the reduction in the Compton continuum. Despite the lack of timing information between decay events in the particle management of Geant4, encouraging results were recorded utilizing only the information within individual decays without accounting for accidental coincidences. The model has been validated with single and cascade decay emitters in two steps: as an unsuppressed system and with suppression activated. Results of the Geant4 model validation will be presented.

Bender, Sarah↗

The Multi-Isotope Process (MIP) Monitor Project: FY12 Progress and Accomplishments

The Multi-Isotope Process (MIP) Monitor, being developed at Pacific Northwest National Laboratory (PNNL), provides an efficient approach to monitoring the process conditions in reprocessing facilities in support of the goal of "...(minimization of) the risks of nuclear proliferation and terrorism." The MIP Monitor measures distributions of a suite of indicator (radioactive) isotopes present within product and waste streams of a nuclear reprocessing facility. These indicator isotopes are monitored on-line by gamma spectrometry and compared, in near-real-time, to spectral patterns representing "normal" process conditions using multivariate pattern recognition software. The monitor utilizes this multivariate analysis and gamma spectroscopy of reprocessing streams to detect small changes in the gamma spectrum, which may indicate changes in process conditions. Multivariate analysis methods common in chemometrics, such as principal component analysis (PCA) and partial least squares regression (PLS), act as pattern recognition techniques, which can detect small deviations from the expected, nominal condition. By targeting multiple gamma-emitting indicator isotopes, the MIP Monitor approach is compatible with the use of small, portable, relatively high-resolution gamma detectors that may be easily deployed throughout an existing facility. The automated multivariate analysis can provide a level of data obscurity, giving a built-in information barrier to protect sensitive or proprietary operational data. Proof-of-concept simulations and experiments have been performed in previous years to demonstrate the validity of this tool in a laboratory setting. Development of the MIP Monitor approach continues to evaluate the efficacy of the monitor for automated, real-time or near-real-time application. This report details follow-on research and development efforts sponsored by the U.S. Department of Energy Fuel Cycle Research and Development related to the MIP Monitor for fiscal year 2012 (FY12).

fuel characterization↗

Ion Uptake Determination of Dendrochronologically-Dated Trees Using Neutron Activation Analysis

Uptake of metal ions by plan roots is a function of the type and concentration of metal in the soil, the nutrient biochemistry of the plant, and the immediate environment of the root. Uptake of gold (Au) is known to be sensitive to soil pH for many species. Soil acidification due to acid precipitation following volcanic eruptions can dramatically increase Au uptake by trees. Identification of high Au content in tree rings in dendrochronologically-dated, overlapping sequences of trees allows the identification of temporally-conscribed, volcanically-influenced periods of environmental change. Ion uptake, specifically determination of trace amounts of gold, was performed for dendrochronologically-dated tree samples utilizing Neutron Activation Analysis (NAA) technique. The concentration of gold was correlated with known enviironmental changes, e.g. volcanic activities, during historic periods.

54 ENVIRONMENTAL SCIENCES↗

A Case Study to Test Mozaik for Different Optimization Problems

We present four different shape optimization problems based on the existing beam port facility of the Penn State Breazeale Reactor and their results obtained by the modular optimization code package, MOZAIK. Each model problem has a different beam tube configuration with the same optimization goal: to determine an optimal D2O moderator tank shape for the given beam tube arrangement that maximizes the thermal neutron beam intensity at the beam tube exit end. In this study, the power of the automated search process was demonstrated and its capabilities were tested. In addition, the performance of the beam port was analyzed using alternative beam tube arrangements. All alternative arrangements indicate that higher thermal neutron beam intensity can be obtained at the beam tube exit end using a smaller volume of D2O in the system than is used in the existing beam port configuration. Moreover, the results show that MOZAIK is ready for deployment to address shape optimization problems involving radiation transport in nuclear engineering applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron Computed Tomography of Freeze/thaw Phenomena in Polymer Electrolyte Fuel Cells

This report summarizes the final year's progress of the three-year NEER program. The overall objectives of this program were to 1) design and construct a sophisticated hight-resolution neutron computed tomography (NCT) facility, 2) develop novel and sophisticated liquid water and ice quantification analysis software for computed tomography, and 3) apply the advanced software and NCT capability to study liquid and ice distribution in polymer electrolyte fuel cells (PEFCs) under cold-start conditions. These objectives have been accomplished by the research team, enabling a new capability for advanced 3D image quantification with neutron imaging for fuel cell and other applications. The NCT water quantification methodology and software will greatly add to the capabilities of the neutron imaging community, and the quantified liquid water and ice distribution provided by its application to PEFCs will enhance understanding and guide design in the fuel cell community.

30 DIRECT ENERGY CONVERSION↗