Resonant-frequency discharge in a multi-cell radio frequency cavity

We are reporting experimental results on a microwave discharge operating at resonant frequency in a multi-cell radio frequency (RF) accelerator cavity. Although the discharge operated at room temperature, the setup was constructed so that it could be used for plasma generation and processing in fully assembled active superconducting radio-frequency cryo-module. This discharge offers a mechanism for removal of a variety of contaminants, organic or oxide layers, and residual particulates from the interior surface of RF cavities through the interaction of plasma-generated radicals with the cavity walls. We describe resonant RF breakdown conditions and address the issues related to resonant detuning due to sustained multi-cell cavity plasma. We have determined breakdown conditions in the cavity, which was acting as a plasma vessel with distorted cylindrical geometry. We discuss the spectroscopic data taken during plasma removal of contaminants and use them to evaluate plasma parameters, characterize the process, and estimate the volatile contaminant product removal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of high-voltage pulse-slicer unit with variable pulse duration for pulse radiolysis system

A high-voltage pulse-slicer unit with variable pulse duration has been developed and integrated with a 7 MeV linear electron accelerator (LINAC) for pulse radiolysis investigation. The pulse-slicer unit provides switching voltage from 1 kV to 10 kV with rise time better than 5 ns. Two MOSFET based 10 kV switches were configured in differential mode to get variable duration pulses. The high-voltage pulse has been applied to the deflecting plates of the LINAC for slicing of electron beam of 2 {mu}s duration. The duration of the electron beam has been varied from 30 ns to 2 {mu}s with the optimized pulse amplitude of 7 kV to get corresponding radiation doses from 6 Gy to 167 Gy.

43 PARTICLE ACCELERATORS↗

Design of microcontroller based system for automation of streak camera

A microcontroller based system has been developed for automation of the S-20 optical streak camera, which is used as a diagnostic tool to measure ultrafast light phenomenon. An 8 bit MCS family microcontroller is employed to generate all control signals for the streak camera. All biasing voltages required for various electrodes of the tubes are generated using dc-to-dc converters. A high voltage ramp signal is generated through a step generator unit followed by an integrator circuit and is applied to the camera's deflecting plates. The slope of the ramp can be changed by varying values of the capacitor and inductor. A programmable digital delay generator has been developed for synchronization of ramp signal with the optical signal. An independent hardwired interlock circuit has been developed for machine safety. A LABVIEW based graphical user interface has been developed which enables the user to program the settings of the camera and capture the image. The image is displayed with intensity profiles along horizontal and vertical axes. The streak camera was calibrated using nanosecond and femtosecond lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High etching rates of bulk Nb in Ar/Cl{sub 2} microwave discharge

Plasma-based Nb surface treatment provides an excellent opportunity to eliminate surface imperfections and increase the cavity quality factor in important applications such as particle accelerators and cavity quantum electrodynamics, as well as Josephson junctions. In this study, plasma etching of bulk Nb is performed on the surface of disk-shaped samples with the goal of eliminating nonsuperconductive pollutants in the penetration depth region and the mechanically damaged surface layer. The authors have demonstrated that in the microwave glow discharge, an etching rate of 1.5 {mu}m/min can be achieved using Cl{sub 2} as a reactive gas. The influence of plasma parameters such as input power, pressure, and concentration of the reactive gas on the etching rate is determined. Simultaneously, plasma emission spectroscopy was used to estimate the densities of Cl, Cl{sup +}, and Cl{sub 2} under various plasma conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A high voltage programmable ramp generator

In this paper, a ramp generator with programmable slope is presented. It consists of a high voltage step generator, followed by integrator. The capacitor and inductor in the integrator are designed such that they can be varied by a microcontroller. This circuit generates two bipolar ramps with fastest speed <1 ns and provides continuous speed variation from 6 to 30 ns for a ramp of 500 V. This is being developed as a part of automated streak camera for deflection of electron beam.