Search NASA⌕ Search

Engineering topics

Uplegger, L.

Publications and source records attributed to Uplegger, L..

At least 19 records

Performance Analysis of Phase 2 Tracker Upgrade PS Module Before and After Irradiation

The Large Hadron Collider will undergo a luminosity upgrade targeting a peak instantaneous luminosity ranging from 5 up to 7.5$\times10^{34}$\,cm$^{-2}$s$^{-1}$. The ambitious goal of the High Luminosity LHC is to achieve a total of 3000--4000\,fb$^{-1}$ of proton-proton collisions at a center-of-mass energy of 14\,TeV. To cope with such challenging environmental conditions, the outer tracker of the CMS experiment will be upgraded using closely spaced silicon sensors (pixels and strips) to provide tracking information at the Level-1 trigger. A PS-Module, composed of both a pixel and a strip sensor, was tested at the Fermilab Test-Beam Facility to evaluate its ability to provide accurate tracking information, particle momentum discrimination capabilities and optimal performance at the irradiation levels expected after being exposed to the harsh conditions of the High Luminosity LHC. The results of the test and the comparison of the module performance before and after irradiation will be presented in this poster.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Analysis of Phase 2 Tracker Upgrade PS Module Before and After Irradiation

The Large Hadron Collider will undergo a luminosity upgrade targeting a peak instantaneous luminosity ranging from 5 up to 7.5$\times10^{34}$\,cm$^{-2}$s$^{-1}$. The ambitious goal of the High Luminosity LHC is to achieve a total of 3000--4000\,fb$^{-1}$ of proton-proton collisions at a center-of-mass energy of 14\,TeV. To cope with such challenging environmental conditions, the outer tracker of the CMS experiment will be upgraded using closely spaced silicon sensors (pixels and strips) to provide tracking information at the Level-1 trigger. A PS-Module, composed of both a pixel and a strip sensor, was tested at the Fermilab Test-Beam Facility to evaluate its ability to provide accurate tracking information, particle momentum discrimination capabilities and optimal performance at the irradiation levels expected after being exposed to the harsh conditions of the High Luminosity LHC. The results of the test and the comparison of the module performance before and after irradiation will be presented in this poster.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Slow control and TDAQ systems installation and tests in the Mu2e experiment

The Mu2e experiment at Fermilab will attempt to detect a coherent neutrinoless conversion of a muon into an electron in the field of an aluminum nucleus, with a sensitivity that is 10,000 times greater than existing limits. The Mu2e trigger and data acquisition system (TDAQ) uses the otsdaqframework as its online Data Acquisition System (DAQ) solution. Developed at Fermilab, otsdaq integrates several components, such as an artdaq-based DAQ, an art-based event processing, and an EPICS-based detector control system (DCS), and provides a uniform multi-user interface toits components through a web browser. The data streams from the Mu2e tracker and calorimeter are handled by the artdaq-based DAQ and processed by a one-level software trigger implemented within the art framework. Events accepted by the trigger have their data combined, post-trigger, with the separately read-out data from the Mu2e Cosmic Ray Veto system. The foundation of Mu2e DCS, EPICS, an Experimental Physics and Industrial Control System, is an open-source platform for monitoring, controlling, alarming, and archiving. Over the last three years, a prototype ofthe TDAQ and DCS systems has been built and tested at Fermilab’s Feynman Computing Center.Currently, the production system installation is underway. At the end, this work presents a brief update on the installation of racks and DAQ hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data acquisition and slow control interface for the Mu2e experiment

The Mu2e experiment at the Fermilab Muon Campus will search for the coherent neutrinoless conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement by a factor of 10000 over existing limits. The Mu2e Trigger and Data Acquisition System (TDAQ) uses otsdaq as the online Data Acquisition System (DAQ) solution. Developed at Fermilab, otsdaq integrates both the artdaq DAQ and the art analysis frameworks for event transfer, filtering, and processing. otsdaq is an online DAQ software suite with a focus on flexibility and scalability and provides a multi-user, web-based, interface accessible through a web browser. The data stream from the detector subsystems is read by a software filter algorithm that selects events which are combined with the data flux coming from a cosmic ray veto system. The Detector Control System (DCS) has been developed using the Experimental Physics and Industrial Control System (EPICS) open source platform for monitoring, controlling, alarming, and archiving. The DCS system has been integrated into otsdaq. A prototype of the TDAQ and the DCS systems has been built at Fermilab's Feynman Computing Center. In this study, we report on the progress of the integration of this prototype in the online otsdaq software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test beam study of SiPM-on-tile configurations

Light yield and spatial uniformity for a large variety of configurations of scintillator tiles were studied. The light from each scintillator was collected by a Silicon Photomultiplier (SiPM) directly viewing the produced scintillation light (SiPM-on-tile technique). The varied parameters included tile transverse size, tile thickness, tile wrapping material, scintillator composition, and SiPM model. Furthermore, these studies were performed using 120 GeV protons at the Fermilab Test Beam Facility. External tracking allowed the position of each proton penetrating a tile to be measured. The results were compared to a GEANT4 simulation of each configuration of scinitillator, wrapping, and SiPM.

47 OTHER INSTRUMENTATION↗

Prototype Data Acquisition and Slow Control Systems for the Mu2e Experiment

The Mu2e experiment at the Fermilab Muon Campus will search for the coherent neutrinoless conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement by a factor of 10 000 over existing limits. Such a charged lepton flavor-violating reaction probes new physics at a scale unavailable with direct searches at either present or planned high-energy colliders. The Mu2e Trigger and Data Acquisition (TDAQ) system exploits otsdaq as its online Data Acquisition System (DAQ) solution. Furthermore, developed at Fermilab, otsdaq integrates both the artdaq DAQ and the art analysis frameworks for event transfer, filtering, and processing. otsdaq is an online DAQ software suite with a focus on flexibility and scalability and provides a multi-user, web-based, interface accessible through a web browser. The read out controllers (ROCs) stream out zero-suppressed data continuously from the detector subsystems to the data transfer controllers (DTCs). The data stream is then read over the peripheral component interconnect express (PCIe) bus to a software filter algorithm that selects events which are combined with the data flux coming from a cosmic-ray veto (CRV) system. The detector control system (DCS) has been developed using the experimental physics and industrial control system (EPICS) open source platform for monitoring, controlling, alarming, and archiving. The DCS has been integrated into otsdaq. A prototype of the TDAQ system and the DCS has been built at Fermilab's Feynman Computing Center. In this article, we report on the progress of the integration of this prototype in the online otsdaq software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trigger-DAQ and Slow Controls Systems in the Mu2e Experiment

The muon campus program at Fermilab includes the Mu2e experiment that will search for a charged-lepton flavor violating processes where a negative muon converts into an electron in the field of an aluminum nucleus, improving by four orders of magnitude the search sensitivity reached so far. Mu2e's Trigger and Data Acquisition System (TDAQ) uses otsdaq as its solution. Developed at Fermilab, otsdaq uses the artdaq DAQ framework and art analysis framework, under the-hood, for event transfer, filtering, and processing. otsdaq is an online DAQ software suite with a focus on flexibility and scalability, while providing a multi-user, web-based, interface accessible through the Chrome or Firefox web browser. The detector Read Out Controller (ROC), from the tracker and calorimeter, stream out zero-suppressed data continuously to the Data Transfer Controller (DTC). Data is then read over the PCIe bus to a software filter algorithm that selects events which are finally combined with the data flux that comes froma Cosmic Ray Ve to System (CRV). A Detector Control System (DCS) for monitoring, controlling, alarming, and archiving has been developed using the Experimental Physics and Industrial Control System (EPICS) Open Source Platform. The DCS System has also been itegrated into otsdaq. The installation of the TDAQ and the DCS systems in the Mu2e building is planned for 2021-2022, and a prototype has been built at Fermilab's Feynman Computing Center. We report here on the developments and achievements of the integration of Mu2e's DCS system into the online otsdaq software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermilab Test Beam Facility Annual Report: FY19

This Technical Memorandum (TM) summarizes the Fermilab Test Beam Faciltiy (FTBF) operations for FY2019. It is one of a series of annual publications intended to gather information in one place. This TM discusses the experiments performed at the Test Beam from November 2018 to July 2019. The experiments are listed in Table 1. Each experiment wrote a summary that was edited for clarity and is included in this report.

43 PARTICLE ACCELERATORS↗

R&D for new silicon pixel sensors for the High Luminosity phase of the CMS experiment at LHC

The High Luminosity upgrade of the CERN LHC collider (HL-LHC) demands a new high-radiation–tolerant solid-state pixel sensor capable of surviving fluencies up to a few 10$^{16} n_{eq}/\mathrm{cm}^2$ at ~ 3 cm from the interaction point. To this extent the INFN ATLAS-CMS joint research activity, in collaboration with Fondazione Bruno Kessler (FBK), is aiming at the development of thin n -in- p –type pixel sensors for the HL-LHC. The R&D covers both planar and single-sided 3D columnar pixel devices made with the Si-Si Direct Wafer Bonding technique, which allows for the production of sensors with 100 μm and 130 μm active thickness for planar sensors, and 130 μm for 3D sensors, the thinnest ones ever produced so far. The first prototypes of hybrid modules, bump-bonded to the present CMS readout chip, have been tested on beam. The first results on their performance before and after irradiation are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test Beam Analysis of Silicon Microstrip Module with Transverse Momentum Discrimination for CMS HL-LHC

The front end chip of the 2S modules (CBC) is capable of reconstructing short track segments correlating the hits of the two closely spaced silicon microstrip sensors constituting a module. These track segments can be used at the level 1 trigger to reconstruct complete tracks with a transverse momentum above 2 GeV/c keeping the trigger selection discrimination very efficient. A prototype mini-module was produced with the latest CBC version and tested before and after irradiation at the Fermilab Test Beam Facility (FTBF) during 3 test-beam campaigns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The INFN R&D: New pixel detector for the High Luminosity upgrade of the LHC

The High Luminosity upgrade of the CERN-LHC (HL-LHC) demands for a new high-radiation tolerant solid-state pixel sensor capable of surviving fluencies up to a few 10 16 particles/cm 2 at ~3 cm from the interaction point. To this extent the INFN ATLAS-CMS joint research activity, in collaboration with Fondazione Bruno Kessler-FBK, is aiming at the development of thin n-in-p type pixel sensors for the HL-LHC. The R&D covers both planar and single-sided 3D columnar pixel devices made with the Si-Si Direct Wafer Bonding technique, which allows for the production of sensors with 100 μm and 130 μm active thickness for planar sensors, and 130 μm for 3D sensors, the thinnest ones ever produced so far. The first prototypes of hybrid modules bump-bonded to the present CMS and ATLAS readout chips have been tested in beam tests. Furthermore, the preliminary results on their performance before and after irradiation are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of uniformity of 50 μ m low-gain avalanche detectors at the Fermilab test beam

In this study, we report measurements of the uniformity of time resolution, signal amplitude, and charged particle detection efficiency across the sensor surface of low-gain avalanche detectors (LGAD). Comparisons of the performance of sensors with different doping concentrations and different active thicknesses are presented, as well as their temperature dependence and radiation tolerance up to 6 x 10 14 n/cm 2 . Results were obtained at the Fermilab test beam facility using 120 GeV proton beams, and a high precision pixel tracking detector. LGAD sensors manufactured by the Centro Nacional de Microelectrónica (CNM) and Hamamatsu Photonics (HPK) were studied. The uniformity of the sensor response in pulse height before irradiation was found to have a 2% spread. The signal detection efficiency and timing resolution in the sensitive areas before irradiation were found to be 100% and 30–40 ps, respectively. A “no-response” area between pads was measured to be about 130 μm for CNM and 170μm for HPK sensors. After a neutron fluence of 6 x 10 14 n/cm 2 the CNM sensor exhibits a large gain variation of up to a factor of 2.5 when comparing metalized and non-metalized sensor areas. An irradiated CNM sensor achieved a time resolution of 30 ps for the metalized area and 40 ps for the non-metalized area, while a HPK sensor irradiated to the same fluence achieved a 30 ps time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermilab Test Beam Facility Annual Report FY17

This Technical Memorandum (TM) summarizes the Fermilab Test Beam operations for FY2017. It is one of a series of annual publications intended to gather information in one place. In this case, the information concerns the individual experiments that ran at FTBF and are listed in Table 1. Each experiment section was prepared by the relevant authors, and was edited for inclusion in this summary.

43 PARTICLE ACCELERATORS↗

Pixel Detector Developments for Tracker Upgrades of the High Luminosity LHC

This paper reports on the INFN (Istituto Nazionale di Fisica Nucleare, Italy) research activity in collaboration with FBK foundry, which is aiming at the development of new pixel detectors for the LHC Phase-2 upgrades. The R&D covers both planar pixel devices and 3D detectors built using columnar technology. All sensors are low thickness n-in-p type, as this is the general direction envisaged for the High Luminosity LHC pixel detector upgrades. Hybrid modules with 100 $\upmu $ m and 130 $\upmu $ m active thickness, connected to the PSI46dig readout chip, have been tested on beam test experiments. Selected preliminary results from test beams are described for both planar and 3D devices. The results on the 3D pixel sensors before irradiation are very satisfactory and support the conclusion that columnar devices are very good candidates for the inner layers of the upgrade pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laboratory and testbeam results for thin and epitaxial planar sensors for HL-LHC

The High-Luminosity LHC (HL-LHC) upgrade of the CMS pixel detector will require the development of novel pixel sensors which can withstand the increase in instantaneous luminosity to L = 5 × 10 34 cm –2 s –1 and collect ~ 3000fb –1 of data. The innermost layer of the pixel detector will be exposed to doses of about 10 16 n eq / cm 2 . Hence, new pixel sensors with improved radiation hardness need to be investigated. A variety of silicon materials (Float-zone, Magnetic Czochralski and Epitaxially grown silicon), with thicknesses from 50 μm to 320 μm in p-type and n-type substrates have been fabricated using single-sided processing. The effect of reducing the sensor active thickness to improve radiation hardness by using various techniques (deep diffusion, wafer thinning, or growing epitaxial silicon on a handle wafer) has been studied. Furthermore, the results for electrical characterization, charge collection efficiency, and position resolution of various n-on-p pixel sensors with different substrates and different pixel geometries (different bias dot gaps and pixel implant sizes) will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I Bubble Chamber

Here, we measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF 3 I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel telescope and the reconstructed scattering angle provides a measure of the nuclear recoil kinetic energy. The bubble chamber was operated with a nominal threshold of (13.6±0.6) keV. Interpretation of the results depends on the response to fluorine and carbon recoils, but in general we find agreement with the predictions of the classical bubble-nucleation theory. Moreover, this measurement confirms the applicability of CF 3 I as a target for spin-independent dark matter interactions and represents a novel technique for calibration of superheated fluid detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗