Search NASA⌕ Search

Engineering topics

Valdes, Alfonso

Publications and source records attributed to Valdes, Alfonso.

Alerga: Alert Aggregation and Reasoning in GOOSE Simulation Pipeline

IEC 61850 specifies the Generic Object Oriented Substation Event (GOOSE) protocol as one option for low latency communication of substation-related events. Due to its strict timing requirements, GOOSE lacks any form of encryption or authentication and has only minimal integrity guarantees. These absences render the protocol vulnerable to a variety of communication anomalies, including adversarial action. In particular, an adversary with access to the substation network can launch man in the middle (MITM) attacks. We propose Alerga, a set of tools to allow operators to mitigate some of the risks of the protocol while retaining its strengths. To that end, we have developed first a GOOSE simulation pipeline including data generation, anomaly detection, alert handling, causal reasoning and data visualization components. The simulator is designed to be modular, allowing operators to swap components to better fit their network capabilities. The volume of alert traffic on a substation network threatens operators with alert fatigue. In order to combat this, we secondly present a novel form of alert aggregation and processing, offering operators a condensed view of any threats to the system. Thirdly, to facilitate the handling of these threats, our causal reasoning system traces the alerts back to their most likely cause, generating an initial hypothesis for operators to investigate.

alert aggregation↗

A Localized Cyber Threat Mitigation Approach For Wide Area Control of FACTS

We propose a localized oscillation amplitude monitoring (OAM) method for the mitigation of cyber threats directed at the wide area control (WAC) system used to coordinate control of Flexible AC Transmission Systems (FACTS) for power oscillation damping (POD) of active power flow on inter-area tie lines. The method involves monitoring the inter-area tie line active power oscillation amplitude over a sliding window. We use system instability - inferred from oscillation amplitudes growing instead of damping - as evidence of an indication of a malfunction in the WAC of FACTS, possibly indicative of a cyber attack. Monitoring the presence of such a growth allows us to determine whether any destabilizing behaviors appear after the WAC system engages to control the POD. If the WAC signal increases the oscillation amplitude over time, thereby diminishing the POD performance, the FACTS falls back to POD using local measurements. The proposed method does not require an expansive system-wide view of the network. We simulate replay, control integrity, and timing attacks for a test system and present results that demonstrate the performance of the OAM method for mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Cyber Threat Mitigation Approach For Wide Area Control of SVCs using Stability Monitoring

We propose a stability monitoring approach for the mitigation of cyber threats directed at the wide area control (WAC) system used for coordinated control of Flexible AC Transmission Systems (FACTS) used for power oscillation damping (POD) of active power flow on inter-area tie lines. The approach involves monitoring the modes of the active power oscillation on an inter-area tie line using the Matrix Pencil (MP) method. We use the stability characteristics of the observed modes as a proxy for the presence of destabilizing cyber threats. We monitor the system modes to determine whether any destabilizing modes appear after the WAC system engages to control the POD. If the WAC signal exacerbates the POD performance, the FACTS falls back to POD using local measurements. The proposed approach does not require an expansive system-wide view of the network. We simulate replay, control integrity, and timing attacks for a test system and present results that demonstrate the performance of the SM approach for mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability Impact of IEEE 1547 Operational Mode Changes Under High DER Penetration in the Presence of Cyber Adversary

The IEEE 1547 standard addresses the integration of Distributed Energy Resources (DER) into Area Electric Power Systems (AEPS). The updated standard, released in 2018 with revisions ongoing, specifies the need for more flexible settings, requiring the DER to remain connected during certain disturbances and provide voltage support via active and reactive power modes. With these increased capabilities comes increased risks, and our analysis of the standard has produced potential settings combinations, which, while allowable under the standard, may actually create instability. This contradicts the main purpose of the revised standard. Since the DER must support a communication interface through which the AEPS operator can change settings, adversarial mode changes are possible via a cyberattack. This concern is heightened as DER penetration increases, where under a reasonable threat model, an attacker could affect multiple DER simultaneously. We have conducted a simulation analysis of potentially adverse combinations of mode change and ridethrough parameters on a hypothetical AEPS with varying degrees of DER penetration. We conclude that certain adverse mode changes, whether through error or cyberattack, can lead to unstable conditions with DER penetrations as low as 24% of the AEPS system capacity.

24 POWER TRANSMISSION AND DISTRIBUTION↗