Search NASASearch

Engineering topics

Van Geet, Otto

Publications and source records attributed to Van Geet, Otto.

Solar Photovoltaic (PV) Damage Assessment After Typhoon Mawar: Findings and Recommendations for Resilient PV on Guam

A team from the National Renewable Energy Laboratory (NREL) visited Guam in August 2023 to assess failure modes of solar photovoltaic (PV) systems after Typhoon Mawar and to provide recommendations to increase the resilience of PV systems on Guam. The team visited 30 systems: commercial and utility scale, and rooftop and ground-mounted. The team observed systems with no apparent damage, as well as systems that were completely lost. Systems fared very well overall. The average failure rate of rooftop systems was 18%, with a median failure rate of 2%, meaning the few systems that suffered total loss pulled up the average. Only eight 8 of the 25 rooftop systems suffered more than 5% damage. All ground-mounted systems suffered less than 0.5% damage, aside from a carport that lost 16% of its modules. PV systems at Andersen Air Force Base suffered 5% damage on average, with a median system failure of 0.6%. In almost all cases, failures were the result of: (1) Inadequate clamping of the module frame to the mount, (2) Module mounting clamps rotating out of underlying support rail (i.e., T-bolt that rotates free at less than 60 degrees of rotation), (3) An object hitting the panel resulting in a fracture, and in some cases leading to a cascading failure of several more panels, and (4) Excessive tilt angle (in Guam, greater than 5 degrees can be a risk due to wind speed, and power production trade-offs are insignificant).

14 SOLAR ENERGY

Tackling the Giants: Applying Smart Labs Principles to Constant Air Volume Lab Buildings

Laboratories typically consume 3 to 10 times more energy than similarly sized commercial buildings, and as much as 50% of that energy is wasted by inefficient and poorly operating fume hoods and ventilation systems. One challenge faced by older laboratory buildings is the heating, ventilation, and air-conditioning systems serving many of these buildings. The older systems are usually constant air volume (CAV) systems that maintain constant ventilation rates that cause excess airflow and inefficient energy use. Variable air volume systems can be more efficient systems with sensors to detect the need for a change in volumetric flow rate; however; renovation of ventilation systems can create disruption to ongoing research and operations along with considerable up-front costs. When a Smart Labs program is implemented, an organization has a systems-based management approach that yields a high-performing laboratory building. As decarbonization continues as a priority for sites, buildings with CAV systems are difficult to address. This work centers around practical guidance for improving lab buildings with CAV. In conjunction with industry input on top technology solutions and best practices, recommendations will include performing a laboratory ventilation risk assessment in conjunction with robust retro-commissioning work, which is a crucial step in the Smart Lab process. By applying Smart Labs principles, the aging laboratory building stock of 153,343 (Lawrence Berkeley National Laboratory [LBNL] 2017), comprising roughly 500,000 lab spaces in the United States, can be brought to safe and high-performance operations.

building

Antigua and Barbuda Distributed Energy Resources Deployment Guidelines

This document is designed to provide comprehensive considerations, best practices and guidance for deployment of Distributed Energy Resources (DERs) in Antigua and Barbuda. The document provides lists of various technology selection guidance including technical specifications, requirements and applicable key standards and code associated with key DERs and balance of plant equipment. The document also presents the key microgrid design considerations to integrate the DERs to achieve the economic, decarbonization and resiliency goals. Taking into account sensitive grid for such islands, for grid readiness and screening the potential DER interconnection, general approach is highlighted along with the potential technical interconnection requirements. Furthermore, this document shows the key stakeholders involved in such DER integration and/or microgrid project and how key responsible project team can be qualified. Finally, this document refers to key information about warranties and consumer rights and maintenance of the systems.

24 POWER TRANSMISSION AND DISTRIBUTION

Best Practices Guide for Energy-Efficient Data Center Design

This guide provides an overview of best practices for energy-efficient data center design which spans the categories of information technology (IT) systems and their environmental conditions, data center air management, cooling and electrical systems, and heat recovery. IT system energy efficiency and environmental conditions are presented first because measures taken in these areas have a cascading effect of secondary energy savings for the mechanical and electrical systems. This guide concludes with a section on metrics and benchmarking values by which a data center and its systems energy efficiency can be evaluated. No design guide can offer “the most energy-efficient” data center design but the guidelines that follow offer suggestions that provide efficiency benefits for a wide variety of data center scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY