Search NASA⌕ Search

Engineering topics

Vapiwala, Neha

Publications and source records attributed to Vapiwala, Neha.

At least 19 records

Phase 1 Trial of Everolimus and Radiation Therapy for Salvage Treatment of Biochemical Recurrence in Prostate Cancer Patients Following Prostatectomy

Purpose: In up to half of patients treated with salvage radiation therapy (SRT) for rising prostate-specific antigen levels, a second biochemical recurrence ultimately develops. Phosphatase and tensin homolog inactivation is implicated in prostate cancer progression, and upregulation of the mammalian target of rapamycin pathway can lead to tumor hypoxia and radioresistance. Everolimus is a mammalian target of rapamycin inhibitor with both antitumor and radiosensitizing effects. Methods and Materials: We performed a phase 1 study using a modified 3 + 3 dose-escalation design to evaluate the safety and tolerability of everolimus in combination with standard SRT for the treatment of biochemical recurrence following prostatectomy. After a 2-week run-in period of everolimus daily therapy, patients received prostate bed irradiation with daily cone beam computed tomography localization in 37 fractions of 1.8 Gy each (total dose, 66.6 Gy). Patients were monitored for both acute (≤90 days) and chronic (>90 days) treatment-related toxicities. Results: Eighteen patients received everolimus at dose levels of 5 mg (n=6), 7.5 mg (n=6), or 10 mg (n=6) daily in conjunction with SRT. No dose-limiting toxicities were observed. Common acute treatment-related toxicities included grade 1 or 2 mucositis (55.6%), grade 1 or 2 fatigue (38.9%), grade 1 or 2 rash (61.1%), and grade 1 urinary symptoms (61.1%). A grade 3 acute toxicity occurred in 4 patients (22.2%) (n=1 for rash, anemia, lymphopenia, and neutropenia), and no patients had a chronic toxicity of grade 3 or greater. After a median follow-up time of 17.8 months (range, 1.2-46.0 months), an undetectable prostate-specific antigen nadir was achieved in 9 patients (56.3%) and a second biochemical recurrence developed in 5 patients (31.3%). Conclusions: Everolimus at a dose of ≤10 mg daily appears to be safe and tolerable in combination with fractionated post-prostatectomy radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Grade Inflation in Medical Student Radiation Oncology Clerkships: Missed Opportunities for Feedback?

Purpose: To test the hypothesis that medical student radiation oncology elective rotation grades are inflated and cannot be used to distinguish residency applicants. Methods and Materials: The records of 196 applicants to a single radiation oncology residency program in 2011 and 2012 were retrospectively reviewed. The grades for each rotation in radiation oncology were collected and converted to a standardized 4-point grading scale (honors, high pass, pass, fail). Pass/fail grades were scored as not applicable. The primary study endpoint was to compare the distribution of applicants' grades in radiation oncology with their grades in medicine, surgery, pediatrics, and obstetrics/gynecology core clerkships. Results: The mean United States Medical Licensing Examination Step 1 score of the applicants was 237 (range, 188-269), 43% had additional Masters or PhD degrees, and 74% had at least 1 publication. Twenty-nine applicants were graded for radiation oncology rotations on a pass/fail basis and were excluded from the final analysis. Of the remaining applicants (n=167), 80% received the highest possible grade for their radiation oncology rotations. Grades in radiation oncology were significantly higher than each of the other 4 clerkships studied (P<.001). Of all applicants, 195 of 196 matched into a radiation oncology residency. Higher grades in radiation oncology were associated with significantly higher grades in the pediatrics core clerkship (P=.002). However, other medical school performance metrics were not significantly associated with higher grades in radiation oncology. Conclusions: Although our study group consists of a selected group of radiation oncology applicants, their grades in radiation oncology clerkships were highly skewed toward the highest grades when compared with grades in other core clerkships. Student grading in radiation oncology clerkships should be re-evaluated to incorporate more objective and detailed performance metrics to allow for meaningful feedback to trainees and to better evaluate residency applicants to radiation oncology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linear Energy Transfer Painting With Proton Therapy: A Means of Reducing Radiation Doses With Equivalent Clinical Effectiveness

Purpose: The purpose of this study was to propose a proton treatment planning method that trades physical dose (D) for dose-averaged linear energy transfer (LET{sub d}) while keeping the radiobiologically weighted dose (D{sub RBE}) to the target the same. Methods and Materials: The target is painted with LET{sub d} by using 2, 4, and 7 fields aimed at the proximal segment of the target (split target planning [STP]). As the LET{sub d} within the target increases with increasing number of fields, D decreases to maintain the D{sub RBE} the same as the conventional treatment planning method by using beams treating the full target (full target planning [FTP]). Results: The LET{sub d} increased 61% for 2-field STP (2STP) compared to FTP, 72% for 4STP, and 82% for 7STP inside the target. This increase in LET{sub d} led to a decrease of D with 5.3 ± 0.6 Gy for 2STP, 4.4 ± 0.7 Gy for 4STP, and 5.3 ± 1.1 Gy for 7STP, keeping the DRBE at 90% of the volume (DRBE, 90) constant to FTP. Conclusions: LET{sub d} painting offers a method to reduce prescribed dose at no cost to the biological effectiveness of the treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adjuvant radiation therapy for bladder cancer: A dosimetric comparison of techniques

Trials of adjuvant radiation after cystectomy are under development. There are no studies comparing radiation techniques to inform trial design. This study assesses the effect on bowel and rectal dose of 3 different modalities treating 2 proposed alternative clinical target volumes (CTVs). Contours of the bowel, rectum, CTV-pelvic sidewall (common/internal/external iliac and obturator nodes), and CTV-comprehensive (CTV-pelvic sidewall plus cystectomy bed and presacral regions) were drawn on simulation images of 7 post-cystectomy patients. We optimized 3-dimensional conformal radiation (3-D), intensity-modulated radiation (IMRT), and single-field uniform dose (SFUD) scanning proton plans for each CTV. Mixed models regression was used to compare plans for bowel and rectal volumes exposed to 35% (V{sub 35%}), 65% (V{sub 65%}), and 95% (V{sub 95%}) of the prescribed dose. For any given treatment modality, treating the larger CTV-comprehensive volume compared with treating only the CTV-pelvic sidewall nodes significantly increased rectal dose (V{sub 35%} {sub rectum}, V{sub 65%} {sub rectum}, and V{sub 95%} {sub rectum}; p < 0.001 for all comparisons), but it did not produce significant differences in bowel dose (V{sub 95%} {sub bowel}, V{sub 65%} {sub bowel}, or V{sub 35%} {sub bowel}). The 3-D plans, compared with both the IMRT and the SFUD plans, had a significantly greater V{sub 65%} {sub bowel} and V{sub 95%} {sub bowel} for each proposed CTV (p < 0.001 for all comparisons). The effect of treatment modality on rectal dosimetry differed by CTV, but it generally favored the IMRT and the SFUD plans over the 3-D plans. Comparison of the IMRT plan vs the SFUD plan yielded mixed results with no consistent advantage for the SFUD plan over the IMRT plan. Targeting a CTV that spares the cystectomy bed and presacral region may marginally improve rectal toxicity but would not be expected to improve the bowel toxicity associated with any given modality of adjuvant radiation. Using the IMRT or the SFUD plans instead of the 3-D conformal plan may improve both bowel and rectal toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact of Intrafraction and Residual Interfraction Effect on Prostate Proton Pencil Beam Scanning

Purpose: To quantitatively evaluate the impact of interplay effect and plan robustness associated with intrafraction and residual interfraction prostate motion for pencil beam scanning proton therapy. Methods and Materials: Ten prostate cancer patients with weekly verification CTs underwent pencil beam scanning with the bilateral single-field uniform dose (SFUD) modality. A typical field had 10-15 energy layers and 500-1000 spots. According to their treatment logs, each layer delivery time was <1 s, with average time to change layers of approximately 8 s. Real-time intrafraction prostate motion was determined from our previously reported prospective study using Calypso beacon transponders. Prostate motion and beam delivering sequence of the worst-case scenario patient were synchronized to calculate the “true” dose received by the prostate. The intrafraction effect was examined by applying the worst-case scenario prostate motion on the planning CT, and the residual interfraction effect was examined on the basis of weekly CT scans. The resultant dose variation of target and critical structures was examined to evaluate the interplay effect. Results: The clinical target volume (CTV) coverage was degraded because of both effects. The CTV D{sub 99} (percentage dose to 99% of the CTV) varied up to 10% relative to the initial plan in individual fractions. However, over the entire course of treatment the total dose degradation of D{sub 99} was 2%-3%, with a standard deviation of <2%. Absolute differences between SFUD, intensity modulate proton therapy, and one-field-per-day SFUD plans were small. The intrafraction effect dominated over the residual interfraction effect for CTV coverage. Mean dose to the anterior rectal wall increased approximately 10% because of combined residual interfraction and intrafraction effects, the interfraction effect being dominant. Conclusions: Both intrafraction and residual interfraction prostate motion degrade CTV coverage within a clinically acceptable level. One-field-per-day SFUD delivered twice is as robust as the bilateral SFUD plan treated daily over the course of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing Interpersonal and Communication Skills in Radiation Oncology Residents: A Pilot Standardized Patient Program

Purpose: There is a lack of data for the structured development and evaluation of communication skills in radiation oncology residency training programs. Effective communication skills are increasingly emphasized by the Accreditation Council for Graduate Medical Education and are critical for a successful clinical practice. We present the design of a novel, pilot standardized patient (SP) program and the evaluation of communication skills among radiation oncology residents. Methods and Materials: Two case scenarios were developed to challenge residents in the delivery of “bad news” to patients: one scenario regarding treatment failure and the other regarding change in treatment plan. Eleven radiation oncology residents paired with 6 faculty participated in this pilot program. Each encounter was scored by the SPs, observing faculty, and residents themselves based on the Kalamazoo guidelines. Results: Overall resident performance ratings were “good” to “excellent,” with faculty assigning statistically significant higher scores and residents assigning lower scores. We found inconsistent inter rater agreement among faculty, residents, and SPs. SP feedback was also valuable in identifying areas of improvement, including more collaborative decision making and less use of medical jargon. Conclusions: The program was well received by residents and faculty and regarded as a valuable educational experience that could be used as an annual feedback tool. Poor inter rater agreement suggests a need for residents and faculty physicians to better calibrate their evaluations to true patient perceptions. High scores from faculty members substantiate the concern that resident evaluations are generally positive and nondiscriminating. Faculty should be encouraged to provide honest and critical feedback to hone residents' interpersonal skills.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Occult Pelvic Lymph Node Involvement in Bladder Cancer: Implications for Definitive Radiation

Purpose: To inform radiation treatment planning for clinically staged, node-negative bladder cancer patients by identifying clinical factors associated with the presence and location of occult pathologic pelvic lymph nodes. Methods and Materials: The records of patients with clinically staged T1-T4N0 urothelial carcinoma of the bladder undergoing radical cystectomy and pelvic lymphadenectomy at a single institution were reviewed. Logistic regression was used to evaluate associations between preoperative clinical variables and occult pathologic pelvic or common iliac lymph nodes. Percentages of patient with involved lymph node regions entirely encompassed within whole bladder (perivesicular nodal region), small pelvic (perivesicular, obturator, internal iliac, and external iliac nodal regions), and extended pelvic clinical target volume (CTV) (small pelvic CTV plus common iliac regions) were calculated. Results: Among 315 eligible patients, 81 (26%) were found to have involved pelvic lymph nodes at the time of surgery, with 38 (12%) having involved common iliac lymph nodes. Risk of occult pathologically involved lymph nodes did not vary with clinical T stage. On multivariate analysis, the presence of lymphovascular invasion (LVI) on preoperative biopsy was significantly associated with occult pelvic nodal involvement (odds ratio 3.740, 95% confidence interval 1.865-7.499, P<.001) and marginally associated with occult common iliac nodal involvement (odds ratio 2.307, 95% confidence interval 0.978-5.441, P=.056). The percentages of patients with involved lymph node regions entirely encompassed by whole bladder, small pelvic, and extended pelvic CTVs varied with clinical risk factors, ranging from 85.4%, 95.1%, and 100% in non-muscle-invasive patients to 44.7%, 71.1%, and 94.8% in patients with muscle-invasive disease and biopsy LVI. Conclusions: Occult pelvic lymph node rates are substantial for all clinical subgroups, especially patients with LVI on biopsy. Extended coverage of pelvic lymph nodes up to the level of the common iliac nodes may be warranted in subsets of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Intrafraction Prostate Motion on Proton Pencil Beam Scanning Delivery: A Quantitative Assessment

Purpose: To assess the dosimetric impact caused by the interplay between intrafraction prostate motion and the intermittent delivery of proton pencil beam scanning (PBS). Methods and Materials: A cohort of 10 prostate patients was treated with PBS using a bilateral single-field uniform dose (SFUD) modality. Bilateral intensity-modulated proton therapy (IMPT) plans were generated for comparison. Because beam-on time in PBS was intermittent, the actual beam-on time was determined from treatment logs. Prostate motion was generalized according to real-time Calypso tracking data from our previously reported prospective photon trial. We investigated potential dose deviations by considering the interplay effect resulting from the worst-case scenario motion and the PBS delivery sequence. Results: For both bilateral-field SFUD and IMPT plans, clinical target volume (CTV) D{sub 99}% coverage was degraded <2% owing to prostate intrafraction motion when averaged over the course of treatment, but was >10% for the worst fraction. The standard deviation of CTV D{sub 99}% distribution was approximately 1.2%. The CTV coverage of individual fields in SFUD plans degraded as time elapsed after the initial alignment, owing to prostate drift. Intensity-modulated proton therapy and SFUD demonstrated comparable results when bilateral opposed fields were used. Single-field SFUD plans that were repainted twice, which could reduce half of the treatment time, resulted in similar CTV coverage as bilateral-field plans. Conclusions: Intrafraction prostate motion affects the actual delivered dose to CTV; however, when averaged over the course of treatment, CTV D{sub 99}% coverage degraded only approximately 2% even for the worst-case scenario. The IMPT plan results are comparable to those of the SFUD plan, and similar coverage can be achieved if treated by SFUD 1 lateral field per day when rescanning the field twice to shorten the treatment time and mitigate intrafraction motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of anterior proton beams in the setting of a prostate-rectum spacer

Studies suggest that anterior beams with in vivo range verification would improve rectal dosimetry in proton therapy for prostate cancer. We investigated whether prostate-rectum spacers would enhance or diminish the benefits of anterior proton beams in these treatments. Twenty milliliters of hydrogel was injected between the prostate and rectum of a cadaver using a transperineal approach. Computed tomography (CT) and magnetic resonance (MR) images were used to generate 7 uniform scanning (US) and 7 single-field uniform dose pencil-beam scanning (PBS) plans with different beam arrangements. Pearson correlations were calculated between rectal, bladder, and femoral head dosimetric outcomes and beam arrangement anterior scores, which characterize the degree to which dose is delivered anteriorly. The overall quality of each plan was compared using a virtual dose-escalation study. For US plans, rectal mean dose was inversely correlated with anterior score, but for PBS plans there was no association between rectal mean dose and anterior score. For both US and PBS plans, full bladder and empty bladder mean doses were correlated with anterior scores. For both US and PBS plans, femoral head mean doses were inversely correlated with anterior score. For US plans and a full bladder, 4 beam arrangements that included an anterior beam tied for the highest maximum prescription dose (MPD). For US plans and an empty bladder, the arrangement with 1 anterior and 2 anterior oblique beams achieved the highest MPD in the virtual dose-escalation study. The dose-escalation study did not differentiate beam arrangements for PBS. All arrangements in the dose-escalation study were limited by bladder constraints except for the arrangement with 2 posterior oblique beams. The benefits of anterior proton beams in the setting of prostate-rectum spacers appear to be proton modality dependent and may not extend to PBS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Discordance Between Preoperative and Postoperative Bladder Cancer Location: Implications for Partial-Bladder Radiation

Purpose: There is strong interest in partial-bladder radiation whether as a boost or definitive therapy to limit long-term toxicity. It is unclear that a standard preoperative examination can accurately identify all sites of disease within the bladder. The purpose of this study was to determine the correlation between preoperative localization of bladder tumors with postoperative findings to facilitate partial-bladder radiation techniques when appropriate. Methods and Materials: We examined patients with clinically staged T1-T4 invasive transitional cell carcinoma (TCC) or TCC with variant histology with no history of radiation or partial cystectomy undergoing radical cystectomy. Patients were scored as “under-detected” if a bladder site was involved with invasive disease (≥T1) at the time of cystectomy, but not identified preoperatively. Patients were additionally scored as “widely under-detected” if they had postoperative lesions that were not identified preoperatively in a given site, nor in any adjacent site. Rates of under-detected and widely under-detected lesions, as well as univariate and multivariate association between clinical variables and under-detection, were evaluated using logistic regression. Results: Among 222 patients, 96% (213/222) had at least 1 area of discordance. Fifty-eight percent of patients were under-detected in at least 1 location, whereas 12% were widely under-detected. Among 24 patients with a single site of disease on preoperative evaluation, 21/24 (88%) had at least 1 under-detected lesion and 14/24 (58%) were widely under-detected. On multivariate analysis, only solitary site of preoperative disease was associated with increased levels of under-detection of invasive disease (OR = 4.161, 95% CI, 1.368-12.657). Conclusion: Our study shows a stark discordance between preoperative and postoperative localization of bladder tumors. From a clinical perspective, incomplete localization of all sites of disease within the bladder may lead to marginal misses when a partial-bladder technique is used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bladder Cancer Patterns of Pelvic Failure: Implications for Adjuvant Radiation Therapy

Purpose: Local-regional failures (LFs) after cystectomy with or without chemotherapy are common in locally advanced disease. Adjuvant radiation therapy (RT) could reduce LFs, but toxicity has discouraged its use. Modern RT techniques with improved normal tissue sparing have rekindled interest but require knowledge of pelvic failure patterns to design treatment volumes. Methods and Materials: Five-year LF rates after radical cystectomy plus pelvic node dissection with or without chemotherapy were determined for 8 pelvic sites among 442 urothelial bladder carcinoma patients. The impact of pathologic stage, margin status, nodal involvement, and extent of node dissection on failure patterns was assessed using competing risk analysis. We calculated the percentage of patients whose sites of LF would have been completely encompassed within various hypothetical clinical target volumes (CTVs) for postoperative radiation. Results: Compared with stage {<=}pT2, stage {>=}pT3 patients had higher 5-year LF rates in virtually all pelvic sites. Among stage {>=}pT3 patients, margin status significantly altered the failure pattern whereas extent of node dissection and nodal positivity did not. In stage {>=}pT3 patients with negative margins, failure occurred predominantly in the iliac/obturator nodes and uncommonly in the cystectomy bed and/or presacral nodes. Of these patients in whom failure subsequently occurred, 76% would have had all LF sites encompassed within CTVs covering only the iliac/obturator nodes. In stage {>=}pT3 with positive margins, cystectomy bed and/or presacral nodal failures increased significantly. Only 57% of such patients had all LF sites within CTVs limited to the iliac/obturator nodes, but including the cystectomy bed and presacral nodes in the CTV when margins were positive increased the percentage of LFs encompassed to 91%. Conclusions: Patterns of failure within the pelvis are summarized to facilitate design of adjuvant RT protocols. These data suggest that RT should target at least the iliac/obturator nodes in stage {>=}pT3 with negative margins; coverage of the presacral nodes and cystectomy bed may be necessary for stage {>=}pT3 with positive margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Physician Communication About Complementary and Alternative Medicine in a Radiation Oncology Setting

Purpose: Despite the extensive use of complementary and alternative medicine (CAM) among cancer patients, patient-physician communication regarding CAM therapies remains limited. This study quantified the extent of patient-physician communication about CAM and identified factors associated with its discussion in radiation therapy (RT) settings. Methods and Materials: We conducted a cross-sectional survey of 305 RT patients at an urban academic cancer center. Patients with different cancer types were recruited in their last week of RT. Participants self-reported their demographic characteristics, health status, CAM use, patient-physician communication regarding CAM, and rationale for/against discussing CAM therapies with physicians. Multivariate logistic regression was used to identify relationships between demographic/clinical variables and patients' discussion of CAM with radiation oncologists. Results: Among the 305 participants, 133 (43.6%) reported using CAM, and only 37 (12.1%) reported discussing CAM therapies with their radiation oncologists. In multivariate analyses, female patients (adjusted odds ratio [AOR] 0.45, 95% confidence interval [CI] 0.21-0.98) and patients with full-time employment (AOR 0.32, 95% CI 0.12-0.81) were less likely to discuss CAM with their radiation oncologists. CAM users (AOR 4.28, 95% CI 1.93-9.53) were more likely to discuss CAM with their radiation oncologists than were non-CAM users. Conclusions: Despite the common use of CAM among oncology patients, discussions regarding these treatments occur rarely in the RT setting, particularly among female and full-time employed patients. Clinicians and patients should incorporate discussions of CAM to guide its appropriate use and to maximize possible benefit while minimizing potential harm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A clinically feasible method for the detection of potential collision in proton therapy

Purpose: Potential collision between the patient/couch and the gantry could delay the start of the treatment and reduce clinical efficiency. The ability to accurately detect possible collisions during the treatment planning phase is desired. Such collision detection should account for the specific proton gantry design, the treatment beam configuration, couch orientation, and the patient specific geometry. In this paper the authors developed an approach to detect possible patient-machine collisions using patient treatment plan data. Methods: The geometry of the machine and the patient was reconstructed relative to the isocenter of the proton treatment room. The surface contour of the gantry was first captured from the proton computer aided design and reconstructed to account for specific gantry rotation, snout position, collimator rotation, and range compensator dimensions based on the patient treatment plan data. The patient body and couch contours were captured from the patient's CT DICOM structure file. They were reconstructed relative to the isocenter taking into account treatment couch rotation. For potential collision that occurs at body portions where no CT images exist, scout images are used to construct the body contour. A software program was developed using a ray casting algorithm that was applied to detect collisions by determining if any of the patient and couch contour points fall into the spatial polygons formed by the proton gantry surfaces. Results: Twenty-four patient plans with or without potential collisions were retrospectively identified and analyzed using the collision detection software. In addition, five collision cases were artificially generated using an anthropomorphic phantom. The program successfully detected the collisions in all cases. The calculation time for each case was within 20 s. The software program was implemented in the authors' clinic to detect patient-gantry or gantry-couch collisions in the treatment planning phase. Conclusions: The authors developed a fast and clinically feasible patient-specific collision detection program for proton therapy based on a ray casting algorithm. If incorporated during the treatment planning phase it may lead to improved clinical efficiency. This methodology could also be applied to patient collision detection in photon therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗