Search NASA⌕ Search

Engineering topics

Vartanian, M. H.

Publications and source records attributed to Vartanian, M. H..

X-ray spectra of young Type I supernova remnants - Exploded white dwarfs?

It is argued that the X-ray spectra of young Type I supernova remnants can be understood consistently in terms of thermal emission mainly from a reverse shock into initially uniform density ejecta. The inferred mass of ejecta is then consistent with 1.4 solar mass in SN 1006, Tycho, and Kepler. A substantial mass of iron, perhaps 0.8 solar mass, may be present provided that the ejecta are chemically inhomogeneous, with iron confined to inner layers of ejecta. The marked difference between the X-ray spectra of SN 1006 and Tycho is explained by the lower interstellar density around SN 1006.

Hamilton, A. J. S.↗

Imaging X-ray spectrophotometric observation of SN 1006

An imaging gas scintillation proportional counter (IGSPC) at the focal plane of a grazing incidence telescope was carried aloft by a sounding rocket and used to observe soft X-ray emission from the supernova remnant SN 1006. The instrument obtained the first unambiguous detection of strong (8 + or 0.0-2 photons/sq cm s) oxygen He-alpha and Ly-alpha emission at 0.59 + or - 0.02 keV from SN 1006. This line emission is consistent with emission from a 1.8 x 10 to the 6th K plasma, although hard X-ray emission from an additional power law or a higher temperature component was also observed. The X-ray emission may be interpreted as due to either (1) a combination of blast-wave and reverse shock assuming equilibrium ionization in the plasma or (2) blast-wave emission alone with a significant degree of ionization disequilibrium.

Vartanian, M. H.↗

A large area imaging gas scintillation proportional counter for use in X-ray astronomy

A large area (200 sq cm), broad bandwidth (0.1-70 keV), imaging gas scintillation proportional counter (IGSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a high pressure xenon gas scintillation proportional counter (GSPC) coupled to a multi-wire proportional counter (MWPC) via a calcium fluoride window. THe MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. The detector has a measured energy resolution of 8.0 percent (FWHM) and 4.3 percent (FWHM) at 5.9 keV and 22.1 keV, respectively. The predicted spatial resolution of the detector is less than 1 mm (FWHM) between 3-22 keV and 37-60 keV. A method to determine the three-dimensional location of detected X-rays is described. In addition, a combination of discrimination schemes designed to reduce the non-X-ray background in the IGSPC by more than two orders of magnitude is discussed.

Ku, W. H.-M.↗

An imaging gas scintillation proportional counter for use in X-ray astronomy

An imaging gas scintillation proportional counter (GSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counter (GSPC) with a 1 micron polypropylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. The MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. The measured energy resolution is 17.0 percent (fwhm) and 8.0 percent (fwhm) at 1.5 keV and 5.9 keV, respectively. The measured position resolution is 1.9 mm (fwhm) and 0.9 mm (fwhm) at 1.5 and 5.9 keV, respectively. Possible astrophysical observations which can be performed with an IGSPC at the focal plane of a grazing incidence telescope are also discussed.

Hailey, C. J.↗

For the detection of subkiloelectron-volt X-rays

A large-area, imaging gas scintillation proportional counter (IGSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counter (GSPC) with a 1-micron polypropylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. The MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. Over a sensitive area of 21 sq cm, the instrument has a measured energy resolution of 17.5% (FWHM) and 1.9 mm (FWHM) spatial resolution at 1.5 keV.

Hailey, C. J.↗

An imaging gas scintillation proportional counter for the detection of subkiloelectron-volt X-rays

A large area imaging gas scintillation proportional counter (IGSPC) was constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counted (GSPC) with a micron polyprotylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. Over a sensitive area of 21 cu cm the instrument has a measured energy resolution of 17.5% (FWHM) and 1.9 mm (FWHM) spatial resolution at 1.5 keV.

Hailey, C. J.↗