Search NASA⌕ Search

Engineering topics

Vasdekis, Andreas E.

Publications and source records attributed to Vasdekis, Andreas E..

At least 19 records

Quantitative phase imaging by gradient retardance optical microscopy

Abstract Quantitative phase imaging (QPI) has become a vital tool in bioimaging, offering precise measurements of wavefront distortion and, thus, of key cellular metabolism metrics, such as dry mass and density. However, only a few QPI applications have been demonstrated in optically thick specimens, where scattering increases background and reduces contrast. Building upon the concept of structured illumination interferometry, we introduce Gradient Retardance Optical Microscopy (GROM) for QPI of both thin and thick samples. GROM transforms any standard Differential Interference Contrast (DIC) microscope into a QPI platform by incorporating a liquid crystal retarder into the illumination path, enabling independent phase-shifting of the DIC microscope's sheared beams. GROM greatly simplifies related configurations, reduces costs, and eradicates energy losses in parallel imaging modalities, such as fluorescence. We successfully tested GROM on a diverse range of specimens, from microbes and red blood cells to optically thick (~ 300 μm) plant roots without fixation or clearing.

47 OTHER INSTRUMENTATION↗

Integrated imaging assembly and method for using

Certain disclosed embodiments concern an integrated imaging system that combined light-sheet microscopy, which enables considerable speed and phototoxicity gains, with quantitative-phase imaging. A method for using such imaging systems also is disclosed. In an exemplary embodiment, an integrated imaging system was used for multivariate investigation of live-cells in microfluidics.

Vasdekis, Andreas E.↗

Scattered–light–sheet microscopy with sub–cellular resolving power

Since its first demonstration over 100 years ago, scattering-based light-sheet microscopy has recently re-emerged as a key modality in label-free tissue imaging and cellular morphometry; however, scattering-based light-sheet imaging with subcellular resolution remains an unmet target to date. This is because related approaches inevitably superimpose speckle or granular intensity modulation on to the native subcellular features. Here, we addressed this challenge by deploying a time-averaged pseudo-thermalized light-sheet illumination. While pseudo-thermalizing the illumination sheet increased its lateral dimensions, we achieved subcellular resolving power at ultralow irradiance levels after image deconvolution. We validated this approach by imaging cytosolic carbon depots in yeast and bacteria with increased specificity and no staining. Altogether, we expect this scattering-based light-sheet microscopy approach will advance live single-cell imaging investigations by conferring low-irradiance and label-free operation towards eradicating phototoxicity.

59 BASIC BIOLOGICAL SCIENCES↗

Video-rate Raman-based metabolic imaging by Airy light-sheet illumination and photon-sparse detection

Despite its massive potential, Raman imaging represents just a modest fraction of all research and clinical microscopy to date. This is due to the ultralow Raman scattering cross-sections of most biomolecules that impose low-light or photon-sparse conditions. Bioimaging under such conditions is suboptimal, as it either results in ultralow frame rates or requires increased levels of irradiance. Here, we overcome this tradeoff by introducing Raman imaging that operates at both video rates and 1,000-fold lower irradiance than state-of-the-art methods. To accomplish this, we deployed a judicially designed Airy light-sheet microscope to efficiently image large specimen regions. Further, we implemented subphoton per pixel image acquisition and reconstruction to confront issues arising from photon sparsity at just millisecond integrations. We demonstrate the versatility of our approach by imaging a variety of samples, including the three-dimensional (3D) metabolic activity of single microbial cells and the underlying cell-to-cell variability. To image such small-scale targets, we again harnessed photon sparsity to increase magnification without a field-of-view penalty, thus, overcoming another key limitation in modern light-sheet microscopy.

60 APPLIED LIFE SCIENCES↗

Raman-probes for monitoring metabolites and nutrient fate in Yarrowia lipolytica using deuterated glucose

The aim of this study was to explore the application of deuterium (D) labeled glucose-D 7 as Raman-tag in Yarrowia lipolytica to assess triacyl glycerides (TAG) biosynthesis. Cells were grown in N depleted media in: (i) glucose in H 2 O (control), (ii) glucose-D 7 in H 2 O and (iii) glucose-D 7 in D 2 O, and the resulting biomass and lipids quantified. Infrared and Raman spectroscopies showed the incorporation of D with the presence of a C-D stretching bands in the silent region (1800–2600 cm -1 ) for cells grown in glucose-D 7 in H 2 O and glucose-D 7 in D 2 O as compared to the control. Fatty acid methyl ester analysis of cells grown in the three media showed significant differences in lipid profiles. Cells grown on glucose-D 7 in H 2 O and glucose-D 7 in D 2 O showed unequivocally D incorporation in fatty acids and TAG by mass spectrometry. Higher D incorporation was observed when cells were grown in D 2 O than H 2 O. Deuterium was also incorporated into the cell wall polysaccharides.

59 BASIC BIOLOGICAL SCIENCES↗

Photon-Sparse, Poisson Light-Sheet Microscopy

Light-sheet microscopy has revolutionized bioimaging by enabling approximately an order of magnitude reduction in specimen irradiance compared to confocal imaging. Here, we introduce a light-sheet imaging system that enables an additional order of magnitude reduction in specimen irradiance by operating at the Poisson limit. To operate at this limit, we integrated classical illumination with single-photon detection and wavelet-based image reconstruction. This integration enabled brightness quantification and object recognition from fewer than one detected photon per image pixel, corresponding to more than 10-fold lower irradiance levels than modern systems. We demonstrate how such photon-sparse imaging can eradicate photobleaching and enable both dim and bright object imaging, thus, further enhancing the related gains of light-sheet microscopy.

60 APPLIED LIFE SCIENCES↗

Optimizing Oil Production in Oleaginous Yeast by Cell-Wide Measurements and Genome-Based Models (Final Report)

The work funded under this DOE genomics grant focused on characterizing, modifying and developing genetic engineering tools for the then very promising but under-characterized oleaginous yeast Yarrowia lipolytica. To-date, all biodiesel production facilities rely on vegetable oils and animal fats as feedstocks, which are very limited. Nature, on the other hand, is very well equipped for making carbohydrates, which are very plentiful throughout the world and rather well distributed in various forms. While numerous (biochemical and thermochemical) technologies exist presently for carbohydrate conversion to alcohols, there is none available for the cost-efficient production of lipids from carbohydrate feedstocks. Such a technology would have wide-ranging implications in land use, renewable resource utilization and production of transportation fuels with minimal carbon footprint. The global research objectives of this award were to develop tools for cell-wide measurement of metabolites and lipids that, along with transcriptional data, will allow the construction of genome-scale metabolic models, as well as models of transcriptional regulation, that will guide the further metabolic engineering of Yarrowia lipolytica. To achieve these goals, a very strong international and diverse team consisting of research groups at MIT, UCLA, PNNL and Chalmers University was put together, whose specific goals, achievements and breakthroughs are included in this report.

10 SYNTHETIC FUELS↗

Deep learning classification of lipid droplets in quantitative phase images

We report the application of supervised machine learning to the automated classification of lipid droplets in label-free, quantitative-phase images. By comparing various machine learning methods commonly used in biomedical imaging and remote sensing, we found convolutional neural networks to outperform others, both quantitatively and qualitatively. We describe our imaging approach, all implemented machine learning methods, and their performance with respect to computational efficiency, required training resources, and relative method performance measured across multiple metrics. Overall, our results indicate that quantitative-phase imaging coupled to machine learning enables accurate lipid droplet classification in single living cells. As such, the present paradigm presents an excellent alternative of the more common fluorescent and Raman imaging modalities by enabling label-free, ultra-low phototoxicity, and deeper insight into the thermodynamics of metabolism of single cells.

59 BASIC BIOLOGICAL SCIENCES↗

Fusing Quantitative-Phase Imaging with Airy Light- Sheet Microscopy

We report the integration of quantitative-phase imaging (QPI) with light-sheet (LS) fluorescent microscopy on to a standard inverted microscope that retains compatibility with microfluidics. QPI enables label-free imaging and number-density quantification of single cells and their organelles. Conversely, LS yields considerable speed and phototoxicity gains in quantifying the 4D dynamics of gene-encoded fluorescent biomarkers. We will detail the system design that relied on spatial light interferometry for QPI and an accelerating Airy- beam light-sheet for fluorescence, its performance, as well as results of a representative multivariate imaging analysis of single-cell metabolism.

imaging, lattice light sheet, Yarrowia lipolytica,↗

Integrative Quantitative-Phase and Airy Light-Sheet Imaging

Light-sheet microscopy enables considerable speed and phototoxicity gains, while quantitative-phase imaging confers label-free organelle recognition and metabolic information that are inaccessible by conventional methods. We report the fusion of these two modalities onto a standard inverted microscope that retains compatibility with microfluidics. We describe the utilization of an accelerating Airy-beam light-sheet yielding identical imaging areas with interferometry, and an application in unmasking the effects of cellular noise on metabolic compartmentalization.

Biological sciences, Biological techniques, Micros↗

Eliciting the impacts of cellular noise on metabolic trade-offs by quantitative mass imaging

Metabolic trade-offs between growth and productivity are key constraints in metabolic engineering and adaptive evolution; however, how cellular noise impacts these trade offs and drives the emergence of subpopulations with distinct resource allocation strategies, remains largely unknown. Here, we introduce a single-cell strategy for quantifying the trade-offs between triacylglycerol production and growth in the oleaginous microorganism Yarrowia lipolytica. The strategy relies on high-throughput quantitative-phase imaging and, enabled by nanoscale secondary ion mass spectrometry analyses and dedicated image processing, allows us to image how resources are partitioned between growth and productivity. Enhanced precision over population-averaging biotechnologies and conventional microscopy demonstrates how cellular noise impacts growth and productivity differently. As such, subpopulations with distinct metabolic trade-offs emerge, with notable impacts on strain performance and robustness. By quantifying autophagic catabolic fluxes under nutrient-limiting conditions, we discover an underlying cell-to-cell heterogeneity in protein and fatty-acid recycling, unmasking a potential bet-hedging survival strategy under starvation.

59 BASIC BIOLOGICAL SCIENCES↗

Mesoscale Polymer Dissolution Probed by Raman Spectroscopy and Molecular Simulations

The diffusion of various solvents into a polystyrene (PS) matrix was probed experimentally by monitoring the temporal profiles of the Raman spectra and theoretically from molecular dynamics (MD) simulations of the binary system. The simulation results assist in providing a fundamental, molecular level connection between the mixing/dissolution processes and the difference = solvent – PS in the values of the Hildebrand parameter () between the two components of the binary systems: solvents having similar values of with PS (small ) exhibit fast diffusion into the polymer matrix, whereas the diffusion slows down considerably when the ’s are different (large ). To this end, the Hildebrand parameter was identified as a useful descriptor that governs the process of mixing in polymer – solvent binary systems. The experiments also provide insight into further refinements of the models specific to non-Fickian diffusion phenomena that need to be used in the simulations.

Chang, Tsun-Mei↗

Review of methods to probe single cell metabolism and bioenergetics

The sampling and manipulation of cells down to the individual has been of substantial interest since the very beginning of Life Sciences. Herein, our objective is to highlight the most recent developments in single cell manipulation, as well as pioneering ones. First, flow-through methods will be discussed, namely methods in which the single cells flow continuously in an ordered manner during their analysis. This section will be followed by confinement techniques that enable cell isolation and confinement in one, two- or three-dimensions. Flow cytometry and droplet microfluidics are the two most common methods of flow-through analysis. While both are high-throughput techniques, their difference lays in the fact that the droplet encapsulated cells experience a restricted and personal microenvironment, while in flow cytometry cells experience similar nutrient and stimuli initial concentrations. These methods are rather well established; however, they recently enabled immense strides in single cell phenotypic analysis, namely the identification and analysis of metabolically distinct individuals from an isogenic population using both droplet microfluidics and flow cytometry.

59 BASIC BIOLOGICAL SCIENCES↗

Solvent Immersion Imprint Lithography

The mechanism of polymer disolution was explored for polymer microsystem prototyping, including microfluidics and optofluidics. Polymer films are immersed in a solvent, imprinted and finally brought into contact with a non-modified surface to permanently bond. The underlying polymer-solvent interactions were experimentally and theoretically investigated, and enabled rapid polymer microsystem prototyping. During imprinting, small molecule integration in the molded surfaces was feasible, a principle applied to oxygen sensing. Polystyrene (PS) was employed for microbiological studies at extreme environmental conditions. The thermophile anaerobe Clostridium Thermocellum was grown in PS pore-scale micromodels, revealing a double mean generation lifetime than under ideal culture conditions. Microsystem prototyping through directed polymer dissolution is simple and accessible, while simultaneous patterning, bonding, and surface/volume functionalization are possible in less than one minute.

Environmental Molecular Sciences Laboratory↗

Optical Manipulation of Vesicles for Optofluidic Applications

In this report, we review our recent results in the optical micromanipulation of vesicles. Traditionally, vesicle manipulation has been possible by employing photon momentum and optical trapping, giving rise to unique observations of vesicle shape changes and soft matter mechanics. Contrary to these attempts, we employ photon energy rather than momentum, by sensitizing vesicles with an oxidizing moiety. The later converts incident photons to reactive oxygen species, which in turn attack and compromise the stability of the vesicle membrane. Both coherent and incoherent radiation was employed. Polymersome re-organization into smaller diameter vesicles was possible by focusing the excitation beam in the vicinity of the polymersomes. Extended vesicle illumination with a collimated beam lead to their complete destabilization and micelle formation. Single particle analysis revealed that payload release takes place within seconds of illumination in an explosive burst. We will discuss the destabilization and payload release kinetics, as revealed by high resolution microscopy at the single particle level, as well as potential applications in single cell biomodulation.

Environmental Molecular Sciences Laboratory↗